Release Notes

Known Issues 27
Issue ID
Functional
Area
Description Workaround/Resolution
MDT-285058 Hardware In some cases, after the appliance stops
servicing IOs and then goes back online,
the "stopped servicing IOs" alert is not
cleared automatically even though the
system is working correctly.
If the hosts are connected and the IOs are
being serviced, the alert can be ignored.
MDT-117061 Hardware When beginning cluster creation, the
hardware status is incorrectly indicated as
not configured for clustering.
Wait a few minutes and try again.
MDT-190232 Hardware The svc_node shutdown command may
reboot the node instead of powering it
off.
Run the svc_node shutdown command
again when the node has finished rebooting.
MDT-263147 Hardware If you add an appliance to a cluster when
another appliance in the cluster is
powered off, the add appliance operation
will fail.
None
MDT-260313 Hardware One or both nodes may not automatically
power back on after a short AC power
outage of less than 50 seconds. The
appliance should power on properly after
the first AC failure, but it is vulnerable to
subsequent short AC failures.
If only a single node does not power back
up PowerStore Manager will display a major
alert for the impacted BaseEnclosure-Node -
with the following message "Node has been
physically removed or shut down" (Event
code 0x00304404). Log into the system
service account and use the "svc_node
power_on" command to power up the peer
node.
If neither node of the appliance is accessible
after 30 minutes following a short AC power
failure the appliance will need to be reset.
To reset the appliance, remove the AC
power for at least 120 seconds and then
restore AC power and both nodes should
power up and return to service within 30
minutes.
MDT-137439 Import If an import from a Unity or VNX2 system
to PowerStore is cancelled by the user or
fails for some reason, it is possible that
subsequent attempts to import the
volume will also fail.
Remove the Unity or VNX2 as a remote
system and then add it again. This action will
clear the issue and allow the import to
proceed.
MDT-252560 Import Import of a volume failed with the error
"Import failed because the mirror service
could not be enabled on the Destination
volume".
Run the verify operation on the remote
system to recover data connections. Once
the remote system verify operation
completes successfully, try the import
operation again.