Reference Guide Dell EMC PowerStore Events and Alerts Reference Guide Abstract This document includes information about the alerts and events messages that can appear or get logged for your Dell EMC PowerStore cluster.
Table of contents The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright © May 2020 Dell Inc. or its subsidiaries. All Rights Reserved.
Table of contents Table of contents Table of contents ................................................................................................................................................................3 1 2 3 Introduction ...................................................................................................................................................................4 1.1 Monitor an alert or event..............................................................................
Introduction 1 Introduction Alerts and events are one of the core serviceability capabilities available in PowerStore. The system generates several alerts and events based on the health of the cluster or user actions. They are critical in helping you monitor the health of the cluster, troubleshoot issues with your cluster, and triage and fix issues that require attention. An event indicates that something of interest happened in the system.
Alert and Event Messages - • • • • • 1.3 Info – An event that does not impact the cluster performance or functions. No action is required. Alert Raised – Indicates whether the event also resulted in an alert that got generated. Call Home – Indicates whether the event resulted in a notification to the Dell EMC Support Center. Repair Flow – If applicable, steps or recommendations to fix the issue. System Impact – If applicable, additional information on the impact of the event on the cluster.
Alert and Event Messages Event code Severity Alert raised Call home Message Drive data equalization began on %(node_name). Drive data equalization finished on %(node_name). Drive rebuild began on %(node_name). Drive rebuild finished on %(node_name). Repair flow System impact Knowledge Base Article 0x00200101 INFO FALSE FALSE - - - 0x00200102 INFO FALSE FALSE - - - 0x00200201 INFO TRUE TRUE No action required. Cluster performance may be impacted.
Alert and Event Messages Event code Severity Alert raised Call home 0x00200A02 INFO FALSE FALSE 0x00200B01 CRITICAL TRUE FALSE 0x00200B02 INFO FALSE FALSE 0x00200C01 CRITICAL TRUE FALSE 0x00200C02 INFO FALSE FALSE 0x00200D01 CRITICAL TRUE FALSE 0x00200D02 INFO FALSE FALSE Message Log metadata tier page descriptor uncorrectable error is fixed. Log metadata tier metadata page descriptor uncorrectable error at pageIndex = %(page_index), length = %(length).
Alert and Event Messages Event code Severity Alert raised Call home Message 0x00200E06 MAJOR TRUE FALSE Capacity utilization is above 97 percent. 0x00200E07 MAJOR TRUE FALSE Capacity utilization is above 98 percent. 0x00200E08 MAJOR TRUE FALSE Capacity utilization is above 99 percent.
Alert and Event Messages Event code Severity Alert raised Call home Message Repair flow 0x00201201 INFO TRUE TRUE Cache is degraded. No action required. 0x00201202 INFO FALSE FALSE Cache is online. - 0x00201301 CRITICAL TRUE TRUE Appliance enters read only due to corruption of critical metadata. Bring the appliance down and run the recovery script. 0x00201302 INFO FALSE FALSE Critical metadata is recovered, appliance exits read only.
Alert and Event Messages Event code Severity Alert raised Call home Message Cluster state was changed from %(old_value) to %(sys_state). Cluster state was changed from %(old_value) to %(sys_state). Cluster state was changed from %(old_value) to %(sys_state). The cluster service is stopping. Stop reason is: %(stopped_reason). The cluster service has stopped. Stopped type is: %(sys_stop_type), stopped reason is: %(stopped_reason). The cluster is in the process of starting.
Alert and Event Messages Event code Severity Alert raised Call home 0x00300F02 CRITICAL TRUE TRUE 0x00300F03 CRITICAL TRUE TRUE 0x00300F04 CRITICAL TRUE TRUE 0x00300F06 CRITICAL TRUE TRUE 0x00300F07 CRITICAL TRUE TRUE 0x00300F08 CRITICAL TRUE TRUE 0x00300F09 CRITICAL TRUE TRUE 0x00300F0B CRITICAL TRUE TRUE 0x00300F0C CRITICAL TRUE TRUE 0x00300F0D CRITICAL TRUE TRUE 0x00301201 MINOR FALSE FALSE 0x00301202 MAJOR TRUE TRUE 0x00301301 INFO FALSE FALSE 0x00
Alert and Event Messages Event code Severity Alert raised Call home 0x00301503 MINOR FALSE FALSE 0x00301504 MINOR FALSE FALSE 0x00301505 MAJOR TRUE TRUE 0x00301506 MAJOR TRUE TRUE 0x00301507 MINOR FALSE FALSE 0x00301508 MINOR FALSE FALSE 0x00301601 INFO FALSE FALSE 0x00301602 MAJOR TRUE FALSE 0x00301603 INFO FALSE FALSE 0x00301604 INFO FALSE FALSE 12 Message Encryption is supported on this drive and the drive has been locked.
Alert and Event Messages Event code Severity Alert raised Call home 0x00301701 MINOR FALSE FALSE 0x00301702 INFO FALSE FALSE 0x00301703 INFO FALSE FALSE 0x00301704 MAJOR TRUE FALSE 0x00301C01 MINOR TRUE TRUE 0x00301C02 NONE FALSE FALSE 0x00301D01 NONE FALSE FALSE Message %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(tcg_compliance). The drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(fips_status).
Alert and Event Messages Event code Severity Alert raised Call home 0x00301F02 MAJOR TRUE TRUE 0x00302001 MINOR FALSE FALSE 0x00302002 MINOR FALSE FALSE 0x00302006 MAJOR TRUE TRUE 0x00302901 NONE FALSE FALSE 0x00302902 MINOR FALSE FALSE 0x00302903 MINOR FALSE FALSE 0x00302904 MINOR FALSE FALSE 0x00302B01 NONE FALSE FALSE 0x00302B02 MAJOR FALSE FALSE 0x00302B03 MAJOR FALSE FALSE 0x00302B04 MAJOR FALSE FALSE 0x00302B07 MAJOR FALSE FALSE 0x00302B08 MAJOR
Alert and Event Messages Event code Severity Alert raised Call home 0x00302B0A MAJOR FALSE FALSE 0x00302E01 NONE FALSE FALSE Message The Node is not configured as part of the cluster. Node is waiting for activation. SAS port 1 rate changed from %(old_value) to %(sas1_port_rate) Repair flow System impact Knowledge Base Article - - https://www.dell.com/support /Article/SLN317238 - - - - https://www.dell.
Alert and Event Messages Event code Severity Alert raised Call home 0x00304401 NONE FALSE FALSE 0x00304402 NONE FALSE FALSE Message The node lifecycle state has changed from %(old_value) to %(fru_lifecycle_state). Node is initializing. 0x00304403 CRITICAL TRUE TRUE Node has faulted. 0x00304404 MAJOR TRUE FALSE Node has been physically removed or shut down.
Alert and Event Messages Event code Severity Alert raised Call home Message 0x00305303 MAJOR TRUE TRUE Interconnect port 1 has failed. 0x00305402 MAJOR TRUE TRUE Interconnect port 2 is degraded. 0x00305403 MAJOR TRUE TRUE Interconnect port 2 has failed.
Alert and Event Messages Event code Severity Alert raised Call home 0x00305606 MAJOR TRUE TRUE 0x00305701 MINOR FALSE FALSE 0x00305702 MAJOR FALSE TRUE 0x00305703 MAJOR FALSE TRUE 0x00305801 MINOR FALSE FALSE 0x00305802 MINOR FALSE FALSE Message Internal M.2 boot module in slot %(slot_num) is not initialized. The enabled state for the internal M.2 boot module has changed from %(old_value) to %(enabled_state). The InternalM.2BootModule was deactivated (disabled) by user request.
Alert and Event Messages Event code Severity Alert raised Call home 0x00305904 NONE FALSE FALSE 0x00305905 MAJOR FALSE FALSE 0x00305906 MAJOR FALSE FALSE 0x00305A01 NONE FALSE FALSE 0x00305A02 NONE FALSE FALSE 0x00305A03 NONE FALSE FALSE 0x00305B01 NONE FALSE FALSE 0x00305B02 MINOR FALSE FALSE 0x00305B03 0x00305B04 MAJOR MAJOR TRUE TRUE TRUE Node's power supply unit has faulted. FALSE Node's power supply unit is disconnected.
Alert and Event Messages Event code Severity Alert raised Call home Message 0x00305B08 INFO FALSE FALSE Node's power supply unit has been replaced. Appliance's %(location) power supply unit has no input power.
Alert and Event Messages Event code Severity Alert raised Call home 0x00306C04 CRITICAL TRUE TRUE 0x00306D01 0x00306D02 0x00306D03 0x00306D04 0x00306D05 MINOR MINOR MINOR MINOR MAJOR FALSE TRUE TRUE TRUE TRUE Message Drive endurance level for bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is exhausted. The remaining wear level for this drive is %(percent_endurance_rem aining)%. System impact Knowledge Base Article Contact your service provider.
Alert and Event Messages Event code 0x00306E02 0x00306E03 0x00306E04 0x00306E05 0x00306E06 Severity MINOR MINOR MINOR MAJOR MAJOR Alert raised TRUE TRUE TRUE TRUE TRUE Call home Repair flow TRUE Link 1 state of drive in %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) cannot be determined. The drive state is unknown. - TRUE Cluster diagnostics detected a minor problem in link 1 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot).
Alert and Event Messages Event code Severity Alert raised Call home 0x00306F03 MINOR TRUE TRUE 0x00306F04 MINOR TRUE TRUE 0x00306F05 MAJOR TRUE TRUE 0x00306F06 MAJOR TRUE TRUE 0x00307001 MINOR FALSE FALSE 0x00307002 MAJOR TRUE TRUE 0x00307003 MAJOR TRUE TRUE 0x00307101 INFO FALSE FALSE 23 Message %(encl_num) slot %(enclosure_slot) cannot be determined. The drive state is unknown.
Alert and Event Messages Event code Severity Alert raised Call home 0x00307102 INFO FALSE FALSE 0x00307103 CRITICAL TRUE TRUE 0x00307104 MAJOR TRUE FALSE 0x00307105 MINOR TRUE FALSE 0x00307106 MINOR TRUE TRUE 0x00307107 MINOR FALSE FALSE 0x00307108 MINOR TRUE FALSE 0x00307201 INFO FALSE FALSE 0x00307202 INFO FALSE FALSE 0x00307203 MAJOR TRUE TRUE 24 Message changed from %(old_value) to %(fru_lifecycle_state).
Alert and Event Messages Event code 0x00307204 MINOR TRUE TRUE 0x00307301 INFO FALSE FALSE 0x00307302 MAJOR TRUE TRUE 0x00307303 MAJOR TRUE TRUE 0x00307304 MAJOR TRUE TRUE 0x00307401 INFO FALSE FALSE 0x00307402 INFO FALSE FALSE 0x00307403 INFO FALSE FALSE Message enclosure %(encl_num) slot %(enclosure_slot) is incompatible. Firmware version of the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is incorrect.
Alert and Event Messages Event code Severity Alert raised Call home Message Repair flow System impact 0x00307705 MAJOR TRUE TRUE XEnv is failed. - - 0x00307706 MAJOR FALSE FALSE XENV state has changed from %(old_value) to %(xenv_state). - Node may not serve IOs. https://www.dell.com/support /Article/SLN317200 0x00307707 MAJOR TRUE TRUE Internal sub-process (xenv) state is performing fail-over. - Internal sub-process is in the process of fail-over into the other Node.
Alert and Event Messages Event code Severity Alert raised Call home 0x00307D05 MAJOR TRUE TRUE 0x00307D06 MAJOR TRUE TRUE 0x00307E01 INFO FALSE FALSE 0x00307E02 MINOR TRUE TRUE 0x00307E04 MINOR TRUE TRUE 0x00307E05 MAJOR TRUE TRUE 0x00307E06 MAJOR TRUE TRUE 0x00307F01 INFO FALSE FALSE 0x00307F02 MAJOR TRUE TRUE 27 Message healthy and has been disabled. Bus %(bus_num) Enclosure %(encl_num) %(identification) SAS1 port health level is problematic. Attention is required.
Alert and Event Messages Event code Severity Alert raised Call home 0x00307F03 MINOR FALSE FALSE 0x00308001 INFO FALSE FALSE 0x00308002 MINOR TRUE TRUE 0x00308003 MINOR FALSE FALSE 0x00308101 INFO FALSE FALSE 0x00308102 MAJOR TRUE TRUE 0x00308103 MAJOR TRUE TRUE 0x00308201 INFO FALSE FALSE 0x00308202 MINOR FALSE FALSE 28 Message %(identification) port A is down.
Alert and Event Messages Event code Severity Alert raised Call home 0x00308203 MAJOR TRUE TRUE 0x00308204 MAJOR TRUE TRUE 0x00308205 MINOR TRUE TRUE 0x00308206 MINOR TRUE TRUE 0x00308207 INFO TRUE FALSE 0x00308301 INFO FALSE FALSE 0x00308302 INFO TRUE TRUE 0x00308303 MAJOR TRUE TRUE Message Bus %(bus_num) enclosure %(encl_num) %(identification) has failed. Bus %(bus_num) enclosure %(encl_num) %(identification) is disconnected.
Alert and Event Messages Event code Severity Alert raised Call home 0x0030840C MINOR TRUE TRUE 0x0030840D MINOR TRUE TRUE 0x0030840E MINOR TRUE TRUE 0x0030840F MAJOR TRUE TRUE 0x00308410 MAJOR TRUE TRUE 0x00308501 INFO FALSE FALSE 0x00308502 MINOR TRUE TRUE 0x00308503 MINOR TRUE TRUE 30 Message state was changed from %(old_value) to %(lcc_health_level). Bus %(bus_num) Enclosure %(encl_num) %(identification) health information is unavailable.
Alert and Event Messages Event code Severity Alert raised Call home 0x00308504 MINOR TRUE TRUE 0x00308505 MAJOR TRUE TRUE 0x00308506 MAJOR TRUE TRUE 0x00308601 MAJOR TRUE TRUE 0x00308602 INFO FALSE FALSE 0x00308701 INFO FALSE FALSE 0x00308702 MAJOR TRUE TRUE 0x00308703 MAJOR TRUE TRUE 0x00308704 MAJOR TRUE TRUE 31 Message Bus %(bus_num) Enclosure %(encl_num) %(identification) PHY %(phy_ports[].phy_index) health status is limited.
Alert and Event Messages Event code Severity Alert raised Call home 0x00308801 INFO FALSE FALSE 0x00308802 MAJOR TRUE Message State of the Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU was changed from %(old_value) to %(enabled_state). The Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU was manually disabled by user request. The cluster has disabled the Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU.
Alert and Event Messages Event code Severity Alert raised Call home 0x00308907 INFO TRUE FALSE 0x00308A01 INFO FALSE FALSE 0x00308A02 INFO TRUE TRUE 0x00308A03 0x00308A04 MAJOR MINOR TRUE TRUE TRUE TRUE 0x00308B01 INFO FALSE FALSE 0x00308B02 MINOR FALSE FALSE 0x00308B03 33 MAJOR TRUE TRUE Message The Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU has been replaced.
Alert and Event Messages Event code 0x00308B04 Severity MAJOR Alert raised TRUE Call home Message TRUE Expansion enclosure %(encl_num) at bus %(bus_num) is disconnected.
Alert and Event Messages Event code Severity Alert raised Call home 0x00308F02 NONE FALSE FALSE Message changed from %(old_value) to %(fru_lifecycle_state). Battery backup module is initializing. 0x00308F03 MAJOR TRUE TRUE Battery backup module has faulted. 0x00308F04 MAJOR TRUE FALSE Battery backup module is disconnected.
Alert and Event Messages Event code Severity Alert raised Call home 0x00309004 MINOR FALSE FALSE 0x00309005 MINOR FALSE FALSE 0x00309006 MINOR FALSE FALSE 0x00309007 MINOR FALSE FALSE 0x00309008 MINOR FALSE FALSE 0x00309101 NONE FALSE FALSE 0x00309102 NONE FALSE FALSE 0x00309103 MAJOR TRUE TRUE 36 Message Firmware upgrade state of Bus %(bus_num) Enclosure %(encl_num) %(identification) was changed from %(old_value) to %(fw_upgrade_state).
Alert and Event Messages Event code Severity Alert raised Call home 0x00309201 NONE FALSE FALSE 0x00309202 NONE FALSE FALSE Message Lifecycle state of the component in %(iom_index) has changed from %(old_value) to %(fru_lifecycle_state). Lifecycle state of the component in %(iom_index) has changed from %(old_value) to %(fru_lifecycle_state). 0x00309203 MAJOR TRUE TRUE Node's IOM has failed. 0x00309204 MINOR TRUE FALSE Node's IOM %(iom_index) is disconnected from the cluster.
Alert and Event Messages Event code Severity Alert raised Call home 0x00309303 NONE FALSE FALSE 0x00309401 NONE FALSE FALSE 0x00309402 NONE FALSE FALSE Message changed from %(old_value) to %(enabled_state). The cluster has disabled the Node's Fan Module. Lifecycle state of the node's fan module has changed from %(old_value) to %(fru_lifecycle_state). Node's fan module is initializing. 0x00309403 MAJOR TRUE TRUE Node's fan module has faulted.
Alert and Event Messages Event code Severity Alert raised Call home 0x00309508 INFO FALSE FALSE 0x00309601 NONE FALSE FALSE 0x00309602 NONE FALSE FALSE 0x00309603 NONE FALSE FALSE 0x00309701 MINOR FALSE FALSE 0x00309702 MINOR FALSE FALSE 0x00309703 MAJOR TRUE TRUE 0x00309704 MINOR TRUE FALSE 0x00309705 MINOR FALSE FALSE 0x00309706 INFO FALSE FALSE 0x00309801 MAJOR FALSE TRUE 0x00309802 MINOR FALSE FALSE 0x00309803 MAJOR FALSE TRUE 0x00309901 NONE FAL
Alert and Event Messages Event code Severity Alert raised Call home 0x0030A001 MINOR FALSE FALSE 0x0030A002 0x0030A003 0x0030A004 0x0030A005 0x0030A006 MINOR MINOR MINOR MINOR MINOR FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE 0x0030A101 INFO FALSE FALSE 0x0030A102 MINOR FALSE FALSE 0x0030A103 MINOR TRUE FALSE Message Repair flow initiator is disconnected and then reconnected.
Alert and Event Messages Event code Severity Alert raised Call home Message 0x0030A204 MAJOR TRUE FALSE Component part number %(part_number) does not match with the expected part number %(expected_part_number) for this slot. 0x0030A205 MAJOR TRUE FALSE Component serial number is not readable by the software. 0x0030A206 MINOR TRUE FALSE An unexpected component was found. InternalBatteryBackupModu le's energy required setting is not set at expected value.
Alert and Event Messages Event code Severity Alert raised Call home 0x0030A409 NONE FALSE FALSE 0x0030A40A NONE FALSE FALSE 0x0030A40B NONE FALSE FALSE 0x0030A40C NONE FALSE FALSE 0x0030A40D NONE FALSE FALSE 0x0030A40E NONE FALSE FALSE 0x0030A40F NONE FALSE FALSE 0x0030A410 NONE FALSE FALSE 0x0030A411 NONE FALSE FALSE 0x0030A412 NONE FALSE FALSE 0x0030A601 INFO FALSE FALSE 0x0030A602 MAJOR TRUE FALSE 0x0030A603 MAJOR TRUE FALSE 0x0030A701 INFO FALSE
Alert and Event Messages Event code Severity Alert raised Call home 0x0030A702 INFO FALSE FALSE 0x0030A703 MINOR TRUE FALSE 0x0030A704 MAJOR TRUE FALSE 0x0030A705 MAJOR TRUE FALSE 0x0030A706 MAJOR TRUE FALSE 0x0030A707 MAJOR TRUE FALSE 0x0030A801 INFO FALSE FALSE 0x0030A802 INFO FALSE FALSE 43 Message from %(old_value) to %(sas1_cable_status). SAS Connector A on Bus %(bus_num) Enclosure %(encl_num) %(identification) is %(sas1_connt_status).
Alert and Event Messages Event code Severity Alert raised Call home 0x0030A803 MINOR TRUE FALSE 0x0030A804 MINOR TRUE FALSE 0x0030A805 INFO TRUE FALSE 0x0030A806 INFO TRUE FALSE 0x0030A807 MAJOR TRUE FALSE 0x0030A901 NONE FALSE FALSE 0x0030A902 MAJOR TRUE FALSE 0x0030AA01 NONE FALSE FALSE 0x0030AA02 NONE FALSE FALSE 0x0030AA03 MINOR TRUE FALSE Message from %(old_value) to %(sas2_cable_status).
Alert and Event Messages Event code 0x0030AB02 0x0030AB03 0x0030AB04 Severity MINOR INFO MAJOR Alert raised TRUE TRUE TRUE Call home FALSE Message from %(old_value) to %(fru_comp_status). Node's %(location) power supply unit with part number %(part_number) is not supported in this configuration. FALSE Node's %(location) power supply does not match its peer node.
Alert and Event Messages Event code Severity Alert raised Call home 0x0030AD01 MINOR TRUE TRUE 0x0030AD02 NONE FALSE FALSE 0x0030AE01 MAJOR TRUE TRUE 0x0030AE02 NONE FALSE FALSE 0x0030AF01 INFO FALSE FALSE 0x0030AF02 MAJOR TRUE TRUE 0x0030AF03 MAJOR TRUE TRUE 0x0030AF04 MAJOR TRUE TRUE 0x0030AF05 MAJOR TRUE TRUE 46 Message Bus %(bus_num) enclosure %(encl_num) has exceeded the temperature warning threshold.
Alert and Event Messages Event code 0x0030AF06 Severity MAJOR Alert raised TRUE Call home TRUE Message Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because one or more required hardware components are not installed. Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down for an unspecified reason.
Alert and Event Messages Event code Severity Alert raised Call home 0x0030B105 NONE FALSE FALSE 0x0030B106 NONE FALSE FALSE 0x0030B107 NONE FALSE FALSE 0x0030B108 NONE FALSE FALSE 0x0030B201 NONE FALSE FALSE 0x0030B202 NONE FALSE FALSE 0x0030B203 NONE FALSE FALSE 0x0030B204 NONE FALSE FALSE 0x0030B301 NONE FALSE FALSE 0x0030B302 NONE FALSE FALSE 0x0030B303 NONE FALSE FALSE 0x0030B304 NONE FALSE FALSE 0x0030B401 INFO FALSE FALSE 0x0030B402 INFO FALSE
Alert and Event Messages Event code Severity Alert raised Call home 0x0030B509 NONE FALSE FALSE 0x0030B50A NONE FALSE FALSE 0x0030B50B NONE FALSE FALSE 0x0030B601 NONE FALSE FALSE Message Clustering agent required action has changed. Clustering agent required action has changed. Clustering agent required action has changed. Compatibility status of the Node DIMM%(dimm_index) was changed from %(old_value) to %(fru_comp_status).
Alert and Event Messages Event code Severity Alert raised Call home 0x0030BA01 NONE FALSE FALSE Message Polling status of the internal M.2 boot module in slot %(slot_num) has changed from %(old_value) to %(local_disk_polling_status ). 0x0030BA02 MAJOR TRUE TRUE Polling failed for internal M.2 boot module in slot %(slot_num). 0x0030BA03 CRITICAL TRUE TRUE Root file system is readonly on internal M.2 boot module in slot %(slot_num).
Alert and Event Messages Event code Severity Alert raised Call home 0x0030C202 NONE FALSE FALSE 0x0030C203 NONE TRUE FALSE Message expected values of %(wwn_seed_string), %(dell_service_tag), %(product_serial_number) respectively. Drive on bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is running at partial rate Drive on bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is running at partial rate Information could not be updated for any of the DIMMs for this node.
Alert and Event Messages Event code Severity Alert raised Call home 0x00400101 INFO FALSE FALSE 0x00400102 INFO FALSE FALSE 0x00400103 INFO FALSE FALSE 0x00400104 INFO FALSE FALSE 0x00400105 INFO FALSE FALSE 0x00400106 INFO FALSE FALSE 0x00400107 CRITICAL TRUE TRUE 0x00400108 INFO FALSE FALSE 0x00400201 INFO FALSE FALSE 0x00400202 INFO FALSE FALSE 0x00400301 INFO FALSE FALSE 0x00400302 CRITICAL TRUE TRUE 0x00400303 MAJOR TRUE FALSE 0x00400304 INFO FA
Alert and Event Messages Event code Severity Alert raised Call home 0x00500201 NONE FALSE FALSE 0x00500202 NONE FALSE FALSE 0x00500203 NONE FALSE FALSE 0x00500301 CRITICAL TRUE FALSE 0x00500302 NONE FALSE FALSE 0x00600101 INFO FALSE FALSE 0x00600201 INFO FALSE FALSE 0x00600301 INFO FALSE FALSE 0x00600401 INFO TRUE FALSE 0x00600402 INFO FALSE FALSE 0x00700101 INFO FALSE FALSE 0x00700102 INFO FALSE FALSE 0x00700103 MAJOR FALSE FALSE 0x00700104 MAJOR FA
Alert and Event Messages Event code Severity Alert raised Call home Repair flow System impact Knowledge Base Article - - https://www.dell.
Alert and Event Messages Event code 0x00900D04 Severity INFO Alert raised FALSE Call home FALSE 0x00901001 MAJOR TRUE FALSE 0x00901002 INFO FALSE FALSE 0x00901003 INFO FALSE FALSE 0x00901301 0x00901302 55 MINOR INFO TRUE FALSE FALSE FALSE Message specified in the %(replication_rule_name) rule. Protection configuration for %(source_name) has been updated.
Alert and Event Messages Event code 0x00901303 0x00901304 Severity MAJOR INFO Alert raised TRUE FALSE Call home FALSE FALSE 0x00906501 MAJOR TRUE FALSE 0x00906502 INFO FALSE FALSE 0x00906503 INFO FALSE FALSE 0x00906701 MAJOR TRUE FALSE 0x00906702 INFO FALSE FALSE 0x00906B01 INFO FALSE FALSE 0x00906B02 MINOR TRUE FALSE 56 Message %(replication_rule_name) rule.
Alert and Event Messages Event code Severity Alert raised Call home 0x00906B03 MAJOR TRUE FALSE 0x00906B04 MAJOR TRUE FALSE 0x00906B05 MAJOR TRUE FALSE 0x00906B06 MAJOR TRUE FALSE 0x00906B07 MAJOR TRUE FALSE 0x00906B08 INFO FALSE FALSE 0x00906B09 57 MINOR TRUE FALSE Message using the %(rule_name) rule by schedule. Skipped creation of scheduled snapshot from virtual machine %(source_name) because a drive was detected of a type that is not a virtual volume.
Alert and Event Messages Event code 0x00906B0A Severity MINOR Alert raised TRUE Call home Message FALSE Created a non-quiesced snapshot from virtual machine %(source_name) using the %(rule_name) rule by schedule after removing the closest expiring vm snapshots.
Alert and Event Messages Event code Severity Alert raised Call home 0x00906E03 INFO FALSE FALSE 0x00906F01 MAJOR TRUE FALSE 0x00906F02 INFO FALSE FALSE 0x00907001 MAJOR TRUE FALSE 0x00907002 INFO FALSE FALSE 0x00A00101 MAJOR TRUE FALSE 0x00A00102 INFO FALSE FALSE 0x00A00201 INFO FALSE FALSE 0x00A00202 INFO FALSE FALSE 59 Message Protection configuration for %(source_name) has been updated.
Alert and Event Messages Event code Severity Alert raised Call home 0x00A00301 MAJOR TRUE FALSE 0x00A00302 MINOR TRUE FALSE 0x00A00303 INFO FALSE FALSE 0x00A00401 MAJOR TRUE FALSE 0x00A00402 MINOR TRUE FALSE 0x00A00403 INFO FALSE FALSE 0x00A00501 INFO FALSE FALSE 0x00A00502 MAJOR TRUE FALSE 0x00B00201 INFO FALSE FALSE 0x00B00301 INFO FALSE FALSE 0x00B00302 INFO FALSE FALSE 0x00B00303 INFO FALSE FALSE 0x00B00401 INFO FALSE FALSE 0x00B00402 INFO FALSE
Alert and Event Messages Event code Severity Alert raised Call home 0x00B00601 NONE FALSE FALSE 0x00B00602 MINOR TRUE FALSE 0x00B00603 MAJOR TRUE TRUE 0x00B00701 NONE FALSE FALSE 0x00B00702 CRITICAL TRUE TRUE 0x00B00703 CRITICAL TRUE TRUE 0x00B00704 CRITICAL TRUE TRUE Message The appliance %(appl_id) is eligible to assume cluster responsibilities. The appliance %(appl_id) is temporarily suspended from participating in HA.
Alert and Event Messages Event code 0x00D00201 Severity MAJOR Alert raised TRUE Call home TRUE Cluster connectivity to SupportAssist is degraded. Appliance status: %(appliance_info). One or more appliances are not connected to the SupportAssist or SRS Gateway. Appliance status: %(appliance_info).
Alert and Event Messages Event code 0x00E00102 Severity NONE Alert raised FALSE Call home FALSE 0x00E00103 NONE FALSE FALSE 0x00E00104 NONE FALSE FALSE 0x00E00105 0x00E00106 0x00E00107 0x00E00108 NONE NONE NONE NONE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE 0x00E00109 MAJOR TRUE FALSE 0x00E0010A NONE FALSE FALSE 0x00E0010B MAJOR TRUE FALSE 0x00E0010C NONE FALSE FALSE 0x00E0010D NONE FALSE FALSE 0x00E0010E NONE FALSE FALSE 0x00E0010F NONE FALSE FALSE 0x00E001
Alert and Event Messages Event code Severity Alert raised Call home 0x00F00107 CRITICAL TRUE TRUE 0x00F00108 MINOR TRUE FALSE 0x00F0010A INFO FALSE FALSE 0x00F0010B INFO FALSE FALSE 0x00F0010C MINOR TRUE FALSE 0x00F0010D INFO FALSE FALSE 0x00F0010E INFO FALSE FALSE 0x00F0010F INFO FALSE FALSE 0x00F00110 64 CRITICAL TRUE TRUE Message Volume Group %(import_session_name) cutover completed with errors.
Alert and Event Messages Event code Severity Alert raised Call home 0x00F00112 INFO FALSE FALSE 0x00F00113 MINOR TRUE FALSE 0x00F00115 INFO FALSE FALSE 0x00F00116 MINOR TRUE FALSE 0x00F00118 INFO FALSE FALSE 0x00F00119 INFO FALSE FALSE 0x00F0011A INFO FALSE FALSE 0x00F0011B 0x00F0011C 65 CRITICAL CRITICAL TRUE TRUE TRUE TRUE Message Import session %(import_session_name) has successfully paused. Pause for import session %(import_session_name) has failed.
Alert and Event Messages Event code 0x00F0011D 0x00F0011E 0x00F0011F 0x00F00120 Severity MINOR MINOR MINOR CRITICAL Alert raised TRUE TRUE TRUE TRUE Call home Message FALSE Operation on import session %(import_session_name) has failed with errors on the source side. FALSE Operation on import session %(import_session_name) has failed with errors on the host side. FALSE Operation on import session %(import_session_name) has failed with errors on the destination side.
Alert and Event Messages Event code Severity Alert raised Call home 0x00F00126 MINOR TRUE FALSE 0x00F00127 CRITICAL TRUE TRUE 0x00F00128 MINOR TRUE FALSE 0x00F00129 MINOR TRUE FALSE 0x00F0012A MINOR TRUE FALSE 0x00F0012B MINOR TRUE FALSE 0x00F0012C MINOR TRUE FALSE 0x00F0012D MINOR TRUE FALSE 0x00F00201 MAJOR TRUE FALSE 0x00F00202 INFO FALSE FALSE 0x00F00203 INFO TRUE FALSE 67 Message %(import_session_name) has failed.
Alert and Event Messages Event code Severity Alert raised Call home 0x00F00204 INFO FALSE FALSE 0x00F00205 MAJOR TRUE FALSE 0x00F00207 INFO FALSE FALSE 0x00F00208 INFO TRUE FALSE 0x00F00209 INFO FALSE FALSE 0x00F0020A CRITICAL TRUE TRUE 0x00F00301 INFO FALSE FALSE 0x00F00302 INFO FALSE FALSE Message The host system %(mgmt_address) has been removed successfully. The host system %(mgmt_address) is in a degraded state. Host system %(mgmt_address) is in the normal state.
Alert and Event Messages Event code Severity Alert raised Call home 0x00F00309 INFO FALSE FALSE 0x00F0030A INFO TRUE FALSE 0x00F0030B INFO FALSE FALSE 0x00F00401 MINOR TRUE FALSE 0x00F00402 INFO FALSE FALSE 0x00F00403 INFO FALSE FALSE 0x01000101 INFO FALSE FALSE 0x01000201 INFO FALSE FALSE 0x01100101 INFO FALSE FALSE 0x01100201 INFO FALSE FALSE 0x01100202 MAJOR TRUE FALSE 69 Message discovery or refresh has failed.
Alert and Event Messages Event code Severity Alert raised Call home 0x01100203 INFO FALSE FALSE 0x01100204 INFO FALSE FALSE 0x01300101 NONE FALSE FALSE 0x01300102 0x01300103 0x01300201 0x01300202 70 MINOR MAJOR MAJOR NONE FALSE TRUE TRUE FALSE Message logs for details about the failure. One or more of the migration jobs of the migration recommendation %(id) is now paused. Resume the jobs before execution of the recommendation can be completed.
Alert and Event Messages Event code 0x01300301 Severity MAJOR Alert raised TRUE Call home Message Repair flow FALSE The SMB server of the NAS server %(nasServer) is configured to be joined to the domain %(domain), but is currently not joined. Join the SMB server with join rest api call. This may also be due to a bad DNS configuration. - 0x01300302 NONE FALSE FALSE The SMB server of the NAS server %(nasServer) is now joined to the domain %(domain).
Alert and Event Messages Event code Severity Alert raised Call home 0x01300503 NONE FALSE FALSE 0x01300504 0x01300505 0x01300601 0x01300602 72 MINOR MAJOR MINOR MAJOR FALSE TRUE FALSE FALSE FALSE Message The LDAP client of the NAS server %(nasServer) for domain %(domain) is working properly. The LDAP client of the NAS server %(nasServer) is unable to connect to some of the configured LDAP servers. FALSE No LDAP servers configured for NAS server %(nasServer) are responding.
Alert and Event Messages Event code 0x01300603 Severity MAJOR Alert raised FALSE Call home Message FALSE Total space usage for file system %(fs), quota tree %(treePath) has reached the hard quota limit. Users can no longer write to the quota tree unless this issue is addressed. Total space usage for file system %(fs), quota tree %(treePath) has exceeded the preferred (soft quota) 0x01300604 MINOR FALSE FALSE limit %(softViolations) times.
Alert and Event Messages Event code 0x01300607 0x01300701 0x01300702 0x01300703 74 Severity NONE MINOR MAJOR MAJOR Alert raised FALSE FALSE FALSE FALSE Call home FALSE Message usage no longer exceeds soft quota limit (fs %(mountPoint), quota tree %(treePath) , ID:%(quotaId)). Administrator increased disk space. Quota tree block usage no longer exceeds soft quota limit (fs %(mountPoint), quota tree ID:%(treeQuotaId), ID:%(quotaId)).
Alert and Event Messages Event code 0x01300704 0x01300705 0x01300706 Severity MINOR MAJOR MAJOR Alert raised FALSE FALSE FALSE Call home Message FALSE Space usage by user %(userName) in file system %(fs), quota tree %(treePath) has exceeded the preferred (soft quota) limit. FALSE Space usage by user %(userName) in file system %(fs), quota tree %(treePath) has exceeded the preferred (soft quota) limit, and the grace period has expired.
Alert and Event Messages Event code 0x01300709 Severity MINOR Alert raised FALSE Call home FALSE Message (soft quota) limit, grace period, and hard quota limit. Soft quota limit exceeded %(softViolations) times, grace period expired %(softGraceExpiredViolatio ns) times, hard quota limits reached %(hardViolations) times. First violation %(firstViolation), most recent violation %(lastViolation).
Alert and Event Messages Event code Severity Alert raised Call home 0x01300801 MINOR TRUE FALSE 0x01300802 NONE FALSE FALSE 0x01300901 NONE FALSE FALSE 0x01300902 0x01300903 MAJOR MAJOR TRUE TRUE FALSE FALSE 0x01300904 MAJOR FALSE FALSE 0x01300905 MAJOR FALSE FALSE 0x01300906 CRITICAL TRUE TRUE 0x01300A01 MINOR FALSE FALSE 0x01300A02 NONE FALSE FALSE 77 Message quota no longer exceeded for %(userName) (fs %(mountPoint), %(quotaId)).
Alert and Event Messages Event code Severity Alert raised Call home Message Repair flow 0x01300B01 MINOR FALSE FALSE The virus checker is running normally. No action is required. 0x01300B02 MAJOR TRUE FALSE No virus checker server is available. Make sure the virus checker servers are online. 0x01300B03 MAJOR FALSE FALSE One or more virus checker servers are currently unavailable. - FALSE NAS server %(vdmname) is down.
Alert and Event Messages Event code Severity Alert raised Call home 0x01300F01 NONE FALSE FALSE Repair flow System impact Knowledge Base Article - The snap is operating normally. - Contact your service provider. The snap has received an I/O error and is unmounted. There may be a problem with the storage device. https://www.dell.com/support /Article/SLN317204 Contact your service provider. The snap has discovered internal corruption and is unmounted. https://www.dell.
Alert and Event Messages Event code Severity Alert raised Call home 0x01301201 NONE FALSE FALSE 0x01301202 MAJOR TRUE FALSE 0x01301203 MAJOR TRUE FALSE 0x01301204 MAJOR FALSE FALSE 0x01301205 MAJOR FALSE FALSE 0x01301206 CRITICAL TRUE TRUE 0x01301301 MINOR FALSE FALSE 0x01301302 NONE FALSE FALSE 0x01301401 MINOR FALSE FALSE 0x01301402 NONE FALSE FALSE 0x01301501 MINOR FALSE FALSE 80 Message The %(fsname) file system in NAS server %(vdmname) (fsid %(fsid)) is
Alert and Event Messages Event code 0x01301502 0x01301601 0x01301602 Severity NONE MINOR NONE Alert raised FALSE FALSE FALSE Call home Repair flow FALSE The root file system in NAS node %(node) (fsid %(fsid)) has no suspected impacts from its storage device. - FALSE The root file system in the NAS cluster object (fsid %(fsid)) is low on free space. Contact your service provider.
Alert and Event Messages Event code Severity Alert raised Call home 0x01302101 NONE FALSE FALSE 0x01302201 NONE FALSE FALSE 0x01302301 NONE FALSE FALSE 0x01400301 CRITICAL TRUE TRUE 0x01400302 NONE FALSE FALSE 0x01400303 MINOR TRUE FALSE 0x01500101 INFO TRUE FALSE 0x01500102 INFO FALSE FALSE 0x01500201 CRITICAL TRUE FALSE 0x01500202 MAJOR TRUE FALSE 0x01500203 MINOR TRUE FALSE 0x01500204 INFO TRUE FALSE 82 Message The VirusChecker service %(id) has been c
Alert and Event Messages Event code Severity Alert raised Call home 0x01500205 INFO FALSE FALSE 0x01500206 INFO FALSE FALSE 0x01500301 MINOR TRUE FALSE 0x01500302 INFO FALSE FALSE 0x01600101 0x01600102 83 MINOR MINOR TRUE TRUE Message The software update package %(ndu_software_package_ name) has been installed. The software update package %(ndu_software_package_ name) has been deleted.
Alert and Event Messages Event code Severity Alert raised Call home 0x01600103 INFO FALSE FALSE 0x01600201 0x01600202 INFO MINOR TRUE TRUE Message License successfully installed. FALSE The trial period will expire on %(trial_expiration_timestam p), after which no new storage provisioning will be allowed. Unlicensed appliance(s): %(appliance_list). FALSE The trial period will expire on %(trial_expiration_timestam p), after which no new storage provisioning will be allowed.
Alert and Event Messages Event code Severity Alert raised Call home 0x01600204 INFO FALSE FALSE 0x01700201 NONE FALSE FALSE 0x01700202 MINOR TRUE FALSE 0x01700203 MAJOR TRUE FALSE 0x01700301 NONE FALSE FALSE 0x01700302 NONE FALSE FALSE 0x01700303 85 MAJOR TRUE FALSE Message provisioning will be allowed. Unlicensed appliance(s): %(appliance_list). License successfully installed. The remote system %(remote_system_name) is connected.
Alert and Event Messages Event code 0x01700304 0x01700305 Severity MAJOR MINOR Alert raised TRUE TRUE Call home Message FALSE All data connections from the remote system %(remote_system_name) are disconnected. FALSE The remote system %(remote_system_name) has discovered no targets to open connections.
Alert and Event Messages Event code Severity Alert raised Call home 0x01700408 INFO FALSE FALSE 0x01700601 NONE FALSE FALSE 0x01700602 NONE FALSE FALSE 0x01700603 0x01700604 0x01700605 0x01700606 0x01700607 MAJOR MINOR MINOR MINOR MINOR TRUE TRUE TRUE TRUE TRUE A replication session associated with resource %(resource_name) has been deleted. A replication session for resource %(resource_name) is being created.
Alert and Event Messages Event code Severity Alert raised Call home Message 0x01800103 MAJOR TRUE FALSE All configured DNS servers are unavailable. 0x01800201 INFO FALSE FALSE 0x01800202 MINOR FALSE FALSE All configured NTP servers are available. The following NTP servers are unavailable: %(addresses). 0x01800203 MAJOR TRUE FALSE All configured NTP servers are unavailable. 0x01800301 INFO FALSE FALSE VMware vCenter server is available.
Alert and Event Messages Event code Severity Alert raised Call home 0x01800801 INFO FALSE FALSE 0x01800802 MAJOR TRUE FALSE 0x01800901 INFO FALSE FALSE Message Ethernet switch %(physical_switch_id). Data ports are connected properly to the Ethernet switches. Data ports are connected to the out of band management switch: %(connection_scheme). Node ports are properly connected to different switches.
Alert and Event Messages Event code Severity Alert raised Call home 0x01800D02 MINOR FALSE FALSE 0x01800D03 MAJOR TRUE FALSE 0x01800E01 INFO FALSE FALSE 0x01800E02 MAJOR TRUE FALSE 0x01800F01 INFO FALSE FALSE 0x01800F02 MAJOR TRUE FALSE 90 Message Ethernet switches and configured for high availability. Unable to obtain high availability information for Ethernet switches.
Alert and Event Messages Event code Severity Alert raised Call home 0x01801001 INFO FALSE FALSE 0x01801002 MAJOR TRUE FALSE 0x01801101 INFO FALSE FALSE 0x01801102 MINOR FALSE FALSE 0x01801201 INFO FALSE FALSE 0x01801202 MAJOR TRUE FALSE 0x01801301 INFO FALSE FALSE 0x01801302 MAJOR TRUE FALSE 91 Message that is too small.(according to CDP information). Minimally required MTU is %(required_mtu).
Alert and Event Messages Event code Severity Alert raised Call home 0x01801401 INFO FALSE FALSE 0x01801402 MAJOR TRUE FALSE 0x01801501 INFO FALSE FALSE 0x01801502 MAJOR TRUE FALSE 0x01801601 INFO FALSE FALSE 0x01801602 MAJOR TRUE FALSE 0x01801701 INFO FALSE FALSE 0x01801702 92 MAJOR TRUE FALSE Message MTU configuration on Ethernet switch ports that are connected to the appliance data ports is consistent across the cluster.
Alert and Event Messages Event code Severity Alert raised Call home 0x01801801 INFO FALSE FALSE 0x01801802 MAJOR TRUE FALSE 0x01801901 INFO FALSE FALSE 0x01801902 MAJOR TRUE FALSE 0x01801A01 INFO FALSE FALSE 0x01801A02 MAJOR TRUE FALSE 0x01801B01 INFO FALSE FALSE 0x01801B02 MINOR FALSE FALSE 93 Message Ethernet switch %(physical_switch_id), with an MTU %(current_mtu) that is too small.
Alert and Event Messages Event code Severity Alert raised Call home 0x01801C01 INFO FALSE FALSE 0x01801C02 MAJOR TRUE FALSE 0x01801D01 INFO FALSE FALSE 0x01801D02 MAJOR TRUE FALSE 0x01801E01 INFO FALSE FALSE 0x01801E02 MAJOR TRUE FALSE 0x01801F01 INFO FALSE FALSE 0x01801F02 94 MAJOR TRUE FALSE Message Native VLAN configuration of Ethernet switch ports the appliance data ports are connected to is consistent.
Alert and Event Messages Event code Severity Alert raised Call home 0x01802001 INFO FALSE FALSE 0x01802002 MAJOR TRUE FALSE 0x01802003 MAJOR TRUE FALSE 0x01802101 INFO FALSE FALSE 0x01802102 MAJOR TRUE FALSE 0x01802103 MAJOR TRUE FALSE 0x01802104 MAJOR TRUE FALSE 0x01802201 INFO FALSE FALSE 0x01802202 MINOR FALSE FALSE 0x01802301 INFO FALSE FALSE 95 Message (according to LLDP information). The %(local_port) speed is configured according to system requirements.
Alert and Event Messages Event code Severity Alert raised Call home 0x01802302 MAJOR TRUE FALSE 0x01802401 INFO FALSE FALSE 0x01802402 MAJOR TRUE FALSE 0x01802501 INFO FALSE FALSE 0x01802502 MAJOR TRUE FALSE 0x01802601 INFO FALSE FALSE 0x01802602 MAJOR TRUE FALSE 0x01802701 INFO FALSE FALSE 0x01802702 MAJOR TRUE FALSE 0x01802801 INFO FALSE FALSE 96 Message appliance management ports are connected to is consistent.
Alert and Event Messages Event code Severity Alert raised Call home 0x01802802 MAJOR TRUE FALSE 0x01802901 INFO FALSE FALSE 0x01802902 MINOR FALSE FALSE 0x01802903 MINOR TRUE FALSE 0x01802A01 INFO FALSE FALSE 0x01802A02 MAJOR TRUE FALSE 0x01802B01 INFO FALSE FALSE 0x01802B02 MAJOR TRUE FALSE 0x01802C01 INFO FALSE FALSE 0x01802C02 MINOR FALSE FALSE 0x01802C03 MAJOR TRUE FALSE 97 Message %(physical_switch_id) is properly configured in PortFast/EdgePort mode.
Alert and Event Messages Event code Severity Alert raised Call home 0x01802D01 INFO FALSE FALSE 0x01802D02 MAJOR TRUE FALSE 0x01802E01 INFO FALSE FALSE 0x01802E02 MINOR FALSE FALSE 0x01802E03 0x01802F01 MAJOR INFO TRUE FALSE FALSE FALSE 0x01802F02 MAJOR TRUE FALSE 0x01803001 INFO FALSE FALSE 0x01803002 MINOR FALSE FALSE 98 Message discovery of the following management network addresses: %(ping_scheme).
Alert and Event Messages Event code 0x01803003 0x01803101 Severity MAJOR INFO Alert raised TRUE FALSE Call home FALSE FALSE 0x01803102 MAJOR TRUE FALSE 0x01803201 INFO FALSE FALSE 0x01803202 MINOR FALSE FALSE 0x01803203 MAJOR TRUE FALSE 0x01803301 INFO FALSE FALSE 0x01803302 MAJOR TRUE FALSE 0x01803401 INFO FALSE FALSE 99 Message the intra-cluster management network IP addresses are not reachable via ICMP.
Alert and Event Messages Event code Severity Alert raised Call home 0x01803402 MINOR FALSE FALSE 0x01803403 MAJOR TRUE FALSE 0x01803501 INFO FALSE FALSE 0x01803502 MINOR FALSE FALSE 0x01803503 MAJOR TRUE FALSE 0x01803601 INFO FALSE FALSE Message MTU discovery of the vMotion network addresses from the node network interfaces. Unable to detect MTU size issues because some of the vMotion network IP addresses are not reachable via ICMP.
Alert and Event Messages Event code Severity Alert raised Call home 0x01803901 INFO FALSE FALSE 0x01803902 MINOR FALSE FALSE 0x01803903 MAJOR TRUE FALSE 0x01803A01 INFO FALSE FALSE 0x01803A02 MINOR FALSE FALSE Message The Ethernet switch has connectivity with its InterChassis link peer. Unable to obtain information about the connectivity to the peer switch %(physical_switch_id) via an Inter-Chassis link.
Alert and Event Messages Event code Severity Alert raised Call home 0x01803C03 MAJOR TRUE FALSE 0x01803D01 INFO FALSE FALSE 0x01803D02 MINOR FALSE FALSE 0x01803D03 0x01803E01 0x01803E02 MAJOR INFO MAJOR TRUE FALSE TRUE FALSE The version of the Distributed Virtual Switch %(dvs_name) does not match to %(dvs_version) which is required by the system. FALSE The system VM management port group %(pg_name) is configured on the Distributed Virtual Switch %(dvs_name).
Alert and Event Messages Event code Severity Alert raised Call home 0x01803F03 MAJOR TRUE FALSE 0x01804001 INFO FALSE FALSE 0x01804002 MAJOR TRUE FALSE 0x01804101 INFO FALSE FALSE 0x01804102 MINOR FALSE FALSE 0x01804103 MAJOR TRUE FALSE 0x01804201 INFO FALSE FALSE 0x01804202 103 MAJOR TRUE FALSE Message Distributed Virtual Switch %(dvs_name). The system VM management port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id).
Alert and Event Messages Event code Severity Alert raised Call home 0x01804301 INFO FALSE FALSE 0x01804302 MINOR FALSE FALSE 0x01804303 MAJOR TRUE FALSE 0x01804401 INFO FALSE FALSE 0x01804402 MAJOR TRUE FALSE 0x01804501 INFO FALSE FALSE 0x01804502 MINOR FALSE FALSE 0x01804503 MAJOR TRUE FALSE 104 Message VLAN configuration on the vMotion port group %(pg_name) is correct.
Alert and Event Messages Event code Severity Alert raised Call home 0x01804601 INFO FALSE FALSE 0x01804602 MAJOR TRUE FALSE 0x01804701 INFO FALSE FALSE 0x01804702 MINOR FALSE FALSE 0x01804703 MAJOR TRUE FALSE 0x01804801 INFO FALSE FALSE Message The storage initiator port group %(pg_name) is configured on the Distributed Virtual Switch %(dvs_name). Unable to find a storage initiator port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name).
Alert and Event Messages Event code Severity Alert raised Call home 0x01804902 MINOR FALSE FALSE 0x01804903 MAJOR TRUE FALSE 0x01804A01 INFO FALSE FALSE 0x01804A02 MAJOR TRUE FALSE 0x01804B01 INFO FALSE FALSE 0x01804B02 MINOR FALSE FALSE 0x01804B03 MAJOR TRUE FALSE 0x01804C01 INFO FALSE FALSE 0x01804C02 MAJOR TRUE FALSE 106 Message Unable to obtain information about the VLAN configuration of the storage target port group %(pg_name) on the Distributed Virtual Switch %
Alert and Event Messages Event code Severity Alert raised Call home 0x01804D01 INFO FALSE FALSE 0x01804D02 MINOR FALSE FALSE 0x01804D03 MAJOR TRUE FALSE 0x01804E01 INFO FALSE FALSE 0x01804E02 MAJOR TRUE FALSE 0x01804F01 INFO FALSE FALSE 0x01804F02 MINOR FALSE FALSE 107 Message %(pg_name) on the Distributed Virtual Switch %(dvs_name). VLAN configuration on the storage target port group %(pg_name) is correct.
Alert and Event Messages Event code Severity Alert raised Call home 0x01804F03 MAJOR TRUE FALSE 0x01805001 INFO FALSE FALSE 0x01805002 MAJOR TRUE FALSE 0x01805101 INFO FALSE FALSE 0x01805102 MINOR FALSE FALSE 0x01805103 MAJOR TRUE FALSE 0x01805201 INFO FALSE FALSE 108 Message The storage target port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id).
Alert and Event Messages Event code Severity Alert raised Call home 0x01805202 MINOR FALSE FALSE 0x01805203 MAJOR TRUE FALSE 0x01805301 INFO FALSE FALSE 0x01805302 MAJOR TRUE FALSE 0x01805401 INFO FALSE FALSE 0x01805402 MINOR FALSE FALSE 0x01805403 MAJOR TRUE FALSE 0x01805501 INFO FALSE FALSE 109 Message Unable to obtain information about port group configuration of the management VMkernel adapter %(vmk_name) configured on the ESXi host %(host_name).
Alert and Event Messages Event code Severity Alert raised Call home 0x01805502 MINOR FALSE FALSE 0x01805503 MAJOR TRUE FALSE 0x01805601 INFO FALSE FALSE 0x01805602 MAJOR TRUE FALSE 0x01805701 INFO FALSE FALSE 0x01805702 MINOR FALSE FALSE 0x01805703 MAJOR TRUE FALSE 110 Message the ESXi host %(host_name) is connected to the vMotion port group %(pg_name) of the Distributed Virtual Switch %(dvs_name).
Alert and Event Messages Event code Severity Alert raised Call home 0x01805801 INFO FALSE FALSE 0x01805802 MINOR FALSE FALSE 0x01805803 0x01805901 0x01805902 111 MAJOR INFO MAJOR TRUE FALSE TRUE Message invalid IP configuration: %(address)/%(prefix), default gateway %(gateway). The required IP settings are: default gateway %(required_gateway) and one of the following IP addresses %(required_addresses_wit h_prefix)).
Alert and Event Messages Event code Severity Alert raised Call home 0x01805A01 INFO FALSE FALSE 0x01805A02 MINOR FALSE FALSE 0x01805A03 MAJOR TRUE FALSE 0x01805B01 INFO FALSE FALSE 0x01805B02 MINOR FALSE FALSE 0x01805B03 112 MAJOR TRUE FALSE Message IP configuration on the storage initiator VMkernel adapter %(vmk_name) of the ESXi host %(host_name) is correct.
Alert and Event Messages Event code Severity Alert raised Call home 0x01805C01 INFO FALSE FALSE 0x01805C02 MAJOR TRUE FALSE 0x01805D01 INFO FALSE FALSE 0x01805D02 MAJOR TRUE FALSE 0x01806401 INFO FALSE FALSE 0x01806402 MINOR FALSE FALSE 0x01806403 MAJOR TRUE FALSE 0x01806501 INFO FALSE FALSE 0x01806502 MINOR FALSE FALSE 113 Message The default TCP/IP stack gateway is properly configured on the ESXi host %(host_name).
Alert and Event Messages Event code Severity Alert raised Call home 0x01806503 MAJOR TRUE FALSE 0x01806601 INFO FALSE FALSE 0x01806602 MINOR FALSE FALSE 0x01806603 MAJOR TRUE FALSE 0x01806701 INFO FALSE FALSE 0x01806702 MINOR FALSE FALSE 0x01806703 MAJOR TRUE FALSE 114 Message configuration of the vMotion VMkernel adapter %(vmk_name) configured on the ESXi host %(host_name).
Alert and Event Messages Event code Severity Alert raised Call home 0x01806801 INFO FALSE FALSE 0x01806802 0x01806901 MINOR INFO TRUE FALSE FALSE FALSE 0x01806902 MAJOR TRUE FALSE 0x01806A01 INFO FALSE FALSE 0x01806A02 MAJOR TRUE FALSE 0x01806B01 INFO FALSE FALSE 0x01806B02 MAJOR TRUE FALSE 115 Message invalid MTU %(current_mtu). The required MTU is %(required_mtu). Onboard management ports are properly connected to different Ethernet switches.
Alert and Event Messages Event code Severity Alert raised Call home 0x01806C01 INFO FALSE FALSE 0x01806C02 0x01806D01 0x01806D02 MAJOR INFO MINOR TRUE FALSE TRUE FALSE The time differences between the following available NTP servers is larger than required by the system: %(diff_scheme). FALSE Time difference between the node and all available NTP servers matches the system requirements.
Alert and Event Messages Event code Severity Alert raised Call home 0x01A00103 MINOR TRUE TRUE 0x01A00104 MAJOR TRUE TRUE 0x01A00105 CRITICAL TRUE TRUE 0x01A00201 NONE FALSE FALSE 0x01A00202 CRITICAL TRUE TRUE 0x01A00301 NONE FALSE FALSE 0x01A00302 NONE FALSE FALSE 0x01A00303 MINOR TRUE TRUE 0x01A00304 MAJOR TRUE TRUE 0x01A00305 117 CRITICAL TRUE TRUE Message Core database space is at or above %(space_usage) percent used and free space is considered low.
Alert and Event Messages Event code Severity Alert raised Call home 0x01A00401 NONE FALSE FALSE 0x01A00402 CRITICAL TRUE TRUE 0x01B00101 MAJOR TRUE FALSE 0x01B00102 INFO FALSE FALSE 0x01B00201 MAJOR TRUE FALSE 0x01B00202 INFO FALSE FALSE 0x01C00101 118 CRITICAL TRUE TRUE Message Database non-essential functions are operating normally. Metrics collection and any other non-essential database activity is being shutdown to prevent any corruption due to space issues.
Alert and Event Messages Event code Severity Alert raised Call home 0x01C00102 INFO FALSE FALSE 0x01C00203 CRITICAL TRUE TRUE 0x01C00204 INFO FALSE FALSE 0x01C00301 CRITICAL TRUE FALSE 0x01C00302 CRITICAL TRUE FALSE 0x01C00303 INFO FALSE FALSE 0x01C00401 MAJOR TRUE FALSE 0x01C00402 119 INFO FALSE FALSE Message unavailable once the appliance reaches 100% capacity. The consumed storage space of appliance %(appliance_id) is below 96% capacity.