Administrator Guide

Switch Management Commands 2018
the show power inline command shows the actual reported power draw and
does not take into account the class reserved power. Configure the powered
device to send LLDP-MED packets in this mode. It may take up to 60
seconds to power up a device in class based management mode as LLDP-
MED packets need to be exchanged in order to configure the desired power.
Class-based power management allocates power based on the class selected
by the device using LLDP-MED. Power is supplied to the device in class
mode per the following table:
There are three power banks on a switch: one for the fixed power supply, one
for the external power supply (EPS) and one for both. The power limits are
shown in the following table.
Class Usage Current (mA) Power (Watts)
0Default 600 34.2
1Optional 350 15.4
2Optional 350 15.4
3Optional 350 15.4
4 Valid for 802.3at (Type 2) devices, not
supported for 802.3af devices
600 34.2
2CSNXXX_SWUM204.book Page 2018 Monday, January 25, 2016 1:25 PM