Release Notes

28 Known Issues
Issue ID
Functional
Area
Description Workaround/Resolution
MDT-258429 Import If multiple storage networks are
configured on PowerStore and each of
these networks has a dedicated Global
Storage Discovery IP Address (GSDIP),
non-disruptive import fails with Error
Code 0xE0301002002C.
See Dell knowledge base article 000184766:
PowerStore: Non-disruptive Import failure
when more than one Global Storage
Discovery IP Address is configured.
MDT-286363 Internal
Migration
After migrating volumes, removing an
appliance from the cluster failed with the
following error message: "Failed to delete
target port group."
Contact your service provider.
MDT-290965 Internal
Migration
In a PowerStore multi-appliance cluster,
internal migration of volumes or volume
groups used by Microsoft Windows
Failover Cluster may result in hosts losing
access to storage.
Internal migration of volumes or volume
groups used by Microsoft Windows Failover
cluster must be done with no active I/O
during cutover. I/O can be quiesced by
powering down the host or unmapping the
volumes. Failure to quiesce I/O during
cutover could lead to data unavailability.
MDT-285903 Internal
Migration
The migration failed due to an High
Availability (HA) event and a system
snapshot remains on the migration source
object.
Contact your service provider to clean up
the remaining snapshot.
MDT-167020 Internal
Migration
Migration of a storage resource failed with
the error "Transit object with Handle <id>
: status online on only one node." One of
the nodes of the migration source
appliance was down when the
synchronize phase started. Both nodes
must be online for migration.
Bring the offline node back online and then
try the migration again.
MDT-140927 Internal
Migration
After a volume is migrated, there may be
a dip in capacity and performance metrics
reporting for that volume at the end of
the migration operation.
None
MDT-273051 Internal
Migration
If all objects are selected, or more objects
are selected than the destination has the
capacity for, a failure message may appear
when attempting to migrate those objects
from one appliance to another using the
assisted migration workflow.
Select objects individually and migrate
volumes by using the manual migration
workflow instead of using the assisted
migration workflow.
MDT-263177 Internal
Migration
One or more vVols might be inaccessible
to the host after an internal migration
completes successfully.
The inaccessible vVols can be made
accessible to the host by manually updating
the compute resource within vMotion. For
details, see Dell knowledge base article
000105896: PowerStore: Supported Host
operating system for Non-Disruptive
migration of Storage resources.