Users Guide

Switch Management Commands 2087
Admin Displays the requested power delivery state, which is either
Auto or Never.
Status Displays the operational state which is one of Off, Searching,
On, Faulty, Testing, TestFail, Requesting, or Overload.
Class
(Measured/Assigned)
Displays the class power range for a single interface or the
class, which is one of Class0, Class1, Class2, Class3, Class4,
Class5, Class6, Class7, Class8, or Unknown.
Total Power The switch input power (watts).
Threshold Power The power draw that will cross the power threshold (watts).
Consumed Power The power fed to the powered devices (watts).
Usage Threshold The percentage of total power available minus the reserved
power.
Power Management
Mode
The configured power management mode.
Power Detection
Mode
The configured power detection scheme.
High Availability
Mode
The configured mode for perpetual and fast PoE.
Overload Counter A count of the number of times an overload condition was
detected.
Short Counter A count of the number of times the port was turned off
because a short was detected.
Denied Counter A count of the number of times the port was turned off due to
power management.
Absent Counter A count of the number of times the port failed capacitor or
resistor detection.
Invalid Signature A count of the number of times an invalid signature was
detected.
Input Voltage The momentary voltage being fed to the PoE chip by the
main power supply (in volts).
Input Current The momentary current being fed to the PoE chip by the
main power supply (in milliamps).