Users Guide

Switch Management Commands 2086
show power inline
Use the show power inline command to report current PoE configuration and
status. If no port is specified, the command displays global configuration and
status of all the ports. If a port is specified, then the command displays the
details for the single port. Use the detailed parameter to show power limits,
detection type and high power mode for the interface. The detailed
parameter is not available on N2200 and N3200 devices.
Syntax
show power inline [interface-id] [detailed]
interface-id—Any PoE-capable Ethernet interface. See
Interface Naming
Conventions
for interface representation.
Command Mode
Privileged Exec mode, Global Configuration mode and all Configuration
submodes
User Guidelines
Ports configured in static mode will always show as Class 0 regardless of the
actual PD type.
The power status column shows Off for ports that are administratively or
error disabled.
The Power column shows the actual power drawn, not the configured value.
If a port supplying power detects PSE equipment, the power to the port is
shut off. If a powered port shows input power detected status (0x24), and no
device is attached, the port should not be used as a possible short may exist.
The PoE controller returns the Total Power Consumed value in Watts. For
this reason, Total Power Consumption value displayed might not exactly
match the sum of power in milliwatts consumed by various Powered Devices.
The displayed information includes the following:
Field Description
Priority Displays the configured priority, which is one of Critical,
High, Medium, or Low.