Setup Guide

Test uplink_prbs_ext_test for NPU 0 ......... SKIPPED <<<---
NPU tests ................................... Passed
CPU traffic with adjacent loopback
Tests the traffic sent from the CPU internally generated packet to the front-end ports which are connected with direct attach cables
(DACs) or optics with cables connected top-to-bottom.
Connect all the ports with DACs or 40G/100G optics with cables.
nputool -i -t 1 -T cpu_adj
nputool --init --test 1 --traffic cpu_adj
root@dell-diag-os:~# nputool -i -t 1 -T cpu_adj
DMA pool size: 16777216
PCI unit 0: Dev 0x8375, Rev 0x11, Chip BCM88375_B0, Driver BCM88375_B0
sysconf_probe successful
global_sal_config successful
*** 1 BCM devices are detected
Diag NPU initialization over
Test link_status_test for NPU 0 ............ SKIPPED <<<---
Test snake_traffic_test for NPU 0 ............ Passed
Test prbs_mac_test for NPU 0 ............ SKIPPED <<<---
Test prbs_ext_test for NPU 0 ............ SKIPPED <<<---
Test uplink_link_status_test for NPU 0 ............ SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0 ............ SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0 ............ SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0 ............ SKIPPED <<<---
NPU tests .......................................... Passed
root@dell-diag-os:~#
root@dell-diag-os:~# nputool -init -test 1 -traffic cpu_adj
DMA pool size: 16777216
PCI unit 0: Dev 0x8375, Rev 0x11, Chip BCM88375_B0, Driver BCM88375_B0
sysconf_probe successful
global_sal_config successful
*** 1 BCM devices are detected
Diag NPU initialization over
Test link_status_test for NPU 0 ............. SKIPPED <<<---
Test snake_traffic_test for NPU 0 ............. Passed
Test prbs_mac_test for NPU 0 ............. SKIPPED <<<---
Test prbs_ext_test for NPU 0 ............. SKIPPED <<<---
Test uplink_link_status_test for NPU 0 ............. SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0 ............. SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0 ............. SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0 ............. SKIPPED <<<---
NPU tests ........................................... Passed
root@dell-diag-os:~#
IXIA traffic with external loopback
Tests the traffic sent from IXIA to port-1 and to the front-end ports which are connected with external Loopback optics.
Connect the first port to IXIA and all other ports with QSFP28 Loopback optics.
nputool -i -t 1 -T ixia_self -d
nputool --init --test 1 --traffic ixia_self -d
These commands configure the virtual local area network (VLAN) and after the BCM.0> shell displays, send the traffic from IXIA. To
verify the counters, run the show c command in the BCM shell.
IXIA traffic with adjacent loopback
Tests the traffic sent from IXIA to the front-end ports which are connected with DACs or optics with cables connected top-to-bottom.
Connect the first two ports to IXIA and all the remaining ports with DACs or 40G/100G optics with cables.
nputool –i –t 1 –T ixia_adj
nputool --init --test 1 --traffic ixia_adj
The previous commands configure the VLAN and after the BCM.0> shell displays. To verify the counters, run the show c command in
the BCM shell.
48
Dell EMC DIAG-OS tools