Administrator Guide

Switch Management Commands 2238
Last Startup
Reason
The type of activation that caused
the software to start the last time.
There are four options. “Power-On”
means that the switch rebooted.
This could have been caused by a
power cycle or an administrative
“Reload” command.
“Administrative Move” means that
the administrator issued a
command for the stand-by manager
to take over. “Warm-Auto-Restart”
means that the primary
management card restarted due to a
failure, and the system executed a
nonstop forwarding failover. “Cold-
Auto-Restart” means that the
system switched from the active
manager to the backup manager and
was unable to maintain user data
traffic. This is usually caused by
multiple failures occurring close
together.
Power-On
Administrative-
Move
Warm-Auto-
Restart
Cold-Auto-
Restart
None
Time Since Last
Restart
Time since the current management
card became the active management
card. For the backup manager, the
value is set to 0d 00:00:00
Time Stamp 0d
00:00:00
Restart in progress Whether a restart is in progress. A
restart is not considered complete
until all hardware tables have been
fully reconciled.
Yes or No
Warm Restart
Ready
Whether the initial full checkpoint
has finished
Yes or No
Status Whether the running configuration
on the backup unit includes all
changes made on the management
unit.
Current or Stale
Parameter Description Range Default