Security Commands 990
Command Mode
Global Configuration mode
User Guidelines
Log messages at or above this severity level are considered urgent. By default,
Emergency and Alert log messages are considered urgent. Urgent log
messages are e-mailed immediately, one log message per e-mail message, and
do not wait for the log time to expire. Urgent log messages are not e-mailed
unless you enable e-mail alerting with the logging email command.
logging email message-type to-addr
Use the logging email message-type to-addr command in Global
Configuration mode to configure the To address field of the e-mail. The
message types supported are urgent, non-urgent, and both. For each
supported severity level, multiple e-mail addresses can be configured. For
example, for urgent type of messages, there could be multiple addresses
configured.
Syntax
logging email message-type {urgent | non-urgent | both} to-addr to-email-
addr
no logging email to-addr to-addr message-type
no logging email message-type {urgent | non-urgent | both} to-addr
to-
email-addr
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration
User Guidelines
The to-email-addr is the address to which the email is sent.