Setup Guide

8
To clear the configuration and reset the switch, press the reset button for at
least eight seconds. The saved configuration is cleared and the switch reboots.
The switch then starts the autoconfiguration process.
N2200-ON Series Port and System LEDs
The front panel contains light emitting diodes (LEDs) that indicate the
status of system temperature, port links, power supplies, fans, stacking, and
the overall system status. A locator beacon capability is also present on the
system LEDs. See
N2200-ON Series LED Definitions
for more information.
N2200-ON Series Stack Master LED and Stack Number Display
When a switch within a stack is the master unit, the stack master LED is solid
green. If the stack master LED is off, the stack member is not the master unit.
The stack number LCD displays the unit number for the stack member. If a
switch is not part of a stack (in other words, it is a stack of one switch), the
stack master LED is illuminated, and the unit number is displayed.
N2200-ON Series Power Supplies
The Dell EMC Networking N2224X-ON/N2248X-ON switches have a field-
replaceable 550W power supply (DS-550 AC). An additional field-replaceable
power supply may be added to support redundancy.
The Dell EMC Networking N2224PX-ON switches have a field-replaceable
1050-watt power supply (DPS-1050 AC) feeding up to 16x30W PoE and
2x60W devices at full power (712W). The Dell EMC Networking N2248PX-
ON switches have an internal 1050W power supply (DPS-1050 AC) feeding
up to 16x30W PoE devices and 1Xx60W at full power (624W).
In both PoE models, additional field replaceable 1050W, 1300W, or 1600W
power supplies are available to support redundancy or to supply full front
panel demand.
Table 1-1 shows power budget data.
Table 1-1. Dell EMC Networking N2200PX-ON Series PoE Power Budget Limit
One PSU Two PSUs (2x1050W)
Model Name PoE Power
Budget
Power
Turn-on Limitation
PoE Power
Budget
Power
Turn-on Limitation