Users Guide

Stacking 237
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the stack master.
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
Preconfiguring a Stack Member
To preconfigure a stack member before connecting the physical unit to the
stack, use the show supported switchtype command to obtain the switch
model ID (SID) of the unit to be added.
The example in this section demonstrates pre-configuring a stand-alone Dell
EMC Networking N-Series switch.
To configure the switch:
1
View the list of SIDs to determine which SID identifies the switch to
preconfigure. The following is the output on the switches. The supported
switch types vary by switch series and loaded image.
console#show supported switchtype
SID Switch Model ID
--- --------------------------------
1 N3024
2 N3024F
3 N3024P
4 N3048
5 N3048P
6 N3048EP-ON
7 N3132PX-ON
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-in
Model ID
Switch
Status
Code
Version
--- --------- ------- -------- --------- ------- --------
1 Mgmt Sw N2128PX N2128PX OK 6.3.6.4
3 Stack Mbr N2128PX N2128PX OK 6.3.6.4
4 Stack Mbr N2128PX N2128PX OK 6.3.6.4