Heat dissipation
1650 BTU/hr maximum
(Non-redundant power supply)
1627 BTU/hr maximum
(Redundant power supply)
Maximum inrush current
Under typical line conditions and over the
entire system ambient operating range, the
inrush current may reach 55 A per power
supply for 10 ms or less.
Batteries
System battery
CR 2032 3.0-V lithium ion coin cell
Physical
Height 44.5 cm (17.52 in)
Width 21.8 cm (8.58 in)
Depth 61.7 cm (24.28 in)
Weight (maximum configuration) 28.4 kg (62.61 lb)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet, the
maximum operating temperature is derated
1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation of
20°C per hour
Power (continued)
section.fm Page 11 Tuesday, January 27, 2009 5:15 PM