Setup Guide

0:_bcm_esw_linkscan_update_port: Port xe45: Link Up with Speed 0M!
0:_bcm_esw_linkscan_update_port: Port xe46: Link Up with Speed 0M!
0:_bcm_esw_linkscan_update_port: Port xe47: Link Up with Speed 0M!
Test link_status_test for NPU 0 .......................... Passed
vlan 1 ports cpu,ce,xe (0x000000000000000000000000000000000000000000000000007fffffffffffff),
untagged ce,xe (0x000000000000000000000000000000000000000000000000007ffffffffffffe)
MCAST_FLOOD_UNKNOWN
vlan 1000 ports xe0-xe1
(0x0000000000000000000000000000000000000000000000000000000600000000), untagged xe0-xe1
(0x0000000000000000000000000000000000000000000000000000000600000000) MCAST_FLOOD_UNKNOWN
vlan 1001 ports xe1-xe2
(0x0000000000000000000000000000000000000000000000000000001200000000), untagged xe1-xe2
(0x0000000000000000000000000000000000000000000000000000001200000000) MCAST_FLOOD_UNKNOWN
.
.
.
vlan 1003 ports ce0,xe48
(0x0000000000000000000000000000000000000000000000000020000100000000), untagged ce0,xe48
(0x0000000000000000000000000000000000000000000000000020000100000000) MCAST_FLOOD_UNKNOWN
vlan 1004 ports ce
(0x0000000000000000000000000000000000000000000000000060000000000000), untagged ce
(0x0000000000000000000000000000000000000000000000000060000000000000) MCAST_FLOOD_UNKNOWN
vlan 1005 ports ce1
(0x0000000000000000000000000000000000000000000000000040000000000000), untagged ce1
(0x0000000000000000000000000000000000000000000000000040000000000000) MCAST_FLOOD_UNKNOWN
Test uplink_snake_traffic_test for NPU 0 .......................... Passed
Test uplink_prbs_mac_test for NPU 0 .......................... SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0 .......................... SKIPPED <<<---
NPU tests: Overall test results------------------ >>>> PASSED
EDA: Overall test results ----------------------------- >>> Passed
root@dellemc-diag-os:~#
Verbose mode
Use the following steps to enable and set the verbose level.
1. Set the Verbose level with a value of 0–3 using bits 4 and 5 of the EDA control reg (0x55).
For example, to set the verbose level to 2, set bit 5–1 (5=1) and bit 4–0 (4=0).
root@dellemc-diag-os:~# nvramtool --write --reg=0x55 --val=0x25
The value is written in hexadecimal. The xx10x1xx shows the bit positions of 2, 4&5, and bit 0 on the right.
2. Enable Verbose mode by setting bit 2 of the same reg to 1.
NOTE: If you disable Verbose mode, or bit 2 of reg 0x55 is set to 0, the default verbosity level is 0/zero.
EDA control reg (0x55):
5:4—EDA Verbose Level = 0/1/2/3 or verbosity level 0, 1, 2, or 3
3—EDA Extended Tests
2—EDA Verbose Mode = 0/1 (0=disabled; 1=enabled)
1—EDA stop on Error
0—EDA Enable
NOTE:
If you do not need the Verbose mode settings to persist through reboots, you can use the environment variable
method to enable Verbose Mode.
export VERB_LEVEL=<setting 0,1,2 or 3>
To clear the environment variable, use the unset VERB_LEVEL command.
28 Dell EMC DIAG-OS tools