CLI Guide

Layer 2 Switching Commands 411
Command History
Introduced in version 6.2.0.1 firmware. Updated in version 6.3.0.1 firmware.
Updated in version 6.5 firmware.
Example
The following example shows the output for a 1G interface:
console#show interfaces gi1/0/1
Interface Name : .............................. Gi1/0/1
SOC Hardware Info :............................ BCM56342_A0
Link Status : ................................. Up/Up
Keepalive Enabled.............................. TRUE
Err-disable Cause : ........................... None
VLAN Membership Mode: ......................... Trunk Mode
VLAN Membership: .............................. (1),2-3,101-113,813,3232
MTU Size : .................................... 1518
Port Mode [Duplex] : .......................... Full
Port Speed : .................................. 1000
Link Flaps : .................................. 0
Link Debounce Flaps : ......................... 0
Auto-Negotation Status : ...................... Auto
Burned MAC Address : .......................... 001E.C9DE.B110
L3 MAC Address................................. 001E.C9DE.B112
Sample load interval : ........................ 300
Receive Rate Bits/Sec : ....................... 784
Receive Rate Packets/Sec : .................... 1
Receive Percent Utilization : ................. 0
Transmit Rate Bits/Sec : ...................... 1344
Transmit Rate Packets/Sec : ................... 1
Multicast
Storm
mcast-storm Multicast storm auto-recovery.
SFP Mismatch sfp-mismatch SFP mismatch auto-recovery.
SFP Plus
Mismatch
sfpplus-
mismatch
SFP+ transceiver inserted in SFP port auto-
recovery.
Spanning Tree spanning-tree Spanning-tree auto-recovery.
UDLD udld UDLD auto-recovery.
Unicast Storm ucast-storm Unicast storm auto-recovery.
Term Parameter Description