Users Guide

Switch Management Commands 2097
show rmon alarms
Use the show rmon alarms command in User Exec mode to display the
alarms summary table.
Syntax
show rmon alarms
Default Configuration
This command has no arguments or keywords.
Sample Type The method of sampling the variable and calculating the value
compared against the thresholds. If the value is absolute, the
value of the variable is compared directly with the thresholds at
the end of the sampling interval. If the value is delta, the value of
the variable at the last sample is subtracted from the current
value, and the difference compared with the thresholds.
Startup Alarm The alarm that may be sent when this entry is first set. If the first
sample is greater than or equal to the rising threshold, and startup
alarm is equal to rising or rising and falling, then a single rising
alarm is generated. If the first sample is less than or equal to the
falling threshold, and startup alarm is equal falling or rising and
falling, then a single falling alarm is generated.
Rising Threshold A sampled statistic threshold. When the current sampled value is
greater than or equal to this threshold, and the value at the last
sampling interval is less than this threshold, a single event is
generated.
Falling Threshold A sampled statistic threshold. When the current sampled value is
less than or equal to this threshold, and the value at the last
sampling interval is greater than this threshold, a single event is
generated.
Rising Event The event index used when a rising threshold is crossed.
Falling Event The event index used when a falling threshold is crossed.
Owner The entity that configured this entry.
Field Description