Administrator Guide

Switch Management Commands 2163
no logging buffered
severity–level
—(Optional) The number or name of the desired severity
level. Range:
[0 | emergencies]
[1 | alerts]
[2 | critical]
[3 | errors]
[4 | warnings]
[5 | notifications]
[6 | informational]
[7 | debugging]
Default Configuration
The default value for
level
is
info.
Command Mode
Global Configuration mode
User Guidelines
All the syslog messages are logged to the internal buffer. This command limits
the commands displayed to the user. Debug level messages are intended for
use by support personnel. The output is voluminous, cryptic, and because of
the large number of messages generated, can adversely affect switch
operations. Only set the logging level to debug under the direction of support
personnel.
Example
The following example limits syslog messages collected in the internal buffer
to those of severity level "error" and above (numerically lower).
console(config)#logging buffered error