Table 3-37 shows power consumption data for the PoE-enabled switches.
The PoE power budget for each interface is controlled by the switch firmware.
The administrator can limit the power supplied on a port or prioritize power
to some ports over others. Table 3-38 shows the power budget data.
Table 3-37. Dell EMC Networking N3000 Series Power Consumption
Model Input
Voltage
Power Supply
Configuration
Max Steady
Current
Consumption (A)
Max Steady
Power (W)
Dell EMC
Networking
N3024P
100V PSU1+PSU2 13.1 1310.0
110V PSU1+PSU2 11.7 1287.0
120V PSU1+PSU2 10.6 1272.0
220V PSU1+PSU2 5.6 1232.0
240V PSU1+PSU2 5.2 1240.8
Dell EMC
Networking
N3048P/N30
48EP-ON
100V PSU1+PSU2 21.8 2180.0
110V PSU1+PSU2 19.5 2145.0
120V PSU1+PSU2 17.8 2136.0
220V PSU1+PSU2 9.31 2048.2
240V PSU1+PSU2 8.6 2064.0