Dell™ PowerEdge™ T310 Systems Getting Started With Your System 系统使用入门 Mengaktifkan Sistem Anda はじめに 시스템 시작 안내서
Dell™ PowerEdge™ T310 Systems Getting Started With Your System Regulatory Model E09S Regulatory Type E09S001
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. ____________________ Information in this document is subject to change without notice. © 2009 Dell Inc. All rights reserved.
Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Optional – Connecting the Keyboard, Mouse, and Monitor Connect the keyboard, mouse, and monitor (optional). The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.
Connecting the Power Cable(s) Connect the system’s power cable(s) to the system and, if a monitor is used, connect the monitor’s power cable to the monitor. Securing the Power Cable(s) Bend the system power cable(s) into a loop as shown in the illustration and secure the cable(s) with the provided strap. Plug the other end of the power cable(s) into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
Turning On the System Press the power button on the system and the optional monitor, if used. The power indicators should light. Complete the Operating System Setup If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the installation and configuration documentation for your operating system.
• Microsoft Windows Essential Business Server 2008 Standard and Premium (x64) Editions • Microsoft Windows Server 2003 R2 Standard and Enterprise (x64) Editions with SP2 • Microsoft Windows Server 2003 R2 Standard and Enterprise (x86) Editions with SP2 • Red Hat® Enterprise Linux® ES (Version 5.3) (x86) • Red Hat Enterprise Linux ES (Version 5.
Obtaining Technical Assistance If you do not understand a procedure in this guide or if the system does not perform as expected, see your Hardware Owner’s Manual. Dell™ offers comprehensive hardware training and certification. See www.dell.com/training for more information. This service may not be offered in all locations.
Memory Architecture 800-MHz, 1066-MHz, or 1333-MHz DDR3 registered or unbuffered Error Correcting Code (ECC) DIMMs. Memory module sockets Six 240-pin Memory module capacities 1 GB, 2 GB, 4 GB, or 8 GB Minimum RAM 1 GB Maximum RAM 32 GB Drives Hard drives Up to four 3.5-inch hot-plug SAS or SATA internal drives or Up to four 3.5-inch cabled SAS or SATA internal drives or Up to four 2.5-inch hot-plug SAS or SSD internal drives in a 3.5-inch carrier.
Connectors Back NIC Two RJ-45 (for integrated 1-GB NICs) Serial 9-pin, DTE, 16550-compatible USB Four 4-pin, USB 2.0-compliant Video 15-pin VGA Front USB Two 4-pin, USB 2.0-compliant Internal USB Two 4-pin, USB 2.0-compliant Video Video type Matrox G200, integrated in iDRAC Video memory 8 MB Power AC power supply (per power supply) Wattage 375 W (non-redundant power supply) 400 W (redundant power supply) Voltage 100-240 VAC, 50/60 Hz, 5.8A-2.
Physical Height 44 cm (17.3 inch) Width 21.8 cm (8.6 inch) Depth 52.1 cm (20.5 inch) Weight (maximum configuration) 23.5 kg (51.8 lb) Environmental NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets. Temperature Operating 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.
Environmental (continued) Maximum shock Operating One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms Altitude Operating 0 to 3,048 m (0 to 10,000 ft) NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.
12 Getting Started With Your System
Dell™ PowerEdge™ T310 系统 系统使用入门 管制型号 E09S 管制类型 E09S001
注、小心和警告 注:“注”表示可以帮助您更好地使用计算机的重要信息。 小心:“小心”表示如果不遵循说明,就有可能损坏硬件或导致数据 丢失。 警告: “警告”表示可能会造成财产损失、人身伤害甚至死亡。 ____________________ 本说明文件中的信息如有更改,恕不另行通知。 © 2009 Dell Inc. 版权所有,翻印必究。 未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。 本文中使用的商标:Dell、 DELL 徽标和 PowerEdge 是 Dell Inc. 的商标; Intel 和 Xeon 是 Intel Corporation 在美 国 和其它国家或地区的注册商标; Microsoft、 Windows、 Windows Server 和 Hyper-V 是 Microsoft Corporation 在美国和 / 或其它国家或地区的商标或注册 商标; Red Hat 和 Enterprise Linux 是 Red Hat, Inc. 在美国和 / 或其它国家或地区的注册 商标; SUSE 是 Novell, Inc.
安装和配置 警告:执行下列步骤之前,请阅读系统随附的安全说明。 可选 – 连接键盘、鼠标和显示器 连接键盘、鼠标和显示器(可选)。 系统背面的连接器附有图标,这些图标指示了要插入每个连接器的电缆。 确保拧紧显示器的电缆连接器上的螺钉(如果有)。 系统使用入门 15
连接电源电缆 将系统电源电缆连接至系统,如果使用显示器,将显示器电源电缆连接至显 示器。 固定电源电缆 如图所示,将系统电源电缆弯曲成一个环路,并使用所提供的腕带固定该 电缆。 将电源电缆的另一端插入接地的电源插座或单独的电源,如不间断电源设备 (UPS) 或配电装置 (PDU)。 16 系统使用入门
开启系统 按下系统和显示器(如有使用)上的电源按钮。电源指示灯将会亮起。 完成操作系统安装 如果购买了预安装的操作系统,请参阅随系统提供的操作系统说明文件。 第一次安装操作系统时,请参阅操作系统的安装和配置说明文件。请确保先 安装操作系统,然后再安装未预装的硬件或软件。 支持的操作系统 • Microsoft® Windows® Server 2008 R2 Standard 版和 Enterprise (x64) 版 • Microsoft Windows Server® 2008 Standard 版和 Enterprise (x86) 版 (含 SP2) • Microsoft Windows Server 2008 Standard 版和 Enterprise (x64) 版 • Microsoft Windows Server 2008 Standard 版和 Enterprise (x86) 版 • Microsoft Windows Small Business Server 2008 Standard 版和 Premium (x64) 版 • Microsoft W
• Microsoft Windows Server 2003 R2 Standard 版和 Enterprise (x86) 版 (含 SP2) • Red Hat® Enterprise Linux® ES(第 5.3 版)(x86) • • Red Hat Enterprise Linux ES(第 5.3 版)(x86_64) SUSE® Linux Enterprise Server 11 (x86_64) • Microsoft Windows Server 2008 Hyper-V™ 注:有关支持的操作系统的最新信息,请参阅 www.dell.com。 可能需要的其它信息 警告:请查看系统附带的安全和管制信息。保修信息可能包括在该说明文 件中,也可能作为单独的说明文件提供。 • 《硬件用户手册》提供了有关系统功能的信息,并说明了如何排除系 统故障以及安装或更换系统组件。可在 support.dell.
技术规格 处理器 处理器类型 一个四核 Intel® Xeon® 处理器 扩充总线 总线类型 PCI Express 第 2 代 扩充槽 插槽 1:PCIe x8(x8 布线)半长 插槽 2:PCIe x16(x8 布线)全长 插槽 3:PCIe x8(x4 布线)半长 插槽 4:PCIe x1(x1 布线)半长 插槽 5:PCIe x1(x1 布线)半长 内存 体系结构 800-Mhz、1066-MHz 或 1333-MHz DDR3 已 注册或非缓冲错误纠正代码 (ECC) DIMM。 内存模块插槽 六个 240 针连接器 内存模块容量 1 GB、2 GB、4 GB 或 8 GB 最小 RAM 1 GB 最大 RAM 32 GB 驱动器 硬盘驱动器 至多四个 3.5 英寸热插拔 SAS 或 SATA 内部 驱动器 或 至多四个 3.5 英寸已连接电缆的 SAS 或 SATA 内部驱动器 或 在一个 3.5 英寸托盘中至多四个 2.
连接器 背面 NIC 两个 RJ-45(用于集成的 1 GB NIC) 串行 9 针、DTE、16550 兼容连接器 USB 四个 4 针、USB 2.0 兼容连接器 视频 15 针 VGA 连接器 正面 USB 两个 4 针、USB 2.0 兼容连接器 内部 USB 两个 4 针、USB 2.0 兼容连接器 视频 视频类型 Matrox G200,集成在 iDRAC 中 视频内存 8 MB Power(电源) 交流电源设备(每个电源设备) 功率 375 W(非冗余电源设备) 400 W(冗余电源设备) 电压 100-240 VAC, 50/60 Hz, 5.8A-2.9A 散热 最大 1683 BTU/ 小时(非冗余电源设备) 最大 1672 BTU/ 小时(冗余电源设备) 最大涌入电流 在典型的线路条件下和整个系统运行范 围内,每个电源设备在 10 ms 或更短时间 内的涌入电流可达 25A(冗余电源设备) 和 35A (非冗余电源设备)。 电池 系统电池 20 系统使用入门 CR 2032 3.
物力 高度 44 厘米(17.3 英寸) 宽度 21.8 厘米(8.6 英寸) 厚度 52.1 厘米(20.5 英寸) 重量(最大配置) 23.5 千克(51.8 磅) 环境参数 注:有关特定系统配置的环境测量值的其它信息,请参阅 www.dell.com/environmental_datasheets。 温度 运行时 10° 到 35 °C(50° 到 95 °F),最大温 度变化梯度为每小时 10°C 注:海拔高度在 2950 英尺以上时,最高操 作温度按 1 °F/550 英尺降低。 存储时 – 40° 到 65 °C(– 40° 到 149 °F), 最大温度梯度为每小时 20 °C 相对湿度 运行时 20% 至 80%(非冷凝),最大湿度梯度为 每小时 10% 存储时 20% 至 85%(非冷凝) 最大振动 运行时 在 5 – 500 Hz、0.26 G 时,可持续 15 分钟 存储时 在 10 – 250 Hz、1.
环境参数 (续) 最大撞击 运行时 z 轴正方向上可承受一个 31 G 的撞击脉冲 (系统每一面承受一个脉冲),在操作方 向最多可持续 2.6 毫秒 存储时 x、y 和 z 轴正负方向上可承受连续六个 71 G 的撞击脉冲(系统每一面承受一个 脉冲),最长可持续 2 毫秒 海拔高度 运行时 0 至 3,048 米(0 至 10,000 英尺) 注:海拔高度在 2950 英尺以上时,最高操 作温度按 1 °F/550 英尺降低。 存储时 0 至 10,605 米(– 50 至 35,000 英尺) 气载污染物级别 G2 或更低(根据 ISA-S71.
Dell™ PowerEdge™ T310 Systems Mengaktifkan Sistem Anda Model Regulatori E09S Jenis Regulatori E09S001
Catatan, Perhatian dan Peringatan CATATAN: CATATAN adalah informasi penting yang membantu Anda menggunakan komputer dengan lebih baik. PERHATIAN: PERHATIAN menunjukkan potensi kerusakan perangkat keras atau hilangnya data jika instruksi tidak diikuti. PERINGATAN: PERINGATAN menunjukkan kemungkinkan kerusakan barang, cedera tubuh atau kematian. ____________________ Informasi dalam dokumen ini dapat diubah tanpa pemberitahuan. © 2009 Dell Inc. Hak Cipta Dilindungi Undang-undang.
Instalasi dan Konfigurasi PERINGATAN: Sebelum melakukan prosedur berikut, pelajari instruksi keselamatan yang dikirimkan bersama sistem. Opsional - Menghubungkan Keyboard, Mouse dan Monitor Menghubungkan keyboard, mouse dan monitor (opsional). Konektor di bagian belakang sistem Anda mempunyai ikon yang menyatakan kabel yang mana yang harus dihubungkan ke masing-masing konektor. Pastikan untuk mengencangkan sekrup (jika ada) pada konektor kabel monitor.
Menghubungkan Kabel Daya Hubungkan kabel daya sistem ke sistem dan, jika menggunakan monitor, hubungkan kabel daya monitor ke monitor. Mengunci Kabel Daya Tekuk kabel daya sistem dalam bentuk lingkaran seperti terlihat pada gambar dan kunci kabel dengan tali pengikat yang disediakan. Tancapkan ujung kabel daya yang lain ke stopkontak listrik yang ditanahkan atau sumber daya terpisah seperti catu daya tak terputus (UPS) atau unit distribusi daya (PDU).
Menyalakan Sistem Tekan tombol daya pada sistem dan monitor opsional, jika digunakan. Indikator daya seharusnya menyala. Menyelesaikan Penataan Sistem Operasi Jika Anda membeli sistem operasi yang telah terinstal, lihat dokumentasi sistem operasi yang dikirimkan dengan sistem Anda. Untuk menginstal sistem operasi untuk pertama kalinya, lihat dokumentasi instalasi dan konfigurasi untuk sistem operasi Anda.
• Microsoft Windows Essential Business Server 2008 Edisi Standard dan Premium (x64) • Microsoft Windows Server 2003 R2 Edisi Standard, dan Enterprise (x64) dengan SP2 • Microsoft Windows Server 2003 R2 Edisi Standard dan Enterprise (x86) dengan SP2 • Red Hat® Enterprise Linux® ES (Versi 5.3) (x86) • Red Hat Enterprise Linux ES (Versi 5.
Mendapatkan Bantuan Teknis Jika Anda tidak memahami suatu prosedur dalam panduan ini atau jika sistem tidak bekerja seperti yang diharapkan, lihat Panduan Pemilik Perangkat Keras. Dell™ menyediakan pelatihan dan sertifikasi perangkat lunak yang komprehensif. Lihat www.dell.com/training untuk informasi lebih lanjut. Layanan ini mungkin tidak tersedia di semua lokasi.
Drive Hard drive Sampai dengan empat drive internal 3,5-inci hot-plug SAS atau SATA atau Sampai dengan empat drive internal 3,5-inci SAS atau SATA berkabel atau Sampai dengan empat drive internal 2,5-inci hot-plug SAS atau SATA pada pemuat 3,5inci. Drive optik SATA DVD-ROM atau SATA DVD+/-RW internal opsional USB DVD-ROM eksternal opsional CATATAN: Perangkat DVD hanya data.
Daya Catu daya AC (per catu daya) Watt Daya 375 W (catu daya tanpa cadangan) 400 W (catu daya dengan cadangan) Tegangan 100-240 VAC, 50/60 Hz, 5,8A–2,9A Pelepasan panas 1683 BTU/jam maksimum (catu daya tanpa cadangan) 1672 BTU/jam maksimum (catu daya dengan cadangan) Lonjakan arus maksimum Pada kondisi jaringan listik tipikal dan di seluruh kisaran pengoperasian normal sistem, lonjakan arus dapat mencapai 25 A (catu daya dengan cadangan) dan 35A (catu daya tanpa cadangan) per catu daya selama 10 mdtk
Lingkungan CATATAN: Untuk informasi lebih lanjut mengenai pengukuran lingkungan untuk konfigurasi sistem spesifik, lihat www.dell.com/environmental_datasheets. Suhu Pengoperasian 10° s/d 35°C (50° s/d 95°F) dengan perubahan suhu maksimum 10°C per jam CATATAN: Pada ketinggian di atas 899,16 m (2.950 ft), suhu pengoperasian maksimum berkurang 1°F/167,64 m (550 ft).
Lingkungan (bersambung) Ketinggian Pengoperasian 0 s/d 3.048 m (0 s/d 10.000 kaki) CATATAN: Pada ketinggian di atas 899,16 m (2.950 ft), suhu pengoperasian maksimum berkurang 1°F/167,64 m (550 ft). Penyimpanan 0 s/d 10.605 m (–50 s/d 35.000 kaki) Tingkat Pencemaran Udara Kelas G2 atau yang lebih rendah sesuai standar ISA-S71.
34 Mengaktifkan Sistem Anda
Dell™ PowerEdge™ T310 システム はじめに 認可モデル E09S 認可タイプ E09S001
メモ、注意、警告 メモ:コンピュータを使いやすくするための重要な情報を説明してい ます。 注意:手順に従わない場合は、ハードウェアの損傷やデータの損失の可能 性があることを示しています。 警告: 物的損害、けが、または死亡の原因となる可能性があることを示 しています。 ____________________ 本書の内容は予告なく変更されることがあります。 © 2009 すべての著作権は Dell Inc. にあります。 Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じられてい ます。 本書に使用されている商標: Dell、DELL ロゴ、および PowerEdge は Dell Inc.
取り付けと設定 警告:次の手順を実行する前に、システムに付属しているマニュアルの 安全にお使いいただくための注意事項をお読みください。 オプション – キーボード、マウス、モニターの接続 キーボード、マウス、モニター(オプション)を接続します。 システム背面のコネクタには、どのケーブルを各コネクタに接続するか を示すアイコンがあります。モニターのケーブルコネクタにネジがある 場合は、必ず締めてください。 はじめに 37
電源ケーブルの接続 システムの電源ケーブルをシステムに接続し、モニターを使用する場 合は、モニターの電源ケーブルをモニターに接続します。 電源ケーブルの固定 システムの電源ケーブルをループ状に曲げ(図を参照)、付属のスト ラップで固定します。 電源ケーブルのもう一方の端をアースされた電源コンセントまたは UPS (無停電電源装置)や配電装置(PDU)などの電源に接続します。 38 はじめに
システムの電源投入 システムとオプションのモニター(使用している場合)の電源ボタンを 押します。電源インジケータが点灯します。 OS のセットアップの完了 システムに OS がプリインストールされている場合は、システムに同梱 の OS のマニュアルを参照してください。OS を初めてインストールす る場合は、お使いの OS のインストールと設定に関するマニュアルを参 照してください。システムとは別途に購入したハードウェアやソフト ウェアのインストールは、OS がインストール済みであることを確認し てから行ってください。 対応 OS • Microsoft® Windows® Server 2008 R2 Standard/Enterprise(x64) Edition • Microsoft Windows Server® 2008 Standard/Enterprise(x86) Edition With SP2 • Microsoft Windows Server 2008 Standard/Enterprise(x64) Edition • Microsoft Windows Serv
• • Microsoft Windows Small Business Server 2008 Standard/ Premium(x64)Edition Microsoft Windows Essential Business Server 2008 Standard/Premium(x64)Edition • Microsoft Windows Server 2003 R2 Standard/Enterprise(x64) Edition With SP2 • Microsoft Windows Server 2003 R2 Standard/Enterprise(x86) Edition With SP2 • Red Hat® Enterprise Linux® ES(バージョン 5.3)(x86) • Red Hat Enterprise Linux ES(バージョン 5.
テクニカルサポートの利用法 本書の手順が理解できない場合やシステムが思ったとおりに動作しない 場合は、『ハードウェアオーナーズマニュアル』を参照してください。 デルでは広範囲にわたるハードウェアのトレーニングと資格認証を実施 しています。詳細については、www.dell.
ドライブ ハードドライブ 3.5 インチキャリアにホットプラグ対応の 3.5 インチ SAS または SATA 内蔵ドライブ 4 台まで または ケーブル接続済み 3.5 インチ SAS または SATA 内蔵ドライブ 4 台まで または ホットプラグ対応の 2.5 インチ SAS また は SSD 内蔵ドライブ 4 台まで オプティカルドライブ オプションの内蔵 SATA DVD-ROM または DVD+/-RW オプションの外付け USB DVD-ROM メモ:DVD デバイスはデータ専用。 テープドライブ オプションのハーフハイト内蔵テープ バックアップデバイス 1 台 コネクタ 背面 NIC RJ-45(内蔵 1 GB NIC 用)コネクタ 2 個 シリアル 16550 互換 9 ピン DTE USB 4 ピン USB 2.0 対応コネクタ 4 個 ビデオ 15 ピン VGA 前面 4 ピン USB 2.0 対応コネクタ 2 個 USB 内蔵 4 ピン USB 2.
電源 AC 電源ユニット(各電源ユニットにつき) ワット数 375 W(非冗長電源ユニット) 400 W(冗長電源ユニット) 電圧 100 ~ 240 VAC、50/60 Hz、5.8A ~ 2.9A 熱消費 最大 1683 BTU/ 時(非冗長電源ユニット) 最大 1672 BTU/ 時(冗長電源ユニット) 最大流入電流 通常のラインコンディションのもと、シ ステムの動作環境全範囲で、電源ユニッ ト 1 台に付き 10 ミリ秒以下で 25 A(冗 長電源ユニット)および 35 A(非冗長電 源ユニット)の入電量を許容できます。 バッテリー システムバッテリー 3.0 V コイン型リチウムイオンバッテリー CR 2032 サイズと重量 縦幅 44 cm 横幅 21.8 cm 奥行き 52.1 cm 重量(最大構成) 23.5 kg 環境 メモ:特定のシステム構成でのその他の環境条件の詳細については、 www.dell.
環境 (続き) 相対湿度 動作時 1 時間当たり最大 10 パーセントの湿 度変化で 20 ~ 80 パーセント(結露しな いこと) 保管時 20 ~ 85 パーセント(結露しないこと) 最大耐久震度 動作時 15 分間にわたり 5 ~ 500 Hz で 0.26 G 保管時 15 分間にわたり 10 ~ 250 Hz で 1.54 G 最大耐久衝撃 動作時 z 軸の正方向に 2.6 ミリ秒で 31 G の 1 衝撃パルス(システムの各面に対して 1 パルス) 保管時 x、y、z 軸の正および負方向に 6 連続 衝撃パルス(システムの各面に対し て 1 パルス) 、2 ミリ秒以下で 71 G 高度 動作時 0 ~ 3,048 m メモ:高度が 900 m を超えると、動作時 の許容最大温度は、168 m ごとに 1°F ずつ 低下します。 保管時 0 ~ 10,605 m 空気汚染物質レベル クラス 44 はじめに G2 またはそれ未満(ISA-S71.
Dell™ PowerEdge™ T310 시스템 시스템 시작 안내서 규정 모델 E09S 규정 유형 E09S001
주 , 주의 및 경고 주: 주는 컴퓨터를 보다 효율적으로 사용하는 데 도움을 주는 중요 정보를 제 공합니다. 주의: 주의는 지침을 준수하지 않으면 하드웨어 손상이나 데이터 손실의 위험 이 있음을 알려 줍니다. 경고 : 경고는 재산상의 피해나 심각한 부상 또는 사망을 유발할 수 있는 위험 이 있음을 알려줍니다 . ____________________ 이 문서의 정보는 사전 통보 없이 변경될 수 있습니다. © 2009 Dell Inc. 저작권 본사 소유. Dell Inc.의 서면 승인 없이 어떠한 경우에도 무단 복제하는 것을 엄격히 금합니다. 본 설명서에 사용된 상표인 Dell, DELL 로고 및 PowerEdge는 Dell Inc.의 상표이며, Intel 및 Xeon은 미국 및 기타 국가에서 Intel Corporation의 등록 상표입니다.
설치 및 구성 경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토 하십시오 . 선택 사양 – 키보드 , 마우스 및 모니터 연결 키보드, 마우스 및 모니터(선택 사양)를 연결합니다. 시스템 후면에 있는 커넥터에는 각 커넥터에 연결될 케이블이 표시된 아이 콘이 있습니다. 모니터의 케이블 커넥터에 있는 나사(해당하는 경우)를 단단 히 고정하십시오.
전원 케이블 연결 시스템의 전원 케이블을 시스템에 연결하고, 모니터를 사용하는 경우 모니 터의 전원 케이블을 모니터에 연결합니다. 전원 케이블 고정 그림과 같이 시스템 전원 케이블을 고리 모양으로 구부려서 제공된 끈으로 케이블을 고정합니다. 전원 케이블의 반대쪽 끝을 접지된 전원이나 UPS (Uninterruptible Power Supply) 또는 PDU(Power Distribution Unit)와 같은 별도의 전원에 연결합 니다.
시스템 켜기 시스템과 선택 사양인 모니터(사용되는 경우)의 전원 단추를 누릅니다. 그러 면 전원 표시등이 켜집니다. 운영 체제 설치 완료 시스템 구입 시 운영 체제가 미리 설치되어 있는 경우 시스템과 함께 제공되 는 운영 체제 설명서를 참조하십시오. 운영 체제를 처음 설치하려면 운영 체 제 설치 및 구성 설명서를 참조하십시오. 시스템과 함께 구입하지 않은 하드 웨어 또는 소프트웨어를 설치하기 전에 운영 체제가 설치되어 있는지 확인 하십시오.
• Microsoft Windows Server 2003 R2 Standard 및 Enterprise (x64) Edition (SP2) • Microsoft Windows Server 2003 R2 Standard 및 Enterprise (x86) Edition (SP2) • Red Hat® Enterprise Linux® ES (버전 5.3)(x86) • • Red Hat Enterprise Linux ES (버전 5.3)(x86_64) SUSE® Linux Enterprise Server 11 (x86_64) • Microsoft Windows Server 2008 Hyper-V™ 주: 지원되는 운영 체제에 대한 최신 정보는 www.dell.com을 참조하십시오. 기타 필요한 정보 경고 : 시스템과 함께 제공되는 안전 및 규제 정보를 참조하십시오 . 보증 정 보는 본 문서에 포함되거나 별도의 문서로 제공될 수 있습니다 .
기술 사양 프로세서 프로세서 유형 쿼드 코어 Intel® Xeon® 프로세서 1개 확장 버스 버스 유형 PCI Express Generation 2 확장 슬롯 슬롯1: PCIe x8 (x8 라우팅) half-length 슬롯2: PCIe x16 (x8 라우팅) full-length 슬롯3: PCIe x8 (x4 라우팅) half-length 슬롯4: PCIe x1 (x1 라우팅) half-length 슬롯5: PCIe x1 (x1 라우팅) half-length 메모리 아키텍처 800 MHz, 1066 MHz 또는 1333 MHz DDR3 Registered 또는 Unbuffered ECC (Error Correcting Code) DIMM 메모리 모듈 소켓 240핀 6개 메모리 모듈 용량 1 GB, 2 GB, 4 GB 또는 8 GB 최소 RAM 1 GB 최대 RAM 32 GB 드라이브 하드 드라이브 3.
드라이브 ( 계속 ) 광학 드라이브 내장형 SATA DVD-ROM 또는 DVD+/-RW (선택 사양) 외장형 USB DVD-ROM (선택 사양) 주: DVD 장치는 데이터 전용입니다. 테이프 드라이브 내장형 half height 테이프 백업 장치 (선택 사양) 1개 커넥터 후면 NIC RJ-45 (내장형 1GB NIC용) 2개 직렬 9핀, DTE, 16550 호환 USB 4핀 4개, USB 2.0 호환 비디오 15핀 VGA 전면 4핀 2개, USB 2.0 호환 USB 내부 4핀 2개, USB 2.0 호환 USB 비디오 비디오 유형 Matrox G200, iDRAC에 통합 비디오 메모리 8 MB 전원 AC 전원 공급 장치(전원 공급 장치마다) 와트 375 W (비중복 전원 공급 장치) 400 W (중복 전원 공급 장치) 전압 100-240 VAC, 50/60 Hz, 5.8 A-2.
전원 ( 계속 ) 최대 유입 전류 일반적인 회선 상태 및 전체 시스템 작동 범 위에서 유입 전류는 10ms 이하 동안 전원 공 급 장치당 25 A (중복 전원 공급 장치) 및 35 A (비중복 전원 공급 장치)까지 도달할 수 있습 니다. 전지 시스템 전지 CR 2032 3.0 V 리튬 이온 코인 셀 규격 높이 44 cm (17.3인치) 너비 21.8 cm (8.6인치) 깊이 52.1 cm (20.5인치) 무게(최대 구성 시) 23.5 kg (51.8 lb) 환경 주: 특정 시스템 구성을 위한 환경 측정에 대한 자세한 정보는 www.dell.com/environmental_datasheets를 참조하십시오. 온도 작동 10°~35°C (50°~95°F), 시간당 최고 10°C의 온도 변화 기준 주: 2,950피트 이상의 고도에서 최대 작동 온 도는 1°F/550 ft로 감소됩니다.
환경 ( 계속 ) 최대 충격 작동 작동 방향으로 2.6 ms 동안 (+) z축으로 31G 의 충격 펄스 1회(시스템 각 면에 1회의 펄스) 보관 최대 2 ms 동안 (+/-) x, y, z축으로 71G의 연속 충격 펄스(시스템 각 면에 1회의 펄스) 6회 고도 작동 0~3,048 m (0~10,000 ft) 주: 2,950피트 이상의 고도에서 최대 작동 온 도는 1°F/550 ft로 감소됩니다. 보관 0~10,605 m (–50~35,000 ft) 공기 중 오염 수준 등급 54 ISA-S71.