CLI Guide

Switch Management Commands 2097
Example
This example configures forced 60W 4-pair power mode on interface Gi1/0/1
console#configure
console(config)#interface gi/10/1
console(config-if-Gi1/0/1)#power inline four-pair forced
power inline limit
Use the power inline limit command to configure a specific power limit for a
port. Use the no form of this command to set the power limit to the default.
Syntax
power inline limit user-defined limit
no power inline limit
• user-defined limit—Allows the port to draw up to user-defined value. The
range is 3000-30000 milliwatts (mW) in two-pair mode. In four-pair mode,
the range is 3000-60000 milliwatts.
Default Configuration
In two-pair mode, the default power limit is 30000 milliwatts. In four-pair
mode, the default power limit is 60000 milliwatts.
Command Mode
Interface Configuration
User Guidelines
This command is not available on the N2200PX-ON Series switches.
User defined limits are only operational if the power management mode is
configured as static. By default, the power management mode is dynamic. If
the operator attempts to set a user-defined limit and the power management
mode is not configured as static, a warning is issued. On systems that support
four-pair power, the UI does not check the limit against the port capability or
the configuration. To deliver 60W power, ensure that the port is configured in
four-pair mode.