Administrator Guide

Layer 2 Switching Commands 417
Command Modes
User Exec, Privileged Exec modes.
User Guidelines
This command only supports the display of 10G and 40G transceivers.
Example
The following example shows the qualifications status of the optics on the
switch.
console#show interfaces transceiver
Port Dell Qualified
------------- ----------------
Te1/0/9 Yes
Te1/0/11 Yes
Te1/0/13 N/A
Te1/0/15 No
Te1/0/17 No
The following example shows static parameters of the optics along with the
qualifications status.
console#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
------------ ------- --------------- -------------------- --------------
Te1/0/9 SFP+ 10GBASE-LRM ANF0L5J Yes
Te1/0/11 SFP+ 10GBASE-LRM ANF0L5R Yes
Te1/0/13 SFP 1GBASE-SX PCC1PT5 N/A
Te1/0/15 SFP+ 10GBASE-SR AD1125A002R No
Te1/0/17 SFP+ 10GBASE-SR AD0815E00PC No
show statistics
Use the show statistics command in Privileged Exec mode to display detailed
statistics for a specific port or for the entire switch.
2CSNXXX_SWUM204.book Page 417 Monday, January 25, 2016 1:25 PM