Administrator Guide

Layer 2 Switching Commands 599
keepalive (Global Config)
Use the keepalive command in Global Configuration mode to configure the
loop protection timer and packet count. Use the no form of the command to
return the configuration to the defaults.
Syntax
keepalive [
period
[
count
] ]
no keepalive
period
– Configures the interval for the transmission of keepalive packets.
Default: 10 seconds
count
Configures the number of consecutive CTP packets addressed to
and received by the local switch before the interface is error disabled.
Default: 3 packets.
Default Configuration
Loop protection is enabled on all interfaces by default.
The default period is 10 seconds.
The default count is 3 packets.
Command Mode
Global Configuration mode
User Guidelines
Loop protect must be enabled individually on a physical interface.
If only the period parameter is specified, the count parameter remains
unchanged.
Loop protection may only be enabled on physical interfaces, not on port
channels or any virtual interfaces.
Command History
Implemented in version 6.3.0.1 firmware.
2CSNXXX_SWUM204.book Page 599 Monday, January 25, 2016 1:25 PM