Administrator Guide

Layer 2 Switching Commands 437
hold-time
—The time in seconds to maintain the data for a missing MEP
before removing the data. The default value is 600 seconds.
Default Configuration
No MEPs are preconfigured.
Command Mode
Interface Configuration
User Guidelines
The hold time should generally be less than the CCM message interval.
Example
The following example sets the hold time for maintaining internal
information regarding a missing MEP.
console(config)#ethernet cfm mep archive-hold-time 1200
ethernet cfm mip level
Use the ethernet cfm mip level command in Interface Configuration mode
to create a Maintenance Intermediate Point (MIP) at the specified level. The
MEPs are configured per Maintenance Domain per interface. Use the no
form of the command to delete a MIP.
Syntax
ethernet cfm mip level
0-7
level
—Maintenance association level
Default Configuration
No MIPs are preconfigured.
Command Mode
Interface Configuration