Auto enables the switch to deliver power to the powered device. The power
inline management parameter should be set to class-based mode to enable
power negotiation via LLDP-MED. Dell EMC Networking PoE-enabled ports
should not be connected to other Power Sourcing Equipment (PSE) with PoE
enabled. If the switch detects PSE equipment supplying power to a port, PoE
power is disabled on the port. If a port supplying power issues an input power
detected (0x24) status and no device is attached, the port should not be used
as a possible short may exist.
Default Value
The default value is auto, that is, device discovery is enabled and the port is
capable of delivering power.
Examples
console(config)#interface gigabitethernet 1/0/1
console(config-if-Gi1/0/1)# power inline auto
power inline detection
Use the power inline detection command to configure the detection type
that tells which types of PD’s will be detected and powered by the switch. Use
the no form of this command to set the detection type to the default.
Syntax
power inline detection [unit unit-id]{dot3at|dot3at+legacy}
no power inline detection
dot3at—IEEE 802.3at 4-point detection only.
dot3at+legacy—IEEE 802.3at 4-point detection followed by legacy
capacitive detection.
unit unit-id—The specific stack member to be configured.
Default Configuration
The default value is dot3at+legacy.