Users Guide

Switch Management Commands 2287
Command Mode
Privileged Exec mode, Global Configuration mode and all Configuration
submodes
User Guidelines
The Global Status Parameters for NSF are explained as follows:
Parameter Description Range Default
NSF
Administrative
Status
Whether nonstop forwarding is
administratively enabled or disabled
Enabled
Disabled
Enabled
NSF Operational
Status
Indicates whether NSF is enabled
on the stack.
Enabled
Disabled
None
Last Startup
Reason
The type of activation that caused
the software to start the last time.
There are four options. “Power-On”
means that the switch rebooted.
This could have been caused by a
power cycle or an administrative
“Reload” command.
“Administrative Move” means that
the administrator issued a
command for the stand-by manager
to take over. “Warm-Auto-Restart”
means that the primary
management card restarted due to a
failure, and the system executed a
nonstop forwarding failover. “Cold-
Auto-Restart” means that the
system switched from the active
manager to the backup manager and
was unable to maintain user data
traffic. This is usually caused by
multiple failures occurring close
together.
Power-On
Administrative-
Move
Warm-Auto-
Restart
Cold-Auto-
Restart
None