Release Notes

Known Issues 31
Issue ID
Functional
Area
Description Workaround/Resolution
MDT-249810 Monitoring If the total system capacity is below 10TB,
free page tables are not replenished as
this would consume space that might not
be required and waste free pages. The
lack of free pages in the table causes a
performance impact for writes. For better
performance, more capacity should be
added.
Make sure that the system capacity is higher
than 10TB.
MDT-146346 Notifications and
Alerts
Some hardware alert states may persist
for a short time after the health of the
object has been restored. The alert states
eventually resolve with the correct state.
None
MDT-245640 PowerStore
Manager (GUI)
When rebooting or powering off a node
from PowerStore Manager, the system
may not display any acknowledgement
that the process has begun. The Reboot or
Power Down button may still appear
clickable. Despite the lack of
acknowledgment, the operation will be
triggered successfully after a single click of
the button.
None
MDT-293294 PowerStore
Manager (GUI)
In PowerStore Manager during the
selection of storage objects step of a
Hardware appliance Migrate action
workflow, an unexpected exception can
appear if one of the following occurs:
While All Available Objects and Eligible For
Migration objects are selected, a user
selects Not Eligible For Migration objects
and then selects Select Objects Manually
for migration.
While Select Objects Manually and Eligible
For Migration objects are selected, a user
selects Not Eligible For Migration objects
and then selects All Available Objects for
migration.
If an unexpected exception appears, reload
the page to return to the Hardware page
and try to migrate from the appliance again.
MDT-118394 PowerStore
Manager (GUI)
Uploading an upgrade package that is
larger than 4 GB with Microsoft Edge or
Internet Explorer fails.
Try again with a different browser.
MDT-163489 PowerStore
Manager (GUI)
Once a node is replaced, the new node
hardware information does not appear in
PowerStore Manager immediately.
After replacing a node, wait up to 30
minutes for the PowerStore Manager screen
to reflect the update.