Administrator Guide

Switch Management Commands 2103
Syntax
sflow
rcvr_index
destination {
ip-address
[
port
] | maxdatagram
size
| owner
"owner_string"
{notimeout|timeout rcvr_timeout}
no sflow
rcvr_index
destination [
ip-address
| maxdatagram | owner ]
rcvr_index
The index of this sFlow Receiver (Range: 1–8).
ip-address
The sFlow receiver IP address. If set to 0.0.0.0, no sFlow
datagrams will be sent.
size
The maximum number of data bytes that can be sent in a single
sample datagram. The management entity should set this value to avoid
fragmentation of the sFlow datagrams. (Range: 200–9116 bytes).
owner_string
The identity string for the receiver. A receiver is not
enabled until the owner string is assigned. The default is an empty string.
The identity string must be set before assigning a receiver to a sampler or
poller. (Range: 1–127 characters).
rcvr_timeout
The time, in seconds, remaining before the sampler or
poller is released and stops sending samples to the receiver. Setting a value
of 0 for the timeout value permanently configures the sflow receiver. Use
the no form of the command to remove permanently configured receivers.
A management entity wanting to maintain control of the sampler is
responsible for setting a new value before the old one expires. (Range:
0–4294967295 seconds).
port
The destination Layer4 UDP port for sFlow datagrams. (Range:
1–65535).
Default Configuration
No receivers are configured by default.
The default IP address is 0.0.0.0
The default maximum datagram size is 1400.
The default owner string is the empty string.
The default receiver timeout is 0.
The default destination port is 6343.
2CSNXXX_SWUM204.book Page 2103 Monday, January 25, 2016 1:25 PM