Dell Command Line Reference Guide for the S3048– ON System 9.8(0.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide............................................................................................................ 39 Objectives........................................................................................................................................................................ 39 Audience..........................................................................................................................................................................
Control and Monitoring................................................................................................. 82 banner exec......................................................................................................................................................................82 banner login......................................................................................................................................................................83 banner motd...............
show environment.......................................................................................................................................................... 125 show inventory................................................................................................................................................................127 show login statistics..........................................................................................................................................
debug dot1x..................................................................................................................................................................... 171 dot1x auth-fail-vlan..........................................................................................................................................................172 dot1x auth-server........................................................................................................................................
permit udp................................................................................................................................................................ 218 resequence access-list............................................................................................................................................. 220 seq......................................................................................................................................................................
set metric................................................................................................................................................................. 261 set metric-type........................................................................................................................................................ 262 set next-hop........................................................................................................................................................
8 Access Control List (ACL) VLAN Groups and Content Addressable Memory (CAM).....311 member vlan....................................................................................................................................................................311 ip access-group............................................................................................................................................................... 311 show acl-vlan-group .................................................
bgp dampening........................................................................................................................................................ 348 bgp default local-preference.....................................................................................................................................349 bgp dmzlink-bw.......................................................................................................................................................
neighbor route-reflector-client................................................................................................................................. 390 neighbor sender-side-loopdetect.............................................................................................................................. 391 neighbor send-community........................................................................................................................................392 neighbor shutdown.....
IPv6 BGP Commands.................................................................................................................................................... 444 clear ip bgp ipv6 unicast soft....................................................................................................................................444 debug ip bgp ipv6 unicast soft-reconfiguration........................................................................................................ 445 ipv6 prefix-list.....
show hardware stack-unit buffer-stats-snapshot (Total Buffer Information)............................................................ 485 show hardware system-flow.....................................................................................................................................487 show hardware counters interface .......................................................................................................................... 489 show hardware vlan-counters.........................
ip dhcp snooping verify mac-address........................................................................................................................516 ipv6 dhcp snooping verify mac-address.................................................................................................................... 517 ip helper-address.......................................................................................................................................................517 ipv6 helper-address....
disable............................................................................................................................................................................554 garp timers.................................................................................................................................................................... 555 gvrp enable..........................................................................................................................................
ip igmp snooping flood............................................................................................................................................. 593 ip igmp snooping last-member-query-interval.......................................................................................................... 594 ip igmp snooping mrouter.........................................................................................................................................595 ip igmp snooping querier.
switchport................................................................................................................................................................653 Egress Interface Selection (EIS) Commands..................................................................................................................654 application................................................................................................................................................................
arp retries.......................................................................................................................................................................688 arp timeout.................................................................................................................................................................... 689 clear arp-cache.......................................................................................................................................
show ip route summary.................................................................................................................................................. 744 show ip traffic.................................................................................................................................................................745 show tcp statistics.............................................................................................................................................
clns host.........................................................................................................................................................................788 debug isis....................................................................................................................................................................... 789 debug isis adj-packets..............................................................................................................................
net................................................................................................................................................................................. 825 passive-interface............................................................................................................................................................825 redistribute..........................................................................................................................................
name.........................................................................................................................................................................871 show config..............................................................................................................................................................872 show vlan.........................................................................................................................................................
advertise med voice.................................................................................................................................................909 advertise med voice-signaling...................................................................................................................................910 32 Microsoft Network Load Balancing............................................................................ 912 mac-address-table static (for Multicast MAC Address)...........
ip mroute..................................................................................................................................................................945 ip multicast-limit.......................................................................................................................................................946 ip multicast-routing................................................................................................................................................
track ipv6 route metric threshold.............................................................................................................................. 981 track ipv6 route reachability..................................................................................................................................... 982 track resolution ipv6 route........................................................................................................................................
show config............................................................................................................................................................ 1022 show ip ospf........................................................................................................................................................... 1022 show ip ospf asbr....................................................................................................................................................
router-id..................................................................................................................................................................1075 show crypto ipsec policy.........................................................................................................................................1076 show crypto ipsec sa ipv6.......................................................................................................................................
show ip pim summary...............................................................................................................................................1118 show ip pim tib......................................................................................................................................................... 1119 show running-config pim..........................................................................................................................................
class-map................................................................................................................................................................1159 clear qos statistics...................................................................................................................................................1160 description...........................................................................................................................................................
45 Routing Information Protocol (RIP).......................................................................... 1199 auto-summary............................................................................................................................................................... 1199 clear ip rip.....................................................................................................................................................................1200 debug ip rip........................
bridge-priority...............................................................................................................................................................1240 debug spanning-tree rstp.............................................................................................................................................. 1241 description......................................................................................................................................................
RADIUS Commands...................................................................................................................................................... 1281 debug radius............................................................................................................................................................ 1281 ip radius source-interface........................................................................................................................................
ip ssh rekey .............................................................................................................................................................1315 ip ssh rhostsfile........................................................................................................................................................1315 ip ssh rsa-authentication (Config)...........................................................................................................................
sflow polling-interval (Interface)................................................................................................................................... 1352 sflow sample-rate (Global)............................................................................................................................................1353 sflow sample-rate (Interface).......................................................................................................................................
show logging.......................................................................................................................................................... 1394 show logging auditlog............................................................................................................................................. 1396 show logging driverlog stack-unit...........................................................................................................................
clock summer-time recurring.........................................................................................................................................1437 clock timezone..............................................................................................................................................................1439 debug ntp.............................................................................................................................................................
stack-unit stack-group..................................................................................................................................................1473 vlan-stack access......................................................................................................................................................... 1473 vlan-stack compatible..............................................................................................................................................
show vlt detail.............................................................................................................................................................. 1508 show vlt inconsistency................................................................................................................................................. 1509 show vlt mismatch...............................................................................................................................................
1 About this Guide This book provides information about the Dell Networking OS command line interface (CLI). This book also includes information about the protocols and features found in Dell Networking OS.
Information Icons This book uses the following information symbols: NOTE: The Note icon signals important operational information. CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. WARNING: The Warning icon signals information about hardware handling that could result in injury.
2 CLI Basics This chapter describes the command line interface (CLI) structure and command modes. The Dell Networking operating software commands are in a text-based interface that allows you to use the launch commands, change command modes, and configure interfaces and protocols. Accessing the Command Line When the system boots successfully, you are positioned on the command line in EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session.
In this case, the user is “admin” on vty2. Obtaining Help As soon as you are in a command mode there are several ways to access help. To obtain a list of keywords at any command mode: Type a ? at the prompt or after a keyword. There must always be a space before the ?. To obtain a list of keywords with a brief functional description: Type help at the prompt. To obtain a list of available options: Type a keyword and then type a space and a ?.
• To navigate left or right in the Dell Networking OS command line, use the left and right Arrow keys. The shortcut key combinations at the Dell Networking OS command line are as follows: Key Combination Action CNTL-A Moves the cursor to the beginning of the command line. CNTL-B Moves the cursor back one character. CNTL-D Deletes the character at the cursor. CNTL-E Moves the cursor to the end of the line. CNTL-F Moves the cursor forward one character. CNTL-I Completes a keyword.
Using the Keyword no Command To disable, delete or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you disable that command or delete it from the running configuration. In this guide, the no form of the command is described in the Syntax portion of the command description.
Enabling Software Features on Devices Using a Command Option This capability to activate software applications or components on a device using a command is supported on the S4810, S4820T, and S6000, platforms. Starting with Release 9.4(0.0), you can enable or disable specific software functionalities or applications that need to run on a device by using a command attribute in the CLI interface.
show feature Verify the status of software applications, such as VRF, that are activated and running on a device. Syntax show feature Command Modes EXEC EXEC Privilege Command History Version 9.4(0.0) Introduced on the S4810, S4820T, and S6000. Usage Information You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. The no feature vrf command is not supported on any of the platforms.
1. Verify that you are logged in to EXEC Privilege mode. 2. Enter the configure command. The prompt changes to include (conf). From this mode, you can enter INTERFACE mode by using the interface command. CONTROL-PLANE Mode To manage control-plane traffic, use CONTROL-PLANE mode. For more information, refer to Control Plane Policing (CoPP). To enter CONTROL-PLANE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the control-plane-cpuqos command.
EXEC Mode When you initially log in to the switch, by default, you are logged in to EXEC mode. This mode allows you to view settings and enter EXEC Privilege mode, which is used to configure the device. When you are in EXEC mode, the > prompt is displayed following the host name prompt, which is “Dell” by default. You can change the host name prompt using the hostname command. NOTE: Each mode prompt is preceded by the host name. EXEC Privilege Mode The enable command accesses EXEC Privilege mode.
Prompt Interface Type Dell(conf-ifgi-1/1)# Gigabit Ethernet interface then the slot/port information Dell(conf-ifte-1/1)# Ten-Gigabit Ethernet interface then slot/port information Dell(conf-iflo-0)# Loopback interface number Dell(conf-ifnu-0)# Null Interface then zero Dell(conf-ifpo-0)# Port-channel interface number Dell(conf-ifvl-0)# VLAN Interface then VLAN number (range 1–4094) Dell(conf-ifma-1/1)# Management Ethernet interface then slot/port information Dell(conf-iftu-0)# Tunnel interfa
2. Enter the protocol lldp command. The prompt changes to include (conf-lldp) or (conf-if-interface-lldp). LLDP MANAGEMENT INTERFACE Mode To enable and configure Link Layer Discovery Protocol (LLDP) on management interfaces, use LLDP MANAGEMENT INTERFACE mode. To enter LLDP MANAGEMENT INTERFACE mode: 1. Verify that you are logged in to LLDP mode. 2. Enter the management-interface command. The prompt changes to include (conf-lldp-mgmtIf).
To enter OPENFLOW INSTANCE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the openflow of-instance command then the OpenFlow ID number of the instance you want to create or configure. The prompt changes to include (conf-of-instance of-id). You can return to the CONFIGURATION mode by entering the exit command. Per-VLAN SPANNING TREE (PVST+) Plus Mode To enable and configure the Per-VLAN Spanning Tree (PVST+) protocol, use PVST+ mode.
1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol spanning-tree rstp command. The prompt changes to include (conf-rstp). You can return to CONFIGURATION mode by using the exit command. ROUTE-MAP Mode To configure a route map, use ROUTE-MAP mode. To enter ROUTE-MAP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Use the route-map map-name [permit | deny] [sequence-number] command. The prompt changes to include (config-route-map).
2. Enter the ipv6 router ospf {process-id} command. The prompt changes to include (conf-ipv6-router_ospf). You can return to CONFIGURATION mode by using the exit command. ROUTER RIP Mode To enable and configure Router Information Protocol (RIP), use ROUTER RIP mode. For more information, refer to Routing Information Protocol (RIP). To enter ROUTER RIP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the router rip command. The prompt changes to include (conf-router_rip).
3 File Management This chapter contains command line interface (CLI) commands needed to manage the configuration files as well as other file management commands. boot system Tell the system where to access the Dell Networking OS image used to boot the system. Syntax boot system {gateway ip address| stack-unit [{stack-unit-number | all] [default | primary {system {A: | B: | bmp-boot} | tftp: | | secondary]} To return to the default boot sequence, use the no boot system command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-Series switches. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. HTTP Copy via CLI Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). This feature is supported on platform. Syntax copy http://10.16.206.
copy Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). Syntax copy compressed-config source-file-url destination-file-url Parameters Enter the following location keywords and information: compressed-config file-url Enter the keyword compressed-config to copy one file, after optimizing and reducing the size of the configuration file, to another location.
To copy a file on the external FLASH enter slot0:// followed by the filename To copy a file on a TFTP server enter tftp://hostip/filepath To copy a file from an external USB drive enter usbflash://filepath Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Dell Networking OS supports copying the running-configuration to a TFTP server, an FTP server, or a remote NFS file system. For example: • copy running-config tftp: • copy running-config ftp: • copy running-config nfsmount:///filepath You can compress the running configuration by grouping all the VLANs and the physical interfaces with the same property.
delete Delete a file from the flash. After deletion, files cannot be restored. Syntax delete flash-url [no-confirm] Parameters flash-url Enter the following location and keywords: • For a file or directory on the internal Flash, enter flash:// followed by the filename or directory name. • For a file or directory on the NFS mounted file system, enter nfsmount:// followed by the mount point and the file path.
• For a file or directory on the internal Flash, enter flash:// then the filename or directory name. • For a file or directory on an NFS mounted file system, enter nfsmount:// followed by the mount point and file path. NOTE: While displaying a file directory on a remote NFS file system, it is mandatory to specify the mount-point that indicates the working directory on the NFS file system. You cannot display details corresponding to the root directory of the remote NFS file system.
format (S-Series) Erase all existing files and reformat the filesystem in the internal flash memory. After the filesystem is formatted, files cannot be restored. Syntax format {flash: | usbflash:} Defaults None Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Introduced on S4810 and Z9000. 8.3.19.0 Introduced on S4820T.
mount nfs Mounts an NFS file system to a device. Syntax mount nfs rhost:path mount-point [username password] Parameters Enter the following location keywords and information: rhost:path Enter the remote hosts’s path directory. mount-point Enter the folder name in the local file system. username (OPTIONAL) Enter the user name to access the device. password (OPTIONAL) Enter the password. Command Modes CONFIGURATION Command History This guide is platform-specific.
upgrade system Upgrade the Dell Networking OS image. To upgrade the bootflash or bootselector image, use the upgrade boot command. Syntax Parameters upgrade system {flash: | ftp: | nfsmount: | scp: | stack-unit {stack-unit-id | all} system Enter the keyword system to upgrade the operating system (OS) image.
Example Dell# upgrade system tftp://10.11.8.12/dv-rainier-13 a: 00:39:32 : Discarded 1 pkts. Expected block num : 51. Received block num: 50 !00:39:36 : Discarded 1 pkts. Expected block num : 65. Received block num: 64 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! 93924044 bytes successfully copied System image upgrade completed successfully.
rename Rename a file in the local file system. Syntax Parameters rename url url url Enter the following keywords and a filename: • For a file on the internal Flash, enter flash:// followed by the filename. • For a file on an NFS mounted file system, enter nfsmount:// followed by the mount point and file path. • For a file on an external USB drive, enter usbflash:// followed by the filename. Command Modes EXEC Privilege Command History This guide is platform-specific.
clear-all Enter the keywords clear-all to reset the NvRAM, boot environment variables, and the system startup configuration. nvram Enter the keyword nvram to reset the NvRAM only. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Each boot path variable (primary_boot, secondary_boot, and default_boot) is further split into the following three independent variables: • primary_server, primary_file, and primary_type • secondary_server, secondary_file, and secondary_type • default_server, default_file, and default_type NOTE: For information on the default values that these variables take, refer to the Restoring Factory Default Environment Variables section in the Dell Networking OS Configuration guide.
Power-cycling the unit(s). Dell# Example (NvRAM, single unit) Dell#restore factory-defaults stack-unit 1nvram ************************************************************** * Warning - Restoring factory defaults will delete the existing * * persistent settings (stacking, fanout, etc.) * * After restoration the unit(s) will be powercycled immediately.
Example Dell#show boot system stack-unit 1 Current system image information in the system: ============================================= Type Boot Type A B ---------------------------------------------------------------Stack-unit 1 FLASH BOOT 9-0(2-1) 9-0(2-0)[boot] Dell# show bootvar Display the variable settings for the boot parameters. Syntax show bootvar Command Modes EXEC Privilege Command History This guide is platform-specific.
show file-systems Display information about the file systems on the system. Syntax show file-systems Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.
Related Commands format flash (S-Series) – Erases all the existing files and reformats the filesystem in the internal flash memory on the S-Series. show os-version Display the release and software image version information of the image file specified. Syntax Parameters show os-version [file-url] file-url (OPTIONAL) Enter the following location keywords and information: • For a file on the internal flash, enter flash:// followed by the filename.
show running-config Display the current configuration and display changes from the default values. Syntax show running-config [entity] [configured] [status] [compressed] Parameters entity (OPTIONAL) To display that entity’s current (non-default) configuration, enter one of the following keywords: NOTE: If you did not configure anything that entity, nothing displays and the prompt returns.
isis for the current ISIS configuration line for the current line configuration lldp for the current LLDP configuration load-balance for the current port-channel load-balance configuration logging for the current logging configuration mac for the current MAC ACL configuration mac-addresstable for the current MAC configuration managementeis for the current management EIS configuration managementroute for the current Management port forwarding configuration mld for the current MLD configura
snmp for the current SNMP configuration spanning-tree for the current spanning tree configuration static for the current static route configuration status for the file status information tacacs+ for the current TACACS+ configuration tftp for the current TFTP configuration trace-group for the current trace-group configuration trace-list for the current trace-list configuration uplink-stategroup for the uplink state group configuration users for the current users configuration vlt for the
Version Description 7.4.1.0 Expanded to include the last configuration change, start-up last updated (date and time), and who made the change. 6.5.4.0 Added the status option. Example Dell# show running-config Current Configuration ... ! Version 9-0(2-0) ! Last configuration change at Thu Apr 18 10:18:39 2013 by admin ! Startup-config last updated at Thu Apr 18 10:18:40 2013 by admin ! boot system stack-unit 1 primary system: A: boot system stack-unit 1 secondary tftp://10.16.127.35/Dell-SI-9-0-2-0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on S-Series 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Expanded to include the last configuration change, start-up last updated (date and time), and who made the change.
Command Fields Example (S-Series) Version Description E-Series Original command. Lines Beginning With Description Dell Network... Name of the operating system Dell Operating... OS version number Dell Application... Software version Copyright (c)... Copyright information Build Time... Software build’s date stamp Build Path... Location of the software build files loaded on the system Dell Networking OS uptime is... Amount of time the system has been up System image...
1 52-port GE/TE/FG (SE) 52 Ten GigabitEthernet/IEEE 802.3 interface(s) Example (S6000) Dell#S6000#show version Dell Real Time Operating System Software Dell Operating System Version: 2.0 Dell Application Software Version: 9-4(0-119) Copyright (c) 1999-2014 by Dell Inc. All Rights Reserved. Build Time: Tue Mar 18 10:32:02 PDT 2014 Build Path: /work.
• To copy a file on a TFTP server, enter tftp://hostip/filepath/filename. where hostip is either an IPv4 dotted decimal address or an IPv6 URI [x:x:x:x::x] format address Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
4 Control and Monitoring This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP), and trivial file transfer protocol (TFTP). NOTE: This command replaces the enable optic-info-update interval command to update information on temperature and power monitoring in the simple network management protocol (SNMP) management information base (MIB). banner exec Configure a message that is displayed when your enter EXEC mode.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series Original Command Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character. When the user is connected to the router, if a message of the day banner is configured, it displays first. If no message of the day banner is configured, the login banner and prompt appear.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.
banner motd Set a message of the day (MOTD) banner. Syntax banner motd c line c To delete a Message of the Day banner, enter no banner motd. Parameters c Enter a delineator character to specify the limits of the text banner. The delineator is a percent character (%). line Enter a text string for your MOTD banner the message with your delineator. The delineator is a percent character (%). Defaults No banner is configured.
cam-acl Allocate content addressable memory (CAM) for IPv4 and IPv6 ACLs.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start) then reload the system. The total amount of space allowed is 16 FP Blocks. System flow requires three blocks and these blocks cannot be reallocated.
For platform-specific instructions about using this command, refer to the SDN chapter in the Dell Networking OS Configuration Guide. clear line Reset a terminal line. Syntax clear line {line-number | console 0 | vty number} Parameters line-number Enter a number for one of the 12 terminal lines on the system. The range is from 0 to 11. aux 0 Enter the keywords aux 0 to reset the auxiliary port. console 0 Enter the keywords console 0 to reset the console port.
Parameters terminal (OPTIONAL) Enter the keyword terminal to specify that you are configuring from the terminal. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. do Allows the execution of most EXEC-level commands from all CONFIGURATION levels without returning to the EXEC level.
Usage Information Example The following commands are not supported by the do command: • enable • disable • exit • config Dell(conf-if-gi-5/1)#do clear counters Clear counters on all interfaces [confirm] Dell(conf-if-gi-5/1)# Dell(conf-if-gi-5/1)#do clear logging Clear logging buffer [confirm] Dell(conf-if-gi-5/1)# Dell(conf-if-gi-5/1)#do reload System configuration has been modified.
Usage Information Version Description E-Series Original command. Users entering EXEC Privilege mode or any other configured privilege level can access configuration commands. To protect against unauthorized access, use the enable password command to configure a password for the enable command at a specific privilege level. If no privilege level is specified, the default is privilege level 15.
end Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION or ROUTER OSPF modes). Syntax Command Modes Command History end • CONFIGURATION • SPANNING TREE • MULTIPLE SPANNING TREE • LINE • INTERFACE • TRACE-LIST • VRRP • ACCESS-LIST • PREFIX-LIST • AS-PATH ACL • COMMUNITY-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific.
exec-timeout Set a time interval that the system waits for input on a line before disconnecting the session. Syntax exec-timeout minutes [seconds] To return to default settings, use the no exec-timeout command. Parameters minutes Enter the number of minutes of inactivity on the system before disconnecting the current session. The range is from 0 to 35791. The default is 10 minutes for the console line and 30 minutes for the VTY line. seconds (OPTIONAL) Enter the number of seconds.
Command History • LINE, INTERFACE • TRACE-LIST • PROTOCOL GVRP • SPANNING TREE • MULTIPLE SPANNING TREE • MAC ACCESS LIST • ACCESS-LIST • AS-PATH ACL • COMMUNITY-LIST • PREFIX-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. The hostname is used in the prompt. ip http source-interface Specify an interface as the source interface for HTTP connections. This feature is supported on platform. Syntax ip http source-interface interface To delete an interface, use theno ip http source-interface interface command.
Configuring source interface for ftp communications. ip http vrf Configures an HTTP client with a VRF that is used to connect to the HTTP server. Syntax ip http vrf {management | vrf-name} To undo the HTTP client configuration, use the ip http vrf command. Parameters management Enter the keyword management for configuring the management VRF that uses an HTTP client. vrf-name Enter the name of the VRF for configuring a nondefault that uses an HTTP client.
password Enter a string up to 40 characters as the password. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
• For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a tunnel interface, enter the keyword tunnel. Defaults The IP address on the system that is closest to the Telnet address is used in the outgoing packets. Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Usage Information Configure a password with the ip ftp password command. Related Commands ip ftp password — sets the password for FTP connections.
ip telnet server enable Enable the Telnet server on the switch. Syntax ip telnet server enable To disable the Telnet server, use the no ip telnet server enable command. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Increased number of VLANs on ExaScale to 4094 (was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information If you configure a TELNET client to use a specific VRF, then you need not explicitly specify the same VRF during the TELNET client sessions corresponding to that VRF. Example Dell(conf)#ip telnet vrf vrf1 Dell(conf)#do telnet 10.10.10.2 Dell(conf)#no ip telnet vrf vrf1 ip tftp source-interface Assign an interface’s IP address in outgoing packets for TFTP traffic.
Version Description E-Series Original command ip tftp vrf Configures an TFTP client with a VRF that is used to connect to the TFTP server. Syntax ip tftp [vrf vrf-name] To undo the TFTP client configuration, use the no ip tftp [vrf vrf-name] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is used by the TFTP client. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
console 0 Enter the keyword console 0 to configure the console port. The console option for the S-Series is <0-0>. vty number Enter the keyword vty then a number from 0 to 9 to configure a virtual terminal line for remote sessions. The system supports 10 remote sessions. end-number (OPTIONAL) Enter a number from 1 to 9 as the last virtual terminal line to configure. You can configure multiple lines at one time.
Parameters limit number-ofsessions Sets the number of concurrent sessions that any user can have on console and virtual terminal lines. The range is from 1 to 12 (10 VTY lines, one console, and one AUX line). clear-line enable Enables you to clear your existing sessions. Defaults Not configured. You can use all the available sessions. Command Modes CONFIGURATION Command History This guide is platform-specific.
When you try to create more than the permitted number of sessions, the following message appears, prompting you to close one of your existing sessions. Close any of your existing sessions to log in to the system. $ telnet 10.11.178.14 Trying 10.11.178.14... Connected to 10.11.178.14. Escape character is '^]'. Login: admin Password: Maximum concurrent sessions for the user reached. Current sessions for user admin: Line Location 2 vty 0 10.14.1.97 3 vty 1 10.14.1.97 4 vty 2 10.14.1.97 5 vty 3 10.14.1.
Usage Information Only the system and security administrators can configure login activity tracking and view the login activity details of other users. If you enable user login statistics, the system displays the last successful login details of the current user and the details of any failed login attempts by others. If you use the login statistics time-period days command to set a custom time period, the system only reports the login statistics during that interval.
To disable the MOTD banner, use the no motd-banner command. Defaults Enabled on all lines. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
• continuous: transmit echo request continuously datagram size Enter the ICMP datagram size. The range is from 36 to 15360 bytes. The default is 100. timeout Enter the interval to wait for an echo reply before timing out. The range is from 0 to 3600 seconds. The default is 2 seconds. source Enter the IPv4 or IPv6 source ip address or the source interface. For IPv6 addresses, you may enter global addresses only. Enter the IP address in A.B.C.D format.
Defaults Command Modes Command History • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.0.2.
Example (IPv4) Symbol Description Q Source quench (destination too busy). M Could not fragment. ? Unknown packet type. & Packet lifetime exceeded. Dell#ping 172.31.1.255 Type Ctrl-C to abort. Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 seconds: Reply to request 1 from 172.31.1.208 0 ms Reply to request 1 from 172.31.1.216 0 ms Reply to request 1 from 172.31.1.205 16 ms :: Reply to request 5 from 172.31.1.209 0 ms Reply to request 5 from 172.31.1.
Usage Information Version Description 9.1(0.0) Added ‘conditional’ parameter. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If there is a change in the configuration, FTOS prompts you to save the new configuration. Or you can save your running configuration with the copy running-config command.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. Messages can contain an unlimited number of lines; however, each line is limited to 255 characters. To move to the next line, use . To send the message use CTR-Z; to abort a message, use CTR-C. service timestamps To debug and log messages, add time stamps. This command adds either the uptime or the current time and date.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If you do not specify parameters and enter service timestamps, it appears as service timestamps debug uptime in the running-configuration. To view the current options set for the service timestamps command, use the show runningconfig command.
Example Dell# show alarms -- Minor Alarms -Alarm Type Duration ---------------------------------------------RPM 0 PEM A failed or rmvd 7 hr, 37 min SFM 0 PEM A failed or rmvd 7 hr, 37 min SFM 1 PEM A failed or rmvd 7 hr, 37 min SFM 2 PEM A failed or rmvd 7 hr, 37 min SFM 3 PEM A failed or rmvd 7 hr, 37 min SFM 4 PEM A failed or rmvd 7 hr, 37 min SFM 5 PEM A failed or rmvd 7 hr, 37 min SFM 6 PEM A failed or rmvd 7 hr, 37 min SFM 7 PEM A failed or rmvd 7 hr, 36 min stack-unit 1 PEM A failed or rmvd 7 hr, 36
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
console [11/20 15:47:23]: [11/20 15:47:23]: [11/20 15:47:23]: console [11/20 15:47:23]: [11/20 15:47:23]: [11/20 21:17:35]: [11/20 21:17:36]: [11/20 21:17:36]: [11/20 21:19:25]: Dell# CMD-(CLI):[no ip address]by default from console CMD-(CLI):[shutdown]by default from console CMD-(CLI):[interface gigabitethernet 1/5]by default from CMD-(CLI):[no ip address]by default from console CMD-(CLI):[shutdown]by default from console CMD-(CLI):[line console 0]by default from console CMD-(CLI):[exec-timeout 0]by defau
<0-15> option usage: 0 exit command usage:1 show command-tree command usage:9 count option usage: 3 show version command usage:1 ! Global configuration mode: aaa authentication enable command usage:1 WORD option usage: 1 default option usage: 0 enable option usage: 0 line option usage: 0 none option usage: 0 radius option usage: 1 tacacs+ option usage: 0 show cpu-traffic-stats View the CPU traffic statistics.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series 6.2.1.1 Introduced on the E-Series. Traffic statistics are sorted on a per-interface basis; the interface receiving the most traffic is displayed first. All CPU and port information is displayed unless a specific port or CPU is specified. Traffic information is displayed for router ports only; not for management interfaces.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series E-Series Original command.
Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.0 The output of the show environment fan command for the S-Series is changed to display fan speeds instead of showing the fan status as up or down. Usage Information The following example shows the output of the show environment command.
----------------------------------------------------------------------------------0 39 36 37 37 31 31 46 show inventory Display the S-Series or Z-Series switch type, components (including media), and Dell Networking Operating System (OS), including hardware identification numbers and configured protocols.
Software Protocol Configured -------------------------------------------------------------LLDP Example Dell#show inventory media Slot Port Type Media Serial Number F10Qualified -----------------------------------------------------------------------------0 0 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 1 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 2 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 3 QSFP 40GBASE-CR4-1M APF11200012UQQ Yes 0 4 QSFP 40GBASE-CR4-1M APF11200012UR1 Yes 0 5 QSFP 40GBASE-CR4-1M APF11200012UR1 Yes
Usage Information Version Description 9.8(0.0) Introduced on the S4810, S4820, S4048–ON, S3048–ON, S5000, S6000, S6000ON, and Z9500. To view the successful and failed login details of the current user in the last 30 days or the custom defined period, use the show login statistics command. To view the successful and failed login details of all users in the last 30 days or the custom defined period, use the show login statistics all command.
Unsuccessful login attempt(s) in last 11 day(s): 3 -----------------------------------------------------------------The following is sample output of the show login statistics unsuccessful-attempts command. Dell#show login statistics unsuccessful-attempts There were 3 unsuccessful login attempt(s) for user admin in last 30 day(s). The following is sample output of the show login statistics unsuccessful-attempts timeperiod days command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced this version of the command for the S-Series. Usage Information The output for show memory displays the memory usage of LP part (sysdlp) of the system. The sysdlp is an aggregate task that handles all the tasks running on the S-Series’ CPU.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added the keywords management-unit [details]. 7.6.1.0 Introduced on the S-Series.
0 sysReaper 0xbae22000 60 0 tme Dell#show processes cpu <1-99> seconds details | Dell#show processes cpu 6 10000 0.00% 0.00% 0.02% management-unit ? Number of tasks with highest CPU usage last 5 Detail CPU utilization Pipe through a command management-unit details CPUID 5sec 1min 5min -------------------------------------------------CORE 0 11.73 10.79 12.82 CORE 2 11.73 12.05 14.31 Overall 11.73 11.42 13.56 PID Runtime(ms) Invoked uSecs TTY Process Process: system PID: 0 CPU usage: 5sec 5min - 12.
0x000001ac 25750 0 sysdlp 0x0000019a 10650 0 sysd 0x000003a5 860 0 clish 0x000001ad 520 0 lacp 0x000004ba 330 0 clish 0x000000c9 1240 0 nvmgr 0x000000e0 530 0 igmp 0x00000132 420 0 vrrp 0x0000028d 410 0 ovsdbsvr 0x000000a9 200 0 arpm 0x00000253 100 0 otm 0x00000206 140 0 tnlmgr 0x00000012 1290 0 mount_mfs 0x0000024d 400 0 xstp Related Commands 2575 10000 2.78% 2.48% 3.40% 1065 10000 0.60% 1.16% 2.50% 86 10000 0.40% 0.22% 0.28% 52 10000 0.20% 0.30% 0.16% 33 10000 0.20% 0.36% 0.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.
Example (S-Series) • If no response is received within a defined period of time, the SWP timeout mechanism resubmits the message at the head of the FIFO queue. • After retrying a defined number of times, the SWP-2-NOMORETIMEOUT timeout message is generated. • In the S-Series example, a retry (Retries) value of zero indicates that the SWP mechanism reached the maximum number of retransmissions without an acknowledgement.
Usage Information show processes memory output Description Total: Total system memory available MaxUsed: Total maximum memory used ever (history indicated with time stamp) CurrentUsed: Total memory currently in use CurrentFree: Total system memory available SharedUsed: Total used shared memory SharedFree: Total free shared memory PID Process ID Process Process Name ResSize Actual resident size of the process in memory Size Process test, stack, and data size Allocs Total dynamic memor
323 frrp 5206016 241664 369238 0 369238 322 xstp 7430144 2928640 38328 0 38328 321 pim 5267456 823296 62168 0 62168 314 igmp 4960256 380928 18588 16564 18588 313 mrtm 6742016 1130496 72758 0 72758 308 l2mgr 5607424 552960 735214 380972 619266 301 l2pm 5001216 167936 1429522 1176044 286606 298 arpm 4628480 217088 71092 33128 71092 294 ospf 5468160 503808 724204 662560 78208 288 dsm 6778880 1159168 39490 16564 39490 287 rtm 5713920 602112 442280 198768 376024 284 rip 4562944 258048 528 0 528 281 lacp 4673536
Defaults Command Modes Command History none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.
Command Modes Command History stack-unit unit-id (OPTIONAL) Enter the keywords stack-unit then the stack member ID for information on that stack member. The unit ID range is from 1 to 6. stack-ports status | topology (OPTIONAL) Enter the keywords stack-ports for information about the status or topology of the stack ports. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
-- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------2 1 up AC up 7048 2 2 down UNKNOWN down 0 -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed -----------------------------------------------------------------------------------2 1 up up 7021 up 6971 2 2 up up 7021 up 7072 2 3 up up 6971 up 7021 Speed in RPM Example (S6000) Dell#show system Stack MAC : 90:b1:1c:f4:9b:79 Reload-Type : normal-reload [Next boot : no
Example (S4810) Status : not present -- Unit 5 -Unit Type Status : Member Unit : not present Dell#show system stack-unit 0 -- Unit 0 -Unit Type : Management Unit Status : online Next Boot : online Required Type : S6000 - 32-port TE/FG (SI) Current Type : S6000 - 32-port TE/FG (SI) Master priority : 0 Hardware Rev : 4.0 Num Ports : 128 Up Time : 21 min, 8 sec Dell Networking OS Version : 9-4(0-168) Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Boot Flash : 3.1.1.2 Boot Selector : 3.1.0.
Jumbo Capable POE Capable FIPS Mode Boot Flash Boot Selector Memory Size Temperature Voltage Serial Number Part Number Vendor Id Date Code Country Code Piece Part ID PPID Revision Service Tag Expr Svc Code Auto Reboot Burned In MAC No Of MACs : : : : : : : : : : : : : : : : : : : : yes no disabled Present 3.20.0.
flash: Save to local flash drive (flash://filename. A maximum of 20 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
• Example (S-Series) show log Dell#show tech-support ? page Page through output stack-unit Unit Number | Pipe through a command Dell#show tech-support stack-unit 1 ? | Pipe through a command Dell#show tech-support stack-unit 1 | ? except Show only text that does not match a pattern find Search for the first occurrence of a pattern grep Show only text that matches a pattern no-more Don't paginate output save Save output to a file Dell#show tech-support stack-unit 1 | save ? flash: Save to local f
boot system stack-unit 0 default system: A: ! redundancy auto-synchronize full redundancy disable-auto-reboot stack-unit ! redundancy disable-auto-reboot stack-unit 0 redundancy disable-auto-reboot stack-unit 1 redundancy disable-auto-reboot stack-unit 2 redundancy disable-auto-reboot stack-unit 3 redundancy disable-auto-reboot stack-unit 4 redundancy disable-auto-reboot stack-unit 5 ! hardware watchdog stack-unit 0 hardware watchdog stack-unit 1 hardware watchdog stack-unit 2 hardware watchdog stack-unit 3
telnet Connect through Telnet to a server. The Telnet client and server in Dell Networking support IPv4 and IPv6 connections. You can establish a Telnet session directly to the router or a connection can be initiated from the router. NOTE: The Telnet server and client are VRF-aware. Using the vrf parameter in this command, you can make a Telnet server or client to listen to a specific VRF. This capability enables a Telent server or client to look up the correct routing table and establish a connection.
Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Added support for source-interface for link-local IPv6 addressing. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Introduced on the E-Series ExaScale (IPv6). Increased the number of VLANs on ExaScale to 4094 (was 2094). 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S-Series. terminal length Configure the number of lines displayed on the terminal screen. Syntax Parameters Defaults Command Modes Command History terminal length screen-length screen-length Enter a number of lines. Entering zero causes the terminal to display without pausing.
traceroute View a packet’s path to a specific device. Syntax traceroute {host | ip-address | ipv6-address} Parameters host Enter the name of device. ip-address Enter the IP address of the device in dotted decimal format. ipv6-address Enter the IPv6 address, in the x:x:x:x::x format, to which you are testing connectivity. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Usage Information When you enter the traceroute command without specifying an IP address (Extended Traceroute), you are prompted for a target and source IP address, timeout (in seconds) (default is 5), a probe count (default is 3), minimum TTL (default is 1), maximum TTL (default is 30), and port number (default is 33434). To keep the default setting for those parameters, press the ENTER key. For IPv6, you are prompted for a minimum hop count (default is 1) and a maximum hop count (default is 64).
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.
Version Description 9.0.0.0 Introduced on the Z9000 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Usage Information You can configure both IPv4 and IPv6 virtual addresses simultaneously, but only one of each. Each time this command is issued, it replaces the previously configured address of the same family, IPv4 or IPv6.
Usage Information 154 Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. The write memory command saves the running-configuration to the file labeled startup-configuration.
5 802.1ag 802.1ag is available on the Dell Networking OS. ccm disable Disable continuity check message (CCM). Syntax ccm disable Enter no ccm disable to enable CCM. Defaults Disabled Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.3.1.0 Introduced on the S-Series. clear ethernet cfm traceroute-cache Delete all link trace cache entries.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. disable Disable Ethernet CFM without stopping the CFM process. Syntax disable Defaults Disabled Command Modes ETHERNET CFM Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. ethernet cfm Spawn the CFM process.
• Up-MEP: monitors the forwarding path internal to a bridge on the customer or provider edge; on Dell Networking systems, the internal forwarding path is effectively the switch fabric and forwarding engine. • Down-MEP: monitors the forwarding path external to another bridge. domain [name | level] Enter the keyword domain and then enter the domain name or domain level. ma-name name Enter the keyword ma-name and then enter the name of the maintenance association. mepid mep-id Enter an MEP ID.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. mep cross-check Enable cross-checking for a MEP. Syntax mep cross-check mep-id Parameters mep-id Enter the MEP ID. The range is from 1 to 8191. Defaults none Command Modes ECFM DOMAIN Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048–ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series.
ma-name ma-name Enter the keyword ma-name and then enter the maintenance association name. dest-mep-id Enter the MEP ID that is the target of the ping. mac-addr macaddress Enter the keyword mac-addr and then enter the MAC address that is the target of the ping. src-mep-id Enter the MEP ID that originates the ping. port interface Enter the keyword port and then enter the interface that originates the ping.
Example Version Description 8.3.1.0 Introduced on the S-Series. Dell# show ethernet cfm domain Domain Name: customer Level: 7 Total Service: 1 Services MA-Name VLAN CC-Int My_MA 200 10s Domain Name: My_Domain Level: 6 Total Service: 1 Services MA-Name VLAN CC-Int Your_MA 100 10s X-CHK Status enabled X-CHK Status enabled show ethernet cfm maintenance-points local Display configured MEPs and MIPs.
0 service1 Your_MA 4 3333 MIP UP Gi 0/5 Disabled 00:01:e8:0b:c6:36 ----------------------------------------------------MPID Domain Name Level Type Port CCM-Status MA Name VLAN Dir MAC ----------------------------------------------------0 service1 4 MIP Te 1/5/1 Disabled My_MA 3333 DOWN 00:01:e8:0b:c6:36 0 service1 Your_MA 4 3333 MIP UP Te 1/5/1 Disabled 00:01:e8:0b:c6:36 show ethernet cfm maintenance-points remote Display the MEP Database.
Receive RDI: FALSE MP Status: Active show ethernet cfm mipbd Display the MIP database. Syntax show ethernet cfm mipdb Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. Dell# show ethernet cfm statistics Domain Name: Customer Domain Level: 7 MA Name: My_MA MPID: 300 CCMs: Transmitted: LTRs: Unexpected Rcvd: LBRs: Received: Received Bad MSDU: Transmitted: 1503 RcvdSeqErrors: 0 0 0 0 0 Rcvd Out Of Order: 0 show ethernet cfm port-statistics Display CFM statistics by port.
Bad CFM Pkts 0 CFM Pkts Discarded 0 CFM Pkts forwarded 102417 TX Statistics ============= Total CFM Pkts 10303 CCM Pkts 0 LBM Pkts 0 LTM Pkts 3 LBR Pkts 0 LTR Pkts 0 show ethernet cfm traceroute-cache Display the link trace cache. Syntax show ethernet cfm traceroute-cache Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults none Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
Parameters entries Enter the number of entries the link trace cache can hold. The range is from 1 to 4095 entries. Defaults 100 entries Command Modes ETHERNET CFM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.
802.1ag Version Description 8.3.1.0 Introduced on the S-Series.
6 802.1X An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only extensible authentication protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. The Dell Networking operating software supports remote authentication dial-in service (RADIUS) and active directory environments using 802.1X Port Authentication.
interface interface Restricts the debugging information to an interface. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series. If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached.
Version Description 7.4.1.0 Introduced on the E-Series. dot1x auth-type mab-only To authenticate a device with MAC authentication bypass (MAB), only use the host MAC address. Syntax dot1x auth-type mab-only Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
dot1x authentication (Configuration) Enable dot1x globally. Enable dot1x both globally and at the interface level. Syntax dot1x authentication To disable dot1x on a globally, use the no dot1x authentication command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x authentication (Configuration) — Enables dot1x globally. dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.
If a device does not respond within 30 seconds, it is assumed that the device is not 802.1X capable. Therefore, a guest VLAN is allocated to the interface and authentication, for the device, occurs at the next reauthentication interval (dot1x reauthentication). If the host fails authentication for the designated number of times, the authenticator places the port in authentication failed VLAN (dot1x auth-fail-vlan).
Usage Information Related Commands Version Description 8.3.2.0 Added the single-host and multi-host options on the C-Series, E-Series, and S-Series. • Single-host mode authenticates only one host per authenticator port and drops all other traffic on the port. • Multi-host mode authenticates the first host to respond to an Identity Request and then permits all other traffic on the port.
dot1x max-eap-req Configure the maximum number of times an extensive authentication protocol (EAP) request is transmitted before the session times out. Syntax dot1x max-eap-req number To return to the default, use the no dot1x max-eap-req command. Parameters number Enter the number of times an EAP request is transmitted before a session timeout. The range is from 1 to 10. The default is 2. Defaults 2 Command Modes INTERFACE Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series.
Usage Information Version Description 7.4.1.0 Introduced on the E-Series. The authenticator completes authentication only when you set port-control to auto. dot1x quiet-period Set the number of seconds that the authenticator remains quiet after a failed authentication with a client. Syntax dot1x quiet-period seconds To disable quiet time, use the no dot1x quiet-time command. Parameters seconds Enter the number of seconds. The range is from 1 to 65535. The default is 60.
Parameters interval seconds (Optional) Enter the keyword interval then the interval time, in seconds, after which reauthentication is initiated. The range is from 1 to 31536000 (one year). The default is 3600 (1 hour). Defaults 3600 seconds (1 hour) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x server-timeout Configure the amount of time after which exchanges with the server time-out.
Usage Information When you configure the dot1x server-timeout value, take into account the communication medium used to communicate with an authentication server and the number of RADIUS servers configured. Ideally, the dot1x server-timeout value (in seconds) is based on the configured RADIUS-server timeout and retransmit values and calculated according to the following formula: dot1x server-timeout seconds > (radius-server retransmit seconds + 1) * radius-server timeout seconds.
dot1x tx-period Configure the intervals at which EAPOL PDUs the Authenticator PAE transmits. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Command Modes Command History • EXEC • EXEC privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.
6 7 Dell# 1 0 show dot1x interface Display the 802.1X configuration of an interface. Syntax Parameters show dot1x interface interface [mac-address mac-address] interface mac-address Defaults Command Modes Command History Enter one of the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
----------------------------Dot1x Status: Enable Port Control: AUTO Port Auth Status: AUTHORIZED(MAC-AUTH-BYPASS) Re-Authentication: Disable Untagged VLAN id: 400 Guest VLAN: Enable Guest VLAN id: 100 Auth-Fail VLAN: Disable Auth-Fail VLAN id: NONE Auth-Fail Max-Attempts: NONE Mac-Auth-Bypass: Enable Mac-Auth-Bypass Only: Enable Tx Period: 3 seconds Quiet Period: 60 seconds ReAuth Max: 2 Supplicant Timeout: 30 seconds Server Timeout: 30 seconds Re-Auth Interval: 3600 seconds Max-EAP-Req: 2 Host Mode: SINGLE
Guest VLAN: Guest VLAN id: Auth-Fail VLAN: Auth-Fail VLAN id: Auth-Fail Max-Attempts: Mac-Auth-Bypass: Mac-Auth-Bypass Only: Tx Period: Quiet Period: ReAuth Max: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Max-Supplicants: Enable 100 Disable NONE NONE Enable Enable 3 seconds 60 seconds 2 30 seconds 30 seconds 3600 seconds 2 MULTI_AUTH 128 Port status and State info for Supplicant: 00:00:00:00:00:11 Port Auth Status: Untagged VLAN id: Auth PAE State: Backend State: Dell#
7 Access Control Lists (ACL) Access control lists (ACLs) are supported by the Dell Networking OS.
Command History • CONFIGURATION-EXTENDED-ACCESS-LIST • CONFIGURATION-MAC ACCESS LIST-STANDARD • CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.
• Command History CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.3.19.
ipv6 Enter the keyword ipv6 to configure an IPv6 access class. Defaults Not configured. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the ipv4 and ipv6 parameters to the command. Introduced on the S3048-ON and S4048-ON. 9.
clear counters ip access-group Erase all counters maintained for access lists. Syntax clear counters ip access-group [access-list-name] Parameters access-list-name (OPTIONAL) Enter the name of a configured access-list, up to 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
vlan vlan-id (OPTIONAL) Enter the keyword vlan then the ID numbers of the VLANs. The range is from 1 to 4094 (you can use IDs from 1 to 4094). vrf vrf-name (OPTIONAL) Enter the keyword vrf then the ID numbers of the VRFs. The range is from 1 to 63 (you can use IDs from 1 to 63). NOTE: When you specify a single VRF, use the name of the VRF instead of the VRF ID number. Use the VRF ID numbers only when you specify a range of VRFs. Defaults Not enabled.
ip control-plane egress-filter Enable egress Layer 3 ACL lookup for IPv4 CPU traffic. Syntax ip control-plane egress-filter Defaults Not enabled. Command Modes EXEC Privilege Command History Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for the 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. show ip accounting access-lists Description “Extended IP...” Displays the name of the IP ACL. “seq 5...
in | out Command Modes Command History • For a SONET interface, enter the keyword sonet followed by the slot/ port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet followed by the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE followed by the slot/port information. Identify whether ACL is applied on the ingress or egress side. EXEC Privilege Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.
• order — Enter the keyword order to specify the QoS order of priority for the ACL entry. The range is from 0 to 254 (0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). The default is, if you do not use the keyword order, the ACLs have the lowest order by default (255). host ip-address Enter the keyword host and then enter the IP address to specify a host IP address only. no-drop Enter the keywords no-drop to match only the forwarded packets.
ip access-list standard Create a standard IP access list (IP ACL) to filter based on IP address. Syntax ip access-list standard access-list-name To delete an access list, use the no ip access-list standard access-list-name command. Parameters access-list-name Enter a string up to 140 characters long as the ACL name. Defaults All IP access lists contain an implicit “deny any,” that is, if no match occurs, the packet is dropped.
permit To permit packets from a specific source IP address to leave the switch, configure a filter. Syntax permit {source [mask]| any | host ip-address} [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {source [mask] | any | host ip-address} command. source Enter the IP address in dotted decimal format of the network from which the packet was sent.
Version Description 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry. Usage Information The order option is relevant in the context of the Policy QoS feature only.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale (IPv6). 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Defaults Not configured Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8(0.0) Added the no-drop parameter. Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.
NOTE: Also refer to the Commands Common to all ACL Types and Common IP ACL Commands sections. deny Configure a filter that drops IP packets meeting the filter criteria. Syntax deny {ip | ip-protocol-number} {source mask | any | host ip-address} {destination mask | any | host ip-address} [count [byte] | log] [dscp value] [order] [monitor] [fragments] [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous.
Usage Information Version Description 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to the Port Monitoring chapter.
port port Enter the application layer port number. Enter two port numbers if using the range logical operand. The range is from 0 to 65535. The following list includes some common TCP port numbers: • 23 = Telnet • 20 and 21 = FTP • 25 = SMTP • 169 = SNMP destination Enter the IP address of the network or host to which the packets are sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous.
Usage Information Version Description 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to the Port Monitoring chapter.
• Parameters Use the no deny udp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous. any Enter the keyword any to specify that all routes are subject to the filter.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option.
Related Commands deny — assigns a filter to deny IP traffic. deny tcp — assigns a filter to deny TCP traffic. ip access-list extended Name (or select) an extended IP access list (IP ACL) based on IP addresses or protocols. Syntax ip access-list extended access-list-name To delete an access list, use the no ip access-list extended access-list-name command. Parameters access-list-name Enter a string up to 140 characters long as the access list name.
permit To pass IP packets meeting the filter criteria, configure a filter. Syntax permit {source mask | any | host ip-address} {destination mask | any | host ip-address} [count [bytes]] [dscp value] [order] [fragments] [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source mask | any | host ip-address} {destination mask | any | host ip-address} command.
Usage Information Version Description 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry.
• urg: urgent field dscp Enter the keyword dscp to deny a packet based on the DSCP value. The range is from 0 to 63. operator (OPTIONAL) Enter one of the following logical operand: port port • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port parameter) Enter the application layer port number. Enter two port numbers if you are using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.
permit — assigns a permit filter for IP packets. permit udp — assigns a permit filter for UDP packets. permit udp To pass UDP packets meeting the filter criteria, configure a filter.
Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM. Rule# Data Mask From To 1 0000000000000000 1111110000000000 0 #Covered 1023 1024 Total Ports: 1024 Related Commands ip access-list extended — creates an extended ACL. permit — assigns a permit filter for IP packets. permit tcp — assigns a permit filter for TCP packets. resequence access-list Re-assign sequence numbers to entries of an existing access-list.
Usage Information Version Description 7.4.1.0 Introduced on the E-Series. When all sequence numbers are exhausted, this feature permits re-assigning a new sequence number to entries of an existing access-list. seq Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter.
The following list includes some common TCP port numbers: • 23 = Telnet • 20 and 21 = FTP • 25 = SMTP • 169 = SNMP destination Enter the IP address of the network or host to which the packets are sent. count (OPTIONAL) Enter the keyword count to count packets the filter processes. byte (OPTIONAL) Enter the keyword byte to count bytes the filter processes. log (OPTIONAL, E-Series only) Enter the keyword log to enter ACL matches in the log. Supported on Jumbo-enabled line cards only.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to Port Monitoring.
clear counters mac access-group Clear counters for all or a specific MAC ACL. Syntax clear counters mac access-group [mac-list-name] Parameters mac-list-name (OPTIONAL) Enter the name of a configured MAC access list. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
NOTE: 1. If the MAC ACL is applied on VLAN, none of the VLAN members should have an access list applied for that VLAN. 2. If the MAC ACL is applied on a Physical or Port Channel interface, the VLAN in which this port is associated should not have an access list applied. 3. If the MAC ACL is applied on a VLAN, then that VLAN should not belong to VLAN ACL group. 4. If the MAC ACL is applied on a VLAN ACL group, then none of the VLANs in that group should have an access list applied on it.
interface interface in | out Enter the keyword interface then the one of the following keywords and slot/ port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Identify whether ACL is applied on ingress or egress side.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | mac-source-address mac-source-address-mask} command. any Enter the keyword any to specify that all routes are subject to the filter. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask (OPTIONAL) Specify which bits in the MAC address must match.
NOTE: When you configure ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands permit — configures a MAC address filter to pass packets. seq — configures a MAC address filter with a specified sequence number. mac access-list standard To configure a standard MAC ACL, name a new or existing MAC access control list (MAC ACL) and enter MAC ACCESS LIST mode.
Example Dell(conf)#mac-access-list access-list standard TestMAC Dell(config-std-macl)#permit 00:00:00:00:00:00 00:00:00:00:ff:ff count Dell(config-std-macl)#deny any count permit To forward packets from a specific source MAC address, configure a filter. Syntax permit {any | mac-source-address [mac-source-address-mask]} [count [byte]] | [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details.
NOTE: For more information, refer to the “Flow-based Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
NOTE: For more information, also refer to the Commands Common to all ACL Types and Common MAC Access List Commands sections. deny To drop packets that match the filter criteria, configure a filter.
Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
permit To pass packets matching the criteria specified, configure a filter. Syntax permit {any | host mac-address | mac-source-address mac-source-addressmask} {any | host mac-address | mac-destination-address mac-destinationaddress-mask} [ethertype operator] [count [byte]] | [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
NOTE: For more information, refer to the Flow-based Monitoring section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
clear ip prefix-list Reset the number of times traffic mets the conditions (“hit” counters) of the configured prefix lists. Syntax clear ip prefix-list [prefix-name] Parameters prefix-name (OPTIONAL) Enter the name of the configured prefix list to clear only counters for that prefix list, up to 140 characters long. Defaults Clears “hit” counters for all prefix lists unless a prefix list is specified. Command Modes EXEC Privilege Command History This guide is platform-specific.
le max-prefix-length (OPTIONAL) Enter the keyword le and then enter the maximum prefix length, which is a number from zero (0) to 32. Defaults Not configured. Command Modes PREFIX-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command Modes PREFIX-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Example Version Description 6.1.1.0 Introduced on the E-Series. Dell(conf-nprefixl)#show config ! ip prefix-list snickers Dell(conf-nprefixl)# show ip prefix-list detail Display details of the configured prefix lists. Syntax show ip prefix-list detail [prefix-name] Parameters Command Modes Command History prefix-name • EXEC • EXEC Privilege (OPTIONAL) Enter a text string as the name of the prefix list, up to 140 characters. This guide is platform-specific.
show ip prefix-list summary Display a summary of the configured prefix lists. Syntax Parameters Command Modes Command History show ip prefix-list summary [prefix-name] prefix-name • EXEC • EXEC Privilege (OPTIONAL) Enter a text string as the name of the prefix list, up to 140 characters. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters sequence-number (OPTIONAL) Enter the route map sequence number. The range is from 1 to 65535. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.
Related Commands • If a set action occurs in the first route map entry and then the same set action occurs with a different value in a subsequent route map entry, the last set of actions overrides the previous set of actions with the same set command. • If set community additive and set as-path prepend are configure, the communities and AS numbers are prepended. set community — specifies a COMMUNITY attribute. set as-path — configures a filter to modify the AS path.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set community — specifies a COMMUNITY attribute.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. match ip address — redistributes routes that match an IP address.
Related Commands Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip next-hop — redistributes routes that match the next-hop IP address.
Related Commands Version Description 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip route-source — redistributes routes that match routes advertised by other routers.
Related Commands Version Description 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address.
Related Commands Version Description pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers. match route-type — redistributes routes that match a route type.
match route-type To match routes based on the how the route is defined, configure a filter. Syntax match route-type {external [type-1 | type-2] | internal | level-1 | level-2 | local} To delete a match, use the no match route-type {local | internal | external [type-1 | type-2] | level-1 | level-2} command. Parameters external [type-1| type-2] Enter the keyword external then either type-1 or type-2 to match only on OSPF Type 1 routes or OSPF Type 2 routes.
match metric — redistributes routes that match a specific metric. match tag — redistributes routes that match a specific tag. match tag To redistribute only routes that match a specified tag value, configure a filter. Syntax match tag tag-value To remove a match, use the no match tag command. Parameters tag-value Enter a value as the tag on which to match. The range is from zero (0) to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
route-map Enable a route map statement and configure its action and sequence number. This command also places you in ROUTE-MAP mode. Syntax route-map map-name [permit | deny] [sequence-number] To delete a route map, use the no route-map map-name [permit | deny] [sequencenumber] command. Parameters Defaults map-name Enter a text string of up to 140 characters to name the route map for easy identification. permit (OPTIONAL) Enter the keyword permit to set the route map default as permit.
Example Dell(conf)#route-map dempsey Dell(config-route-map)# Related Commands show config — displays the current configuration. set as-path To modify the AS path for border gateway protocol (BGP) routes, configure a filter. Syntax set as-path prepend as-number [... as-number] To remove an AS-Path setting, use the no set as-path {prepend as-number | tag} command. Parameters prepend as-number Enter the keyword prepend and then enter up to eight AS numbers to be inserted into the BGP path information.
To return to the default, enter no set automatic-tag. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.
no-advertise Enter the keywords no-advertise to drop all routes containing the well-known community attribute of NO_ADVERTISE. All routes with the NO_ADVERTISE (0xFFFFFF02) community attribute must not be advertised to other BGP peers. no-export Enter the keywords no-export to drop all routes containing the well-known community attribute of NO_EXPORT. All routes with the NO_EXPORT (0xFFFFFF01) community attribute must not be advertised outside a BGP confederation boundary.
Parameters backbone Enter the keyword backbone to redistribute matched routes to the OSPF backbone area (area 0.0.0.0). level-1 Enter the keyword level-1 to redistribute matched routes to IS-IS Level 1. level-1-2 Enter the keyword level-1-2 to redistribute matched routes to IS-IS Level 1 and Level 2. level-2 Enter the keyword level-2 to redistribute matched routes to IS-IS Level 2. stub-area Enter the keyword stub to redistributed matched routes to OSPF stub areas. Defaults Not configured.
Parameters value Enter a number as the LOCAL_PREF attribute value. The range is from 0 to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Implemented the keyword internal. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. If you configure the set next-hop command, its configuration takes precedence over the neighbor next-hop-self command in the ROUTER BGP mode. If you configure the set next-hop command with the interface’s IP address (either Loopback or physical), the software declares the route unreachable.
Version Description pre-6.1.1.0 Introduced on the E-Series. set tag To specify a tag for redistributed routes, configure a filter. Syntax set tag tag-value To delete a setting, use the no set tag command. Parameters tag-value Enter a number as the tag. The range is from zero (0) to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
Parameters weight Enter a number as the weight used by the route meeting the route map specification. The range is from 0 to 65535. The default is router-originated = 32768 and all other routes = 0. When there are multiple routes to the same destination, the routes with a higher weight are preferred. Defaults router-originated = 32768; all other routes = 0 Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Dell(conf-nprefixl)#show config ! ip prefix-list PL_OSPF_to_RIP seq 5 permit 1.1.1.0/24 seq 10 deny 2.1.0.0/16 ge 23 seq 25 permit 192.0.0.0 bitmask 192.0.0.
Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Example Dell#show route-map route-map firpo, permit, sequence 10 Match clauses: Set clauses: tag 34 Dell# Related Commands route-map — configures a route map. AS-Path Commands The following commands configure AS-Path ACLs. ip as-path access-list Enter AS-PATH ACL mode and configure an access control list based on the BGP AS_PATH attribute.
Related Commands match as-path — matches on routes contain a specific AS-PATH. show ip as-path-access-lists Display the all AS-PATH access lists configured on the E-Series. Syntax Command Modes Command History show ip as-path-access-lists • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. pre-Version 6.1.1.0 Introduced on the E-Series.
permit no-export Dell# deny (for Standard IP ACLs) To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}}[count [byte]] [dscp value] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command.
MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces. You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode.
Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
deny tcp (for Extended IP ACLs) Configure a filter that drops transmission control protocol (TCP) packets meeting the filter criteria.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces. Related Commands deny — assigns a filter to deny IP traffic. deny tcp — assigns a filter to deny TCP traffic.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version 9.
Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100.
deny (for Standard MAC ACLs) To drop packets with a the MAC address specified, configure a filter. Syntax deny {any | mac-source-address [mac-source-address-mask]} [count [byte]] [log [interval minutes] [threshold-in-msgs [count]][monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | mac-source-address mac-source-address-mask} command.
specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG).
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The threshold range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
permit arp (for Extended MAC ACLs) Configure a filter that forwards ARP packets meeting this criteria. This command is supported only on 12-port GE line cards with SFP optics; refer to your line card documentation for specifications.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
• Parameters Defaults Use the no permit udp {source mask | any | host ip-address} {destination mask | any | host ip-address command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands.
permit — assigns a permit filter for IP packets. permit tcp — assigns a permit filter for TCP packets. permit (for Extended IP ACLs) To pass IP packets meeting the filter criteria, configure a filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, standard and extended IPv6 ACLs, and standard and extended MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
The default frequency at which ACL logs are generated is 5 minutes. By default, flow-based monitoring is not enabled. Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
permit tcp (for Extended IP ACLs) To pass TCP packets meeting the filter criteria, configure a filter.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, Z9000, and MXL 10/40GbE Switch IO Module platforms. 9.3.0.0 Added support for logging of ACLs on the S4810, S4820T, Z9000, and MXL 10/40GbE Switch IO Module platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
the generation of ACL logs is terminated. with the seq, permit, or deny commands. You can enter a threshold in the range of 1-100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. You can enter an interval in the range of 1-10 minutes.
seq (for IP ACLs) Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — configures a filter to drop packets. permit — configures a filter to forward packets. seq (for IPv6 ACLs) Assign a sequence number to a deny or permit the filter in an IPv6 access list while creating the filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3.0.0 Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit icmp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
permit (for IPv6 ACLs) To configure a filter that matches the filter criteria, select an IPv6 protocol number, ICMP, IPv6, TCP, or UDP.
You can activate flow-based monitoring for a monitoring session by entering theflow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, Z9000, and MXL 10/40GbE Switch IO Module platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
Parameters Defaults • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no deny icmp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} command log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
deny (for IPv6 ACLs) Configure a filter that drops IPv6 packets that match the filter criteria.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
8 Access Control List (ACL) VLAN Groups and Content Addressable Memory (CAM) This chapter describes the access control list (ACL) virtual local area network (VLAN) group and content addressable memory (CAM) enhancements. member vlan Add VLAN members to an ACL VLAN group. Syntax Parameters member vlan {VLAN-range} VLAN-range Enter the member VLANs using comma-separated VLAN IDs, a range of VLAN IDs, a single VLAN ID, or a combination.
Parameters group-name Enter the name of the ACL VLAN group where you want the egress IP ACLs applied, up to 140 characters. out Enter the keyword out to apply the ACL to outgoing traffic. implicit-permit Enter the keyword implicit-permit to change the default action of the ACL from implicit-deny to implicit-permit (that is, if the traffic does not match the filters in the ACL, the traffic is permitted instead of dropped).
Vlan Members Test 1-100 - test - The following sample output is displayed when using the show acl-vlan-group group-name option. NOTE: The access list name is truncated. Dell#show acl-vlan-group TestGroupSeventeenTwenty Group Name Egress IP Acl Ingress IP Acl Acl Vlan Members Test test 1-100 Ingress IPV6 The following sample output shows the line-by-line style display when using the show acl-vlan-group detail option.
Example Field Description VlanOpenFlow Number of FP blocks for VLAN open flow operations. VlanIscsi Number of FP blocks for VLAN internet small computer system interface (iSCSI) counters. VlanHp Number of FP blocks for VLAN high performance processes. VlanFcoe Number of FP blocks for VLAN Fiber Channel over Ethernet (FCoE) operations. VlanAclOpt Number of FP blocks for ACL VLAN optimzation feature.
Usage Information The VLAN ContentAware Processor (VCAP) application is a pre-ingress CAP that modifies the VLAN settings before packets are forwarded. To support the ACL CAM optimization functionality, the CAM carving feature is enhanced. A total of four VACP groups are present, of which two are for fixed groups and the other two are for dynamic groups. Out of the total of two dynamic groups, you can allocate zero, one, or two flow processor (FP) blocks to iSCSI Counters, OpenFlow and ACL Optimization.
Example 1: Output of Dell#show cam-usage | Total CAM | Used CAM |Available the show cam-usage Linecard|Portpipe| CAM Partition CAM Command ========|========|=================|=============|=============| ============== 1 | 0 | IN-L2 ACL | 1008 | 320 | 688 | | IN-L2 FIB | 32768 | 1132 | 31636 | | IN-L3 ACL | 12288 | 2 | 12286 | | IN-L3 FIB | 262141 | 14 | 262127 | | IN-L3-SysFlow | 2878 | 45 | 2833 | | IN-L3-TrcList | 1024 | 0 | 1024 | | IN-L3-McastFib | 9215 | 0 | 9215 | | IN-L3-Qos | 8192 | 0 | 8192 | | IN
16384 11 8189 196606 2878 1024 9215 8192 1024 Example 4: Output of the show camusage switch Command | 1 | IN-L3 ACL | 8192 | 3 | | | IN-L3 FIB | 196607 | 1 | | | IN-L3-SysFlow | 2878 | 0 | | | IN-L3-TrcList | 1024 | 0 | | | IN-L3-McastFib | 9215 | 0 | | | IN-L3-Qos | 8192 | 0 | | | IN-L3-PBR | 1024 | 0 | | | OUT-L3 ACL | 16384 | 0 | 16384 Dell#show cam-usage switch Linecard|Portpipe| CAM Partition | Total CAM | Used CAM |Available CAM ========|====
Examples The following sample output shows the line-by-line style display when using the show running-config acl-vlan-group option. Note that no group or access list names are truncated Dell#show running-config acl-vlan-group ! acl-vlan-group Test member vlan 1-100 ip access-group test in Dell#show running-config acl-vlan-group ! acl-vlan-group Test member vlan 1-100 ip access-group test in Test acl-vlan-group Create an ACL VLAN group.
show acl-vlan-group detail Display all the ACL VLAN Groups or display a specific ACL VLAN Group by name. To display the names in their entirety, the output displays in a line-by-line format. Syntax Parameters show acl-vlan-group detail detail Display information in a line-by-line format to display the names in their entirety. Without the detail option, the output is displayed in a table style and information may be truncated.
Usage Information 320 Enter a description for each ACL VLAN group that you create for effective and streamlined administrative and logging purposes.
9 Bidirectional Forwarding Detection (BFD) Bidirectional forwarding detection (BFD) is a detection protocol that provides fast forwarding path failure detection.
ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Introduced BFD for VRRP and OSPFv3 on Z9000, S4810, and S4820T. 9.0.
Re-enable BFD using the no bfd disable command. Defaults BFD is disabled by default. Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.2) Introduced on S4810. 9.0.0.0 Introduced on the Z9000. 8.3.19.
Version Description 7.4.1.0 Introduced on the E-Series. bfd enable (Interface) Enable BFD on an interface. Syntax bfd enable Defaults BFD is enabled on all interfaces when you enable BFD from CONFIGURATION mode. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
multiplier value Enter the keywords multiplier to specify the number of packets that must be missed in order to declare a session down. The range is from 3 to 50. The default is 3. role [active | passive] Enter the role that the local system assumes: • Active — The active system initiates the BFD session. Both systems can be active for the same session. • Passive — The passive system does not initiate a session. It only responds to a request for session initialization from the active system.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.
ip route bfd Enable BFD for all neighbors configured through static routes. Syntax ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] To disable BFD for all neighbors configured through static routes, use the no ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] command. Parameters interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval.
ipv6 ospf bfd all-neighbors Establish BFD sessions with all OSPFv3 neighbors on a single interface or use non-default BFD session parameters. Syntax ipv6 ospf bfd all-neighbors [disable | [interval interval min_rx min_rx multiplier value role {active | passive}]] To disable all BFD sessions on an OSPFv3 interface implicitly, use the no ipv6 ospf bfd allneighbors disable command in interface mode.. Parameters disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface.
To disable BFD on a specific interface while you configure BFD in CONFIGURATION mode, use the keyword disable. isis bfd all-neighbors Enable BFD on all IS-IS neighbors discovered on an interface.
Usage Information Version Description 8.3.12.0 Introduced on S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the E-Series. This command provides the flexibility to fine-tune the timer values based on individual interface needs when ISIS BFD is configured in CONFIGURATION mode. Any timer values specified with this command overrides timers set using the bfd all-neighbors command.
Usage Information When you enable a BFD session with a specified BGP neighbor or peer group using the bfd neighbor command, the default BFD session parameters are used (interval: 100 milliseconds, min_rx: 100 milliseconds, multiplier: 3 packets, and role: active) if you have not specified parameters with the bfd neighbor command.
Usage Information When you explicitly disable a BGP neighbor for a BFD session with the neighbor bfd disable command: • The neighbor does not inherit the global BFD disable values configured with the bfd neighbor command or configured for the peer group to which the neighbor belongs. • The neighbor only inherits the global timer values configured with the bfd neighbor command: interval, min_rx, and multiplier.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Added support for BFD for BGP on the S4810. 8.4.1.3 Added support for BFD for BGP on the E-Series ExaScale. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.5.1.0 Added support for BFD for VLAN and port-channel interfaces on the E-Series. 7.4.1.0 Introduced BFD on physical ports on the E-Series.
vrrp bfd neighbor Establish a BFD for VRRP session with a neighbor. Syntax vrrp bfd neighbor ip-address To remove the BFD session with the neighbor, use the no vrrp bfd neighbor ip-address command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format (A.B.C.D). Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
10 Border Gateway Protocol BGP is an external gateway protocol that transmits interdomain routing information within and between autonomous systems (AS). BGP version 4 (BGPv4) supports classless inter-domain routing (CIDR) and the aggregation of routes and AS paths. Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically sent messages to update those routing tables.
NOTE: Use this attribute to start a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a nondefault VRF. ipv6 unicast Enter the keyword ipv6 followed by the keyword unicast to enable BGPv6 mode. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install the IPv6 route in that VRF. NOTE: It will not be possible to enable VRF mode for IPv6 unicast without configuring the corresponding IPv4 unicast mode for the same VRF.
AS_SET includes AS_PATH and community information from the routes included in the aggregated route. Defaults Command Modes Command History attribute-map mapname (OPTIONAL) Enter the keywords attribute-map then the name of a configured route map to modify attributes of the aggregate, excluding AS_PATH and NEXT_HOP attributes. summary-only (OPTIONAL) Enter the keyword summary-only to advertise only the aggregate address. Specific routes are not advertised.
When an aggregate address is denied using a peer's outbound route-map, individual routes suppressed by the aggregate address are advertised to that peer. The attribute-map corresponding to an aggregate address is applied during the outbound update creation time; hence the value set in that attribute-map will not be shown in the output of the show ip bgp aggregate route command.
bgp always-compare-med Allows you to enable comparison of the MULTI_EXIT_DISC (MED) attributes in the paths from different external ASs. Syntax bgp always-compare-med To disable comparison of MED, enter no bgp always-compare-med. Defaults Disabled (that is, the software only compares MEDs from neighbors within the same AS). Command Modes ROUTER BGP Command History This guide is platform-specific.
Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced the dynamic application of AS notation changes. 8.2.1.0 Introduced. Before enabling this feature, enable the enable bgp four-octet-as-supportcommand.
Defaults Disabled (that is, the software considers the AS_PATH when choosing a route as best). Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.
(but equal-length) autonomous system paths. Without this option, ECMP expects the AS paths to be identical for load-sharing. bgp bestpath med confed Enable MULTI_EXIT_DISC (MED) attribute comparison on paths learned from BGP confederations. Syntax bgp bestpath med confed To disable MED comparison on BGP confederation paths, enter the no bgp bestpath med confed command. Defaults Disabled Command Modes ROUTER BGP Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 6.3.1.
bgp client-to-client reflection Allows you to enable route reflection between clients in a cluster. Syntax bgp client-to-client reflection To disable client-to-client reflection, use the no bgp client-to-client reflection command. Defaults Enabled when a route reflector is configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
...as-number (OPTIONAL) Enter up to 16 confederation numbers. The range is from 0 to 65535 (2 byte), from 1 to 4294967295 (4 byte), or from 0.1 to 65535.65535 (dotted format). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.4.(0.0) Introduced on the S4810. bgp dampening Enable BGP route dampening and configure the dampening parameters.
Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enter the bgp dampening command, the default values for half-life, reuse, suppress, and max-suppress-time are applied.
Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information All routers apply the bgp default local-preference command setting within the AS. To set the local preference for a specific route, use the set local-preference command in ROUTE-MAP mode. Related Commands set local-preference — assigns a local preference value for a specific route. bgp dmzlink-bw Enables BGP Link Bandwidth.
To turn off the default, use the no bgp enforce-first-as command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Routers supporting 4-byte ASNs advertise that function in the OPEN message. The behavior of a 4-byte router is slightly different depending on whether it is speaking to a 2-byte router or a 4-byte router. When creating Confederations, all the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. This feature is advertised to BGP neighbors through a capability advertisement. In Receiver Only mode, BGP saves the advertised routes of peers that support this capability when they restart. BGP graceful restart is active only when the neighbor becomes established. Otherwise it is disabled.
When you change the path selection from Deterministic to Non-Deterministic, the path selection for the existing paths remains Deterministic until you enter the clear ip bgp command to clear existing paths. bgp recursive-bgp-next-hop Enable next-hop resolution through other routes learned by BGP. Syntax bgp recursive-bgp-next-hop To disable next-hop resolution, use the no bgp recursive-bgp-next-hop command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific.
Defaults Enabled Command Modes ROUTER BGP (conf-router_bgp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
bgp router-id Assign a user-given ID to a BGP router. Syntax bgp router-id ip-address To delete a user-assigned IP address, use the no bgp router-id command. Parameters ip-address Enter an IP address in dotted decimal format to reset only that BGP neighbor. Defaults The router ID is the highest IP address of the Loopback interface or, if no Loopback interfaces are configured, the highest IP address of a physical interface on the router.
NOTE: Use this attribute to clear a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a a non-default VRF. * Enter an asterisk ( * ) to reset all BGP sessions. <1-4294967295> Enter <1-4294967295> to clear peers with the AS number. <0.1-65535.65535> Enter <0.1-65535.65535> to clear peers with the AS number in dot format. A.B.C.D Enter the BGP neighbor address in the A.B.C.D format to clear.
Related Commands bgp recursive-bgp-next-hop — disables next-hop resolution through other routes learned by the BGP. clear ip bgp dampening Clear information on route dampening and return the suppressed route to the Active state.
The clear ip bgp dampening command does not clear the history paths. clear ip bgp flap-statistics Clear BGP flap statistics, which includes number of flaps and the time of the last flap.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
in Enter the keyword in to re-configure soft inbound updates. out Enter the keyword out to re-configure soft outbound updates. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.
To disable all BGP debugging, use the no debug ip bgp command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to debug BGP information corresponding to that VRF. NOTE: Use this attribute to debug BGP protocol operations corresponding to either a default or non-default VRF. A.B.C.D Enter the IPv4 address of the neighbor in dotted decimal format. X:X:X:X::X (OPTIONAL) Enter an IPv6 address.
Usage Information To view information on both incoming and outgoing routes, do not include the in and out parameters in the debugging command. The in and out parameters cancel each other; for example, if you enter the debug ip bgp in command and then enter the debug ip bgp out command, you do not see information on the incoming routes. Entering a no debug ip bgp command removes all configured debug commands for BGP. Related Commands debug ip bgp events — views information about BGP events.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.6.1.0 Introduced IPv6 MGBP support for the E-Series. debug ip bgp events Display information on local BGP state changes and other BGP events. Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] events [in | out] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.
Usage Information To remove all configured debug commands for BGP, enter the no debug ip bgp command. debug ip bgp keepalives Display information about BGP keepalive messages. Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] keepalives [in | out] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] keepalives [in | out] command.
debug ip bgp notifications Allows you to view information about BGP notifications received from neighbors. Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] notifications [in | out] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] notifications [in | out] command.
debug ip bgp soft-reconfiguration Enable soft-reconfiguration debug. Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group-name] softreconfiguration To disable, use the debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peergroup-name] soft-reconfiguration command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable soft-reconfiguration debugging on that VRF. A.B.C.
To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] updates [in | out | prefix-list prefix-listname] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view BGP updates information corresponding to that VRF. A.B.C.D (OPTIONAL) Enter an IPv4 address of the neighbor. X:X:X:X::X (OPTIONAL) Enter an IPv6 address.
default-metric Allows you to change the metric of redistributed routes to locally originated routes. Use this command with the redistribute command. Syntax default-metric number To return to the default setting, use the no default-metric command. Parameters number Enter a number as the metric to be assigned to routes from other protocols. The range is from 1 to 4294967295. Defaults 0 Command Modes ROUTER BGP Command History This guide is platform-specific.
Parameters description Enter a description to identify the BGP protocol (80 characters maximum). Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.
Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Support from 2 to 64 paths on the S4810. Command syntax changed to maxpath (was maximum-paths). 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. By default, when you create a neighbor/peer group configuration in the Router BGP context, this enables IPv4/Unicast AFI/SAFI. When you use activate in the new context, the neighbor/peer group enables for AFI/SAFI. It is not possible to de-activate a peer from the IPv4 unicast address family.
neighbor advertisement-interval Set the advertisement interval between BGP neighbors or within a BGP peer group. Syntax neighbor {ip-address | peer-group-name} advertisement-interval seconds To return to the default value, use the no neighbor {ip-address | peer-group-name} advertisement-interval command. Parameters Defaults ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format.
Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. seconds Enter a number as the time interval, in seconds, before BGP route updates are sent. The range is from 0 to 3600 seconds. Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information You cannot set this configuration for a peer that is associated with a peer group. Similarly, you cannot associate a peer to a peer group if that peer is already configured with these settings.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you apply a route map to a BGP peer or neighbor with the neighbor default-originate command configured, the software does not apply the set filters in the route map to that BGP peer or neighbor.
Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. neighbor distribute-list Distribute BGP information via an established prefix list.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information Other BGP filtering commands include: neighbor filter-list, ip as-path access-list, and neighbor route-map. Related Commands neighbor route-map — assigns a route map to a neighbor or peer group. neighbor ebgp-multihop Attempt and accept BGP connections to external peers on networks that are not directly connected.
neighbor fall-over Enable or disable fast fall-over for BGP neighbors. Syntax neighbor {ipv4-address | peer-group-name} fall-over To disable, use the no neighbor {ipv4-address | peer-group-name} fall-over command. Parameters ipv4-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group. Defaults Disabled. Command Modes ROUTER BGP Command History This guide is platform-specific.
Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the advertisement interval for all routers in the peer group. as-number Enter the AS number to reset all neighbors belonging to that AS. The range is from 0 to 65535 (2 byte), from 1 to 4294967295 (4 byte) or from 0.1 to 65535.65535 (dotted format). no prepend Specifies that local AS values do not prepend to announcements from the neighbor.
peer-group-name Enter the name of the peer group. maximum Enter a number as the maximum number of prefixes allowed for this BGP router. The range is from 1 to 4294967295. threshold (OPTIONAL) Enter a number to be used as a percentage of the maximum value. When the number of prefixes reaches this percentage of the maximum value, the E-Series software sends a message. The range is from 1 to 100 percent. The default is 75.
To delete a password, use the no neighbor {ip-address | peer-group-name} password command. Parameters ip-address Enter the IP address of the router to be included in the peer group. peer-group-name Enter the name of a configured peer group. encryption-type (OPTIONAL) Enter 7 as the encryption type for the password entered. 7 means that the password is encrypted and hidden. password Enter a text string up to 80 characters long. The first character of the password must be a letter.
If you configure a password on one neighbor, but you have not configured a password for the neighboring router, the following message appears on the console while the routers attempt to establish a BGP session between them: %RPM0-P:RP1 %KERN-6-INT: No BGP MD5 from [peer's IP address] :179 to [local router's IP address]:65524 Also, if you configure different passwords on the two routers, the following message appears on the console: %RPM0-P:RP1 %KERN-6-INT: BGP MD5 password mismatch from [peer's IP address]
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. You can assign up to 256 peers to one peer group. When you add a peer to a peer group, it inherits all the peer group’s configured parameters.
Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information When you create a peer group, it is disabled (Shut mode). Related Commands neighbor peer-group (assigning peers) — assigns routers to a peer group.
Usage Information Version Description 8.3.8.0 Introduced the limit keyword on the S4810. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. After you configure a peer group as passive, assign it a subnet using the neighbor softreconfiguration inbound command. For passive eBGP limits, the Remote AS must be different from the AS for this neighbor.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added 4-byte support. To accept 4-byte formats before entering a 4 byte AS Number, configure your system. If the number parameter is the same as the AS number used in the router bgp command, the remote AS entry in the neighbor is considered an internal BGP peer entry. This command creates a peer and the newly created peer is disabled (Shutdown).
Usage Information Applies to EBGP neighbors only. Configure your system to accept 4-byte formats before entering a 4 byte AS Number. If the AS-PATH contains both public and private AS number or contains AS numbers of an EBGP neighbor, the private AS numbers are not removed. If a confederation contains private AS numbers in its AS-PATH, the software removes the private AS numbers only if they follow the confederation numbers in the AS path. Private AS numbers are from 64512 to 65535 (2 byte).
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When you apply a route map to outbound routes, only routes that match at least one section of the route map are permitted. If you identify a peer group by name, the peers in that peer group inherit the characteristics in the Route map used in this command.
Usage Information A route reflector reflects routes to the neighbors assigned to the cluster. Neighbors in the cluster do not need not to be fully meshed. By default, when you use no route reflector, the internal BGP (IBGP) speakers in the network must be fully meshed. The first time you enter this command, the router configures as a route reflector and the specified BGP neighbors configure as clients in the route-reflector cluster.
Usage Information This command enables sender-side-loopdetect for a specified BGP neighbor. BGP does not advertise a route to a peer if the AS-Path of the route already contains the peer's AS. NOTE: If you configure a neighbor to accept such routes using the neighbor allowas-in command, you must disable sender-side loop detection for that neighbor. Related Commands bgp client-to-client reflection — enables route reflection between the route reflector and the clients.
In order that settings corresponding to the neighbor send-community command take effect, you must execute the clear ip bgp command immediately after you execute the neighbor sendcommunity command. If you do not set any of the optional parameters (standard or extended), then both standard as well as extended attributes are sent. If you set either the standard or extended parameter, only the attribute that is specified is sent. neighbor shutdown Disable a BGP neighbor or peer group.
show ip bgp neighbors — displays the current BGP neighbors. neighbor soft-reconfiguration inbound Enable soft-reconfiguration for BGP. Syntax neighbor {ip-address | peer-group-name} soft-reconfiguration inbound To disable, use the no neighbor {ip-address | peer-group-name} softreconfiguration inbound command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to disable or enable all routers within the peer group.
Related Commands show ip bgp neighbors — displays routes received by a neighbor. neighbor timers Set keepalive and hold time timers for a BGP neighbor or a peer group. Syntax neighbor {ip-address | peer-group-name} timers keepalive holdtime To return to the default values, use the no neighbor {ip-address | peer-group-name} timers command. Parameters Defaults ip-address Enter the IP address of the peer router in dotted decimal format.
• the lower of the holdtime value is the new holdtime value, and • whichever is the lower value; one-third of the new holdtime value, or the configured keepalive value, is the new keepalive value. neighbor update-source Enable the E-Series software to use Loopback interfaces for TCP connections for BGP sessions. Syntax neighbor {ip-address | peer-group-name} update-source interface To use the closest interface, use the no neighbor {ip-address | peer-group-name} update-source interface command.
neighbor weight Assign a weight to the neighbor connection, which is used to determine the best path. Syntax neighbor {ip-address | peer-group-name} weight weight To remove a weight value, use the no neighbor {ip-address | peer-group-name} weight command. Parameters ip-address Enter the IP address of the peer router in dotted decimal format. peer-group-name Enter the name of the peer group to disable all routers within the peer group. weight Enter a number as the weight.
network Specify the networks for the BGP process and enter them in the BGP routing table. Syntax network ip-address mask [route-map map-name] To remove a network, use the no network ip-address mask [route-map map-name] command. Parameters ip-address Enter an IP address in dotted decimal format of the network. mask Enter the mask of the IP address in the slash prefix length format (for example, / 24). The mask appears in command outputs in dotted decimal format (A.B.C.D).
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Dell Networking OS software resolves the network address the network command configures with the routes in the main routing table to ensure that the networks are reachable using non-BGP routes and nondefault routes. As BGP does not query next-hop information corresponding to locally originated routes, a local route with an unreachable next-hop is chosen as the best route.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Although Dell Networking OS does not generate a route due to the backdoor config, there is an option for injecting/sourcing a local route in the presence of network backdoor config on a learned route.
route-map mapname (OPTIONAL) Enter the keyword route-map then the name of an established route map. Only the following ROUTE-MAP mode commands are supported: • match ip address • set community • set local-preference • set metric • set next-hop • set origin • set weight If the route map is not configured, the default is deny (to drop all routes). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
When a combination of locally originated and peer originated routes occurs, both these routes will exist in the RTM. However, only the best route is kept active in the RTM and the remaining route is rendered inactive. It is possible to keep only one locally originated route in the BGP database. Network command has preference over the re-distributed routes. When the locally originated route is no longer present in the database the other route is automatically installed.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. You can use the redistribute command to advertise the IGP cost as the MED on redistributed routes. When you set the route-map with metric-type internal and apply outbound to an EBGP peer/peer-group, the advertised routes corresponding to those peer/peer-groups have the IGP cost set as MED.
Example Dell(conf)#router bgp 3 Dell(conf-router_bgp)# set extcommunity bandwidth Enables you to set extended community bandwidth. Syntax set extcommunity bandwidth To disable extended community bandwidth, enter the no set extcommunity bandwidth command. Parameters bandwidth Defaults N/A Command Modes ROUTER MAP Command History Usage Information Enter the keyword bandwidth to enable extended community bandwidth. The range is from 0 to 102400. Version Description 9.8(0.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Dell(conf-router_bgp)#show capture bgp-pdu neighbor 20.20.20.2 Incoming packet capture enabled for BGP neighbor 20.20.20.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Dell(conf-router_bgp)#show config ! router bgp 100 network 1.1.11.1/32 network 1.1.12.1/32 network 1.1.13.1/32 neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown show ip bgp View the current BGP IPv4 routing table for the system.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the add-path option to the S4810. Output on the S4810 shows the ADDPATH parameters. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When you enable the bgp non-deterministic-med command, the show ip bgp command output for a BGP route does not list the INACTIVE reason.
Origin IGP, Metric 0, LocalPref Extended Communities : DMZ-Link Bw: 2000 kbytes* Related Commands 100, Weight 0, internal show ip bgp community — views the BGP communities. neighbor maximum-prefix — controls the number of network prefixes received. show ip bgp cluster-list View BGP neighbors in a specific cluster.
Usage Information Example The following describes the show ip bgp cluster-list command shown in the following example. Field Description Network Displays the destination network prefix of each BGP route. Next Hop Displays the next hop address of the BGP router. If 0.0.0.0 is listed in this column, then local routes exist in the routing table. Metric Displays the BGP route’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight.
ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. community-number Enter the community number in AA:NN format where AA is the AS number (2 bytes) and NN is a value specific to that autonomous system.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. To view the total number of COMMUNITY attributes found, use the show ip bgp summary command. The text line above the route table states the number of COMMUNITY attributes found. The show ip bgp community command without any parameters lists BGP routes with at least one BGP community attribute and the output is the same as for the show ip bgp command output.
show ip bgp community-list View routes that a specific community list affects. Syntax show ip bgp [vrf vrf-name] [ipv4 {unicast | multicast} | ipv6 unicast] community-list community-list-name [exact-match] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes affected by a specific community list corresponding to that VRF.
Example Field Description Network Displays the destination network prefix of each BGP route. Next Hop Displays the next hop address of the BGP router. If 0.0.0.0 is listed in this column, then local routes exist in the routing table. Metric Displays the BGP route’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight. Path Lists all the ASs the route passed through to reach the destination network.
ipv6 unicast Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
Origin codes: i - IGP, e - EGP, ? - incomplete Network d 55.0.0.0/24 From 172.16.0.2 Reuse Path 00:36:23 200 Dell# show ip bgp detail Display BGP internal information for the IPv4 Unicast address family. Syntax show ip bgp [ipv4 unicast] detail Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
0x41a19d04 : NdUpdAFMsk 0 : AFRstSet 0x41a1a298 : NHopDfrdHdP 0x41a1a3e0 : NumNhDfrd 0 : CfgHdrAFMsk 1 AFChkNetTmrP 0x41ee705c : AFRtDamp 0 : AlwysCmpMed 0 : LocrHld 10 : LocrRem 10 : softReconfig 0x41a1a58c DefMet 0 : AutoSumm 1 : NhopsP 0x41a0d100 : Starts 0 : Stops 0 : Opens 0 Closes 0 : Fails 0 : Fatals 0 : ConnExps 0 : HldExps 0 : KeepExps 0 RxOpens 0 : RxKeeps 0 : RxUpds 0 : RxNotifs 0 : TxUpds 0 : TxNotifs 0 BadEvts 0 : SynFails 0 : RxeCodeP 0x41a1b6b8 : RxHdrCodeP 0x41a1b6d4 : RxOpCodeP 0x41a1b6e4 R
show ip bgp extcommunity-list View information on all routes with Extended Community attributes. Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] extcommunity-list [list name] vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view information on all routes with extended community attributes corresponding to that VRF.
Example Dell#show run extcommunity-list ! ip extcommunity-list ecl1 permit rt 100:4 permit soo 40:4 Dell#show ip bgp extcommunity-list ecl1 BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.5 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network Next Hop Metric *> 55.0.0.
Usage Information Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp filter-list hello command shown in the following example.
show ip bgp flap-statistics View flap statistics on BGP routes. Syntax show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] flap-statistics [ip-address [mask]] [filter-list as-path-name] [regexp regular-expression] Parameters vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view flap statistics on BGP routes corresponding to that VRF.
The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view routes corresponding to the VRF that contain inconsistent originating AS numbers. ipv4 unicast (OPTIONAL) Enter the keywords ipv4 unicast to view information only related to ipv4 unicast routes. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
* * * *> 4.0.0.0/8 * * * * 6.0.0.0/20 * *> * * 9.2.0.0/16 * --More-- 63.114.8.34 63.114.8.33 63.114.8.33 63.114.8.60 63.114.8.34 63.114.8.33 63.114.8.33 63.114.8.60 63.114.8.34 63.114.8.33 63.114.8.33 63.114.8.60 63.114.8.
ip-address (OPTIONAL) Enter the IP address of the neighbor to view only BGP information exchanged with that neighbor. advertised-routes (OPTIONAL) Enter the keywords advertised-routes to view only the routes the neighbor sent. dampened-routes (OPTIONAL) Enter the keywords dampened-routes to view information on dampened routes from the BGP neighbor. detail (OPTIONAL) Enter the keyword detail to view neighbor-specific internal information for the IPv4 Unicast address family.
Usage Information Version Description 6.3.10 The output is changed to display the total number of advertised prefixes. After a peer reset, the contents of the notification log messages is displayed in hex values for debugging. The neighbor information that this command displays does not include counts corresponding to ignored prefixes and updates. However, the martian case is an exception where neighbor information corresponding to ignored updates is displayed.
Example The Lines Beginning with: Description Prefix advertised Displays the number of network prefixes advertised, the number rejected, and the number withdrawn from the BGP routing table. Connections established Displays the number of TCP connections established and dropped between the two peers to exchange BGP information. Last reset Displays the amount of time since the peering session was last reset. Also states if the peer resets the peering session.
show ip bgp next-hop View all next hops (using learned routes only) with current reachability and flap status. This command only displays one path, even if the next hop is reachable by multiple paths. Syntax Command Modes Command History show ip bgp [vrf vrf-name] next-hop • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf to view all path attributes in the BGP database corresponding to that VRF. NOTE: DescriptionYou can use this attribute to view information on all path attributes in the BGP database that correspond to either a default or a nondefault VRF. regexp regularexpression Enter a regular expression then use one or a combination of the following characters to match: • . = (period) any single character (including a white space).
Example Total Displays the total number of BGP path attributes. Address Displays the internal address where the path attribute is stored. Hash Displays the hash bucket where the path attribute is stored. Refcount Displays the number of BGP routes using this path attribute. Metric Displays the MED attribute for this path attribute. Path Displays the AS path for the route, with the origin code for the route listed last. Numbers listed between braces {} are AS_SET information.
Usage Information Example The following describes the show ip bgp paths community command shown in the following example. Field Description Address Displays the internal address where the path attribute is stored. Hash Displays the hash bucket where the path attribute is stored. Refcount Displays the number of BGP routes using these communities. Community Displays the community attributes in this BGP path.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the add-path option to the S4810.
neighbor peer-group (creating group) — creates a peer group. show ip bgp regexp Display the subset of the BGP routing tables matching the regular expressions specified. Syntax show ip bgp [vrf vrf-name] regexp regular-expression [character] Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to view the subset of BGP routing tables that match the regular expression specified on that VRF.
Usage Information Example Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp regexp command shown in the following example. Field Description Network Displays the destination network prefix of each BGP route. Next Hop Displays the next hop address of the BGP router. If 0.0.0.0 is listed in this column, then non-BGP routes exist in the router’s routing table.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.
Field Description BGP community entries Displays the number of BGP COMMUNITY attributes processed and the amount of memory used to process them. The show ip bgp community command provides more details on the COMMUNITY attributes. Dampening enabled Displayed only when you enable dampening. Displays the number of paths designated as history, dampened, or penalized. Neighbor Displays the BGP neighbor address. AS Displays the AS number of the neighbor.
Down State/Pfx 172.16.0.2 200 00:05:34 2 192.168.10.2 100 00:00:00 (shut) Dell# 10 8 0 0 0 0 22 0 0 0 show running-config bgp To display the current BGP configuration, use this feature. Syntax show running-config bgp Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters keepalive Enter a number for the time interval, in seconds, between keepalive messages sent to the neighbor routers. The range is from 1 to 65535. The default is 60 seconds. holdtime Enter a number for the time interval, in seconds, between the last keepalive message and declaring the router dead. The range is from 3 to 65535. The default is 180 seconds. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
To disable debugging, use the no debug ip bgp dampening command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 multicast routes.
Defaults • external-distance = 20 • internal-distance = 200 • local-distance = 200 Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Version 7.8.1.0 Introduced on the S-Series.
Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
BGP Extended Communities (RFC 4360) BGP Extended Communities, as defined in RFC 4360, is an optional transitive BGP attribute. BGP Extended Communities provides two major advantages over Standard Communities: • The range is extended from 4-octet (AA:NN) to 8-octet (Type:Value) to provide enough number communities. • Communities are structured using a new “Type” field (1 or 2-octets), allowing you to provide granular control/filter routing information based on the type of extended communities.
Related Commands • If the rt option comes after soo, without the additive option, rt overrides the communities soo sets. • If the rt with the additive option comes after soo, rt adds the communities soo sets. set extcommunity soo — sets the extended community site-of-origin in the route-map. set extcommunity soo To set extended community site-of-origin in Route Map, use this feature.
show ip bgp paths extcommunity To display all BGP paths having extended community attributes, use this feature. Syntax Command Modes Command History show ip bgp paths extcommunity • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version 9.0.2.
Parameters Command Modes Command History word • EXEC • EXEC Privilege Enter the name of the extended community list you want to view. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Version 7.8.1.
peer-group name Clear and reapply policies for all BGP routers in the specified peer group. ipv6 unicast Clear and reapply policies for all IPv6 unicast routes. in Reapply only inbound policies. NOTE: If you enter soft, without an in or out option, both inbound and outbound policies are reset. out Reapply only outbound policies. NOTE: If you enter soft, without an in or out option, both inbound and outbound policies are reset.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.4.1.0 Added support for IPv4 multicast and IPv6 unicast routes. 7.8.1.0 Introduced on the S4810. 7.7.1.
neighbor soft-reconfiguration inbound Enable a BGP soft-reconfiguration and start storing updates for inbound IPv6 unicast routes. Syntax Parameters neighbor {ipv4-address | ipv6-address | peer-group-name} softreconfiguration inbound ipv4-address | ipv6address Enter the IP address of the neighbor for which you want to start storing inbound routing updates. peer-group-name Enter the name of the peer group for which you want to start storing inbound routing updates. Defaults Disabled.
summary Display a summary of RPF routes. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant FTOS Command Line Reference Guide. The following is a list of the FTOS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.0.0 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. ipv6 prefix-list — configures an IPv6 prefix-list.
11 Content Addressable Memory (CAM) Content addressable memory (CAM) commands are supported on the Dell Networking platform. NOTE: Not all CAM commands are supported on all platforms. Be sure to note the platform when looking for a command. WARNING: If you are using these features for the first time, contact Dell Networking Technical Assistance Center (TAC) for guidance. CAM Profile Commands The CAM profiling feature allows you to partition the CAM to best suit your application.
number] ecfmacl number [nlbclusteracl number] ipv4pbr number }openflow number | fcoe number} [iscsioptacl number] [vrfv4acl number] Parameters 450 default Use the default CAM profile settings and set the CAM as follows: • L2Acl : 6 • IPV4Acl : 4 • IPV6Acl : 0 • IPV4Qos : 2 • L2Qos : 1 • L2PT : 0 • IpMacAcl : 0 • VmanQos : 0 • VmanDualQos : 0 • EcfmAcl : 0 • nlbclusteracl: 0 • FcoeAcl : 0 • iscsiOptAcl : 0 • ipv4pbr : 0 • vrfv4Acl :0 • Openflow : 0 • fedgovacl : 0 l2acl n
NOTE: When you reconfigure CAM allocation, use the nlbclusteracl number command to change the number of NLB ARP entries. The range is from 0 to 2. The default value is 0. At the default value of 0, eight NLB ARP entries are available for use. This platform supports up to 512 CAM entries. Select 1 to configure 256 entries. Select 2 to configure 512 entries.
Usage Information Version Description 9.2(0.2) Added support for fcoe. 9.1.(0.0) Added support for OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.2 Clarified block information for the S4810. 8.3.10.0 Introduced on the S4810. 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. cam-optimization Optimize CAM utilization for QoS Entries by minimizing require policy-map CAM space. Syntax Parameters cam-optimization [qos] qos Optimize CAM usage for QoS. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
nlbclusteracl: 0 -- stack-unit 3 -Current Settings(in block sizes) 1 block = 256 entries L2Acl : 2 Ipv4Acl : 4 Ipv6Acl : 4 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr : 0 vrfv4Acl : 0 Openflow : 0 fedgovacl : 0 nlbclusteracl: 0 test cam-usage Verify that enough CAM space is available for the IPv6 ACLs you have created.
QoS Optimization for IPv6 ACLs does not impact the CAM usage for applying a policy on a single (or the first of several) interfaces. It is most useful when a policy is applied across multiple interfaces; it can reduce the impact to CAM usage acr subsequent interfaces. The following describes the test cam-usage command shown in the following example. Term Explanation Stack-Unit Lists the stack unit or units that are checked. Entering all shows the status for all stacks.
Stack-Unit|Portpipe|CAM Partition|Available CAM|EstimatedCAM per Port|Status -------------------------------------------------------------------------1| 0| IPv4Flow| 102| 0|Allowed Dell# Content Addressable Memory (CAM) 457
12 Control Plane Policing (CoPP) The CoPP commands are supported on the Dell Networking platform. control-plane-cpuqos To manage control-plane traffic, enter control-plane mode and configure the switch. Syntax control-plane-cpuqos Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes CONTROL-PLANE-CPUQOS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. This command applies the service-policy based on the type of protocol defined in the ACL rules. Create ACL and QoS policies prior to enabling this command. For CoPP, use the keyword cpu-qos when creating qos-policy-input. Related Commands ip access-list extended — creates an extended IP ACL.
Usage Information Use this command to add the IPv4 catch-all route (0.0.0.0/0) in the LPM route forwarding table if it was deleted using the no ip unknown-unicast command previously. This will be the default configuration after reload. ipv6 unknown-unicast Disable soft forwarding of unknown IPv6 destination packets. Syntax [no] ipv6 unknown-unicast Defaults Soft forwarding is enabled. Command Modes CONFIGURATION Command History Usage Information Version Description 9.8(0.
Usage Information Version Description 8.3.8.0 Introduced on the S4810. This command applies the service-policy based on the type of protocol defined in the ACL rules. Create ACL and QoS policies prior to enabling this command.
UDP (DHCP) UDP (DHCP-R) TCP (FTP) ICMP IGMP TCP (MSDP) UDP (NTP) OSPF PIM UDP (RIP) TCP (SSH) TCP (TELNET) VRRP Dell# Dell# Dell# Dell# Dell# 67/68 67 any any any any/639 any any any any any any any 68/67 67 21 any any 639/any 123 any any 520 22 23 any _ _ _ _ _ _ _ _ _ _ _ _ _ Q10 Q10 Q6 Q6 Q11 Q11 Q6 Q9 Q11 Q9 Q6 Q6 Q10 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ show ipv6 protocol-queue-mapping Display the queue mapping for each configured IPv6 protocol.
Dell# Dell# show mac protocol-queue-mapping Display the queue mapping for the MAC protocols. Syntax show mac protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.
13 Debugging and Diagnostics The basic debugging and diagnostic commands are supported by the Dell Networking Operating System. This chapter contains the following sections: • Diagnostic and Monitoring Commands • Offline Diagnostic Commands • Hardware Commands Diagnostics and Monitoring Commands The following section describes the diagnostics and monitoring commands. For similar commands, refer to the Control and Monitoring chapter. logging coredump stack-unit Enable coredump on a stack.
reachable, the application coredump is aborted. Dell Networking OS completes the coredump process and wait until the upload is complete before rebooting the system. Offline Diagnostic Commands The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, Dell Networking OS results are saved as a text file (TestReport-SU-X.txt) in the flash directory. This show file command is available only on master and standby.
verbose Enter the keyword verbose to run the diagnostic in Verbose mode. Verbose mode gives more information in the output than Standard mode. testname Enter the keyword testname to run a specific test case. Enclose the test case name in double quotes (“ “). For example: diag stack-unit 1 level1 testname “first”. You can use this option only for interactive tests. no-reboot Enter the keyword no-reboot to prevent the system from rebooting after the test.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added a warning message to the off-line diagnostic. 7.7.1.0 Introduced on the S-Series. You cannot enter this command on a Master or Standby unit. The system reboots when the off-line diagnostics complete. This reboot is an automatic process.
The system reboots when the off-line diagnostics complete. This reboot is an automatic process. A warning message appears when the offline stack-unit command is implemented. Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags. Proceed with Offline-Diags [confirm yes/no]:y Hardware Commands These commands display information from a hardware sub-component or ASIC. clear hardware stack-unit Clear statistics from selected hardware components.
Related Commands Version Description 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. show hardware stack-unit — displays the data plane or management plane input and output statistics of the designated component of the designated stack member. clear hardware system-flow Clear system-flow statistics from selected hardware components.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command.
port-set 0–0 Enter the keywords port-set with a port-pipe number. . The range is from 0 to 0. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Version Description 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. show hardware stack-unit Display the data plane or management plane input and output statistics of the designated component of the designated stack member.
TI monitor Defaults Enter the unit keyword to show information regarding the TI register. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (DataPlane) Version Description 9.8(0.0) Replaced the keyword port with interface.
0 errors Dell# Example (Drops Unit) Dell#sh hard stack-unit 1 drops unit 0 PortNumberIngress Drops IngMac Drops Total Mmu Drops 1 0 0 0 2 0 0 0 3 0 0 0 4 0 0 0 EgMac Drops Egress Drops 0 0 0 0 0 0 0 0 Dell# Example (PortStats) Dell#show hardware stack-unit 1 unit 0 ena/ speed/ link auto STP port link duplex scan neg? state pause ge0 down SW Yes Block ge1 !ena SW Yes Block ge2 !ena SW Yes Block ge3 !ena SW Yes Block ge4 !ena SW Yes Forward ge5 !ena SW Yes Forward ge6 !ena SW Yes Forward ge7 !ena SW Yes Fo
0x0060d04c ASFPORTSPEED.ge13 = 0x00000000 0x0060e04c ASFPORTSPEED.ge14 = 0x00000000 0x0060f04c ASFPORTSPEED.ge15 = 0x00000000 0x0061004c ASFPORTSPEED.ge16 = 0x00000000 0x0061104c ASFPORTSPEED.ge17 = 0x00000000 0x0061204c ASFPORTSPEED.ge18 = 0x00000000 0x0061304c ASFPORTSPEED.ge19 = 0x00000000 0x0061404c ASFPORTSPEED.ge20 = 0x00000000 0x0061504c ASFPORTSPEED.ge21 = 0x00000000 0x0061604c ASFPORTSPEED.ge22 = 0x00000000 0x0061704c ASFPORTSPEED.ge23 = 0x00000005 0x0061804c ASFPORTSPEED.
RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - 64 Byte Frame Counter 65 to 127 Byte Frame Counter 128 to 255 Byte Frame Counter 256 to 511 Byte Frame Counter 512 to 1023 Byte Frame Counter 1024 to 1518 Byte Frame Counter 1519 to 1522 Byte Good VLAN Frame Counter 1519 to 2047 Byte Frame Counter 2048 to 4095 Byte Frame Counter 4096 to 9216 Byte Fra
TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - PFC Frame Priority PFC Frame Priority PFC Frame Priority PFC Frame Priority PFC Frame Priority PFC Frame Priority PFC Frame Priority Debug Counter 0 Debug Counter 1 Debug Counter 2 Debug Counter 3 Debug Counter 4 Debug Counter 5 Debug Counter 6 Debug Counter 7 Debug Counter 8 Debug Counter 9 Debug Counter 10 Debug Counter 11 1 2 3 4 5 6 7 --------------------unit: 0 port: 61 (interface Gi 1/60) Description RX RX RX RX RX RX RX RX RX RX RX RX RX
RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX Example (Details) - Debug Counter 1 Debug Counter 2 Debug Counter 3 Debug Counter 4 Debug Counter 5 Debug Counter 6 Debug Counter 7 Debug Counter 8 64 Byte Frame Counter 65 to 127 Byte Frame Counter 128 to 255 Byte Frame Counter 256 to 511 Byte Frame Counter 512 to 1023 Byte Frame Counter 1024 to 1518 Byte Frame Counter 1519 to 1522 Byte Good VLAN Fram
The Current Link Status Is Front End Link Status 0x000000000000400000000000 Front End Port Present Status 0x000000000000000000000000 Back Plane Link Status 0x00000000 ****************************************************** Link Status of all the ports in the Device - 1 The linkStatus of Front End Port 0 is FALSE The linkStatus of Front End Port 1 is FALSE The linkStatus of Front End Port 2 is FALSE The linkStatus of Front End Port 3 is FALSE The linkStatus of Front End Port 4 is FALSE The linkStatus of Front
Default Packet Buffer allocate for the Queue: Used Packet Buffer: 0 ----- Buffer Stats for Interface Gi 1/5 Queue Maximum Shared Limit: 7667 Default Packet Buffer allocate for the Queue: Used Packet Buffer: 0 ----- Buffer Stats for Interface Gi 1/6 Queue
----- Buffer stats for unit: 0 port: 1 (interface Gi 1/1) ---------------------------------------------------------------------------PG# PRIORITIES ALLOTED (CELLS) COUNTER (CELLS) MIN SHARED MODE HDRM MIN SHARED HDRM -----------------------------------------------------------------------0 61440 0 STATIC 174 0 0 0 Dell# Example displaying queue range Dell#show hardware buffer interface gigabitethernet 1/1 queue all bufferinfo ----- Buffer Stats for Interface Gi 1/1 Queue 0 ----Maximum Shared Limit: 29514 De
show hardware counters interface Display the counter information for a specific interface. Syntax Parameters Defaults Command Modes Command History show hardware counters interface interface counters Enter the keywords counters to display counter value for the specified stackmember the port-pipe. interface interface Enter any of the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
RX - Jabber Frame Counter RX - VLAN Tag Frame Counter RX - Double VLAN Tag Frame Counter RX - RUNT Frame Counter RX - Fragment Counter RX - VLAN Tagged Packets RX - Ingress Dropped Packet RX - MTU Check Error Frame Counter RX - PFC Frame Priority 0 RX - PFC Frame Priority 1 RX - PFC Frame Priority 2 RX - PFC Frame Priority 3 RX - PFC Frame Priority 4 RX - PFC Frame Priority 5 RX - PFC Frame Priority 6 RX - PFC Frame Priority 7 RX - Debug Counter 0 RX - Debug Counter 1 RX - Debug Counter 2
snapshot for both unicast and multicast packets for the specific interface Example displaying egress queue-level snapshot for unicast packets for the specific interface Example displaying egress queue-level snapshot for multicast packets for the specific interface Example displaying ingress prioritygroup level snapshot for the specific interface show hardware stack-unit buffer-stats-snapshot (Total Buffer Information) View the buffer statistics tracking resource information depending on the type of buffer
Command History Usage Information Version Description 9.8(0.0) Added the keyword interface all. Introduced on the S4048–ON and S3048– ON. 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Introduced on the S5000. 9.3(0.0) Introduced on the S6000, S4810, and S4820T.
MCAST 3 0 Unit 1 unit: 3 port: 29 (interface Fo 1/172) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 33 (interface Fo 1/176) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 37 (interface Fo 1/180) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------- show hardware sys
Version Description 7.8.1.0 Introduced on the S-Series. Example Dell#show hardware system-flow layer2 stack-unit 1 port-set 0 counters ----------------------------------------------------------EntryId Description #HITS ----------------------------------------------------------2048 STP BPDU Redirects 0 2047 LLDP BPDU Redirects 0 2045 LACP traffic Redirects 0 2044 GVRP traffic Redirects 0 2043 ARP Reply Redirects 0 2042 802.
action={act=CosQCpuNew, param0=7(0x07), param1=0(0x00)}, action={act=CopyToCpu, param0=0(0x00), param1=0(0x00)}, action={act=UpdateCounter, param0=1(0x01), param1=0(0x00)}, meter=NULL, counter={idx=3, mode=0x01, entries=1} ################# FP Entry for redirecting ARP Replies to RSM ############# EID 2043: gid=1, slice=15, slice_idx=0x04, prio=0x7fb, flags=0x82, Installed tcam: color_indep=0, higig=0, higig_mask=0, KEY=0x00000000 00000000 00000000 00000000 00000000 00000806 00001600 , FPF4=0x00 MASK=0x0000
RX - Unicast Packet Counter RX - 64 Byte Frame Counter RX - 65 to 127 Byte Frame Counter RX - 128 to 255 Byte Frame Counter RX - 256 to 511 Byte Frame Counter RX - 512 to 1023 Byte Frame Counter RX - 1024 to 1518 Byte Frame Counter RX - 1519 to 1522 Byte Good VLAN Frame Counter RX - 1519 to 2047 Byte Frame Counter RX - 2048 to 4095 Byte Frame Counter RX - 4096 to 9216 Byte Frame Counter RX - Good Packet Counter RX - Packet/Frame Counter RX - Unicast Frame Counter RX - Multicast Frame Counter RX - Broadcast
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command. Example Dell#show hardware vlan-counters 1 Counters for vlanid: 1 -----------------------Total number of inpackets: 0 Total number of inbytes: 0 Total number of outpackets: 0 Total number of outbytes: 0 Dell# Related Commands clear hardware system-flow — clears the statistics from selected hardware components. show hardware drops Displays internal drops on the specified interface or for a range of interface.
Version Description 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.4 Added user port information. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
14 Dynamic Host Configuration Protocol (DHCP) Dynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses and other configuration parameters to network end-stations (hosts) based on the configuration policies the network administrators determine. The Dell Networking operating system supports the basic DHCP commands on this platform.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Entering after the clear ip dhcp binding command clears all the IPs from the binding table. debug ip dhcp server Display FTOS debugging messages for DHCP. Syntax debug ip dhcp server [events | packets] Parameters events Enter the keyword events to display the DHCP state changes.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command-Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. default-router Assign a default gateway to clients based on the address pool.
Command Modes CONFIGURATION DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
domain-name Assign a domain to clients based on the address pool. Syntax Parameters domain-name name name Give a name to the group of addresses in a pool. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. hardware-address For manual configurations, specify the client hardware address. Syntax hardware-address address Parameters address Enter the hardware address of the client.
Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.2.1.0 Introduced on the C-Series and S-Series. netbios-name-server Specify the NetBIOS Windows Internet Naming Service (WINS) name servers, in order of preference, that are available to Microsoft Dynamic Host Configuration Protocol (DHCP) clients. Syntax netbios-name-server address [address2...address8] Parameters address Enter the address of the NETBIOS name server. You may enter up to eight, in order of preference.
Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
pool Create an address pool. Syntax pool name Parameters name Enter the address pool’s identifying name. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp configuration Display the DHCP configuration. Syntax Parameters show ip dhcp configuration [global | pool name] pool name Display the configuration for a DHCP pool. global Display the DHCP configuration for the entire system. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Commands to Configure Secure DHCP DHCP, as defined by RFC 2131, provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks. arp inspection Enable dynamic arp inspection (DAI) on a VLAN. Syntax arp inspection Defaults Disabled Command Modes INTERFACE VLAN Command History This guide is platform-specific.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series. arp inspection — enables dynamic ARP inspection on a VLAN. clear ip dhcp snooping Clear the DHCP binding table.
Example Version Description 9.6(0.0) Added the keywords discard-counters, interface, and the variable interface on the S4810, S4820T, S5000, S6000, Z9000, Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series.
ip dhcp relay Enable Option 82. Syntax ip dhcp relay information-option [remote-id | trust-downstream] Parameters remote-id Configure the system to enable the remote-id string in option-82. trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 9.2.(0.0) Introduced on the S4810 and S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series on Layer 2 interfaces. 7.8.1.0 Introduced on the C-Series and S-Series on Layer 3 interfaces. When enabled, no learning takes place until you enable snooping on a VLAN.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command-Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping binding Create a static entry in the DHCP binding table.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the E-Series. 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. IPv6 DHCP Snooping Binding Create a static DHCP snooping binding entry in the snooping database.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping database Delay writing the binding table for a specified time. Syntax ip dhcp snooping database write-delay minutes Parameters minutes The range is from 5 to 21600. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping database renew Renew the binding table.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping trust Configure an interface as trusted.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp source-address-validation Enable the IP Source Guard. Syntax Parameters [no] ip dhcp source-address-validation [ipmac] [vlan vlan-id] ipmac Enable IP+MAC Source Address Validation.
ip dhcp relay information-option Enable Option 82. Syntax ip dhcp relay information-option [trust-downstream] [vpn] Parameters trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. vpn Enter the keyword vpn to add VPN/VRF related sub-option to relay agent information Option 82. NOTE: Adds the VPN/VRF related sub-options into the relay agent information option(82). When DHCP broadcasts are forwarded by the relay agent from clients to DHCP server.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
ip-address Enter an IP address through which the host address can be reached. Default Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. Version 9.4.(0.0) Introduced on the S-Series and Z-Series.
show ip dhcp snooping Display the contents of the DHCP binding table or display the interfaces configured with IP Source Guard. Syntax Parameters show ip dhcp snooping [binding | source-address-validation [discardcounters [interface interface]]] binding Display the binding table. source-addressvalidation Display the interfaces configured with IP Source Guard. discard-counters (OPTIONAL) Display the number of dropped packets.
Example The following example displays the interfaces configured with IP Source Guard: Dell> show ip dhcp snooping source-address-validation ip sav access-list on GigabitEthernet 1/1 Total cam count 3 permit host 0.0.0.0 count (0 packets) permit host 10.1.1.252 count (0 packets) permit host 10.1.1.253 count (0 packets) ipmac-vlan sav access-list on GigabitEthernet 1/2 Total cam count 4 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 10.1.1.
deny access-list on Port-channel 10 on stack-unit 2 Total cam count 1 deny vlan 10 count (0 packets) deny access-list on Port-channel 10 on stack-unit 3 Total cam count 1 deny vlan 10 count (0 packets) NOTE: The output for port-channel interfaces does not display the physical interface. If the LAG member interfaces belong to different stack-units, the counters are displayed per stack-unit for that port channel. show ipv6 dhcp snooping Display the DHCPv6 snooping binding database.
Commands to Configure DNS To configure the Domain Names Systems (DNS) on the system, use the following commands: ip name-server Configures the name server IP addresses for VRF. Using this command, you can configure up to a maximum of six IP addresses per VRF. Syntax ip name-server [vrf vrf-name] ip-address [ip-address2] [ip-address3] [ipaddress4] [ip-address5] [ip-address6] To undo the name server ip address configuration for VRF, use the no ip name-server [vrf vrfname] ip-address command.
To undo the domain name configuration corresponding to a specific VRF, use the no ip domain-name [vrf vrf-name] name command. Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to configure the domain corresponding to that VRF. name Enter the name of the domain to be appended to the in complete DNS requests corresponding to the specified VRF. Defaults None Command Modes EXEC Command History This guide is platform-specific.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information Use this command to add domain names to the DNS lists corresponding to a specific VRF. You can add up to a maximum of six domain names to the DNS list corresponding to a VRF. This domain is used to complete the unqualified host names. Example Dell(conf)#ip domain-list Dell(conf)#ip domain-list vrf jay dell.
clear host Removes one or all dynamically learned host table entries for a specific VRF. Syntax Parameters clear host [vrf vrf-name] {* | host-name} vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to delete dynamically learned host table entries corresponding to that VRF. host-name Enter the name of the host corresponding to which you want to delete the dynamically learnt host table entries. * Enter * to delete all host table entries.
15 Equal Cost Multi-Path (ECMP) Equal cost multi-path (ECMP) is supported on the Dell Networking OS. ecmp-group Provides a mechanism to monitor traffic distribution on an ECMP link bundle. A system log is generated when the standard deviation of traffic distribution on a member link exceeds a defined threshold. Syntax ecmp-group {ecmp-group-id interface interface | link-bundle-monitor} To remove the selected interface, use the ecmp-group no interface command.
Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. Using CONFIGURATION mode, create an ECMP group ID. You can then assign interfaces to the ECMP group using CONFIGURATION ECMP-GROUP mode. You can also enable on the port-channel configuration using the CONFIGURATION ECMP-GROUP command mode. hash-algorithm Changes the hash algorithm used to distribute traffic flows across a Port Channel.
hg {crc16 | crc16cc | crc32MSB | crc32LSB | xor1 | xor2 | xor4 | xor8 | xor16} stack-unit stack-unit-number | port-set port-pipe • xor4: Use CRC16_BISYNC_AND_XOR4 — Upper 8 bits of CRC16-BISYNC and lower 8 bits of xor4 • xor8: Use CRC16_BISYNC_AND_XOR8 — Upper 8 bits of CRC16-BISYNC and lower 8 bits of xor8 • xor16: Use CR16 — 16 bit XOR Z-Series only: Enter the keyword hg then one of the following options: • crc16: Use CRC16_BISYNC — 16 bit CRC16-bisync polynomial (default) • crc16cc: Use CRC16_C
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
When a Port Channel member leaves or is added to the Port Channel, the hash algorithm is recalculated to balance traffic across the members. hash-algorithm ecmp Change the hash algorithm used to distribute traffic flows across an ECMP (equal-cost multipath routing) group. Term heading Description heading Syntax hash-algorithm ecmp {crc-upper} | {dest-ip} | {lsb} To return to the default hash algorithm, use the no hash-algorithm ecmp command.
Term heading Description heading When a member leaves or is added to the ECMP group, the hash algorithm is recalculated to balance traffic across the members. hash-algorithm seed Select the seed value for the ECMP, LAG, and NH hashing algorithm. Syntax Parameters hash-algorithm seed value [stack-unitslot/port] [port-set number] seed value Enter the keyword seed then the seed value. The range is from 0 to 2,147,483,646. stack–unit slot/port Enter the keyword stack-unit then the slot/port number.
NOTE: While the seed is stored separately on each port-pipe, the same seed is used across all CAMs. You cannot separate LAG and ECMP but you can use different algorithms across the chassis with the same seed. If LAG member ports span multiple port-pipes and line cards, set the seed to the same value on each port-pipe to achieve deterministic behavior. If the hash algorithm configuration is removed, the hash seed does not go to the original factory default setting.
To disable weighted ECMP calculations, enter the no ip ecmp weighted command. Defaults N/A Command Modes CONFIGURATION Command History Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S-Series. Enabling this CLI would inform the FIB to re-program the destination prefix paths with weights in the HW/CAM on the fly. If disabled, the CLI would inform the FIB to re-program the destination prefix paths with no weights or regular ECMP.
Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. link-bundle-distribution trigger-threshold Provides a mechanism to set the threshold to trigger when traffic distribution begins being monitored on an ECMP link bundle. Syntax link-bundle-distribution trigger-threshold [percent] To exit from ecmp group mode, use the exit command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
16 FIPS Cryptography To configure federal information processing standards (FIPS) cryptography, use the following commands: fips mode enable Enable the FIPS cryptography mode on the platform. Syntax [no] fips mode enable To disable the FIPS cryptography mode, use the no fips mode enable command.
Example Dell#show fips status FIPS Mode : Disabled Dell# Dell#show fips status FIPS Mode : Enabled Dell# Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1(0.0) Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.
Hostbased Authentication : disabled. RSA Authentication : disabled. Vty Encryption HMAC Remote IP With FIPS Mode enabled: Dell#show ip ssh SSH server : enabled. SSH server version : v2. SSH server vrf : default. SSH server ciphers : 3des-cbc,aes128-cbc,aes192-cbc,aes256cbc,aes128-ctr,aes192-ctr,aes256-ctr. SSH server macs : hmac-sha1-96. SSH server kex algorithms : diffie-hellman-group14-sha1. Password Authentication : enabled. Hostbased Authentication : disabled. RSA Authentication : disabled.
FIPS mode is enabled or disabled: • 3des-cbc: Force ssh to use 3des-cbc encryption cipher. • aes128–cbc: Force ssh to use the aes128–cbc encryption cipher. • aes192–cbc: Force ssh to use the aes256–cbc encryption cipher. • aes256–cbc: Force ssh to use the aes128–cbc encryption cipher. • aes128–ctr: Force ssh to use the aes256–cbc encryption cipher. • aes192–ctr: Force ssh to use the aes128–cbc encryption cipher. • aes256–cbc: Force ssh to use the aes256–cbc encryption cipher.
Related Commands Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1(0.0) Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. ip ssh server Configure an SSH server. show ip ssh clientpub-keys Display the client-public keys. Dell Networking OS supports both inbound and outbound SSH sessions using IPv4 or IPv6 addressing.
hmac-sha1 hmac-sha1-96 hmac-sha2-256 hmac-sha2-256-96 Force Force Force Force ssh ssh ssh ssh to to to to use use use use hmac-sha1 HMAC algorithm hmac-sha1-96 HMAC algorithm hmac-sha2-256 HMAC algorithm hmac-sha2-256-96 HMAC algorithm FIPS Cryptography 541
17 Force10 Resilient Ring Protocol (FRRP) Force10 resilient ring protocol (FRRP) is supported on Dell Networking OS. FRRP is a proprietary protocol for that offers fast convergence in a Layer 2 network without having to run the spanning tree protocol (STP). The resilient ring protocol is an efficient protocol that transmits a high-speed token across a ring to verify the link status. All the intelligence is contained in the master node with practically no intelligence required of the transit mode.
Usage Information Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
Defaults Disabled. Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. disable Disable the resilient ring protocol. Syntax disable To enable the Resilient Ring Protocol, use the no disable command. Defaults Disabled Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific.
interface Configure the primary, secondary, and control-vlan interfaces. Syntax interface {primary interface secondary interface control-vlan vlan-id} To return to the default, use the no interface {primary interface secondary interface control-vlan vlan-id} command.
Version Description 7.4.1.0 Introduced. Usage Information This command causes the Ring Manager to take ownership of the two ports after IFM validates the configuration. Ownership is relinquished for a port only when the interface does not play a part in any control VLAN, that is, the interface does not belong to any ring. Related Commands show frrp — displays the Resilient Ring Protocol configuration information. member-vlan Specify the member VLAN identification numbers.
mode Set the Master or Transit mode of the ring. Syntax mode {master | transit} To reset the mode, use the no mode {master | transit} command. Parameters master Enter the keyword master to set the Ring node to Master mode. transit Enter the keywordtransit to set the Ring node to Transit mode. Defaults Mode None Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
timer Set the hello interval or dead interval for the Ring control packets. Syntax timer {hello-interval milliseconds}| {dead-interval milliseconds} To remove the timer, use the no timer {hello-interval [milliseconds]}| {deadinterval milliseconds} command. Parameters hello-interval milliseconds Enter the keyword hello-interval then the time, in milliseconds, to set the hello interval of the control packets.
18 GARP VLAN Registration (GVRP) The Dell Networking operating system supports the basic GVRP commands on the Dell Networking OS. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through a network quickly. A GARP participant registers or de-registers its attributes with other participants by making or withdrawing declarations of attributes.
clear gvrp statistics Clear GVRP statistics on an interface. Syntax Parameters clear gvrp statistics interface interface interface interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
To disable debugging, use the no debug gvrp {config | events | pdu} command. Parameters config Enter the keyword config to enable debugging on the GVRP configuration. event Enter the keyword event to enable debugging on the JOIN/LEAVE events. pdu Enter the keyword pdu then one of the following Interface keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Defaults As above. Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable — globally disables GVRP. gvrp registration Configure the GVRP register type.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Fixed registration prevents an interface, configured using the command line, to belong to a VLAN (static configuration) from being unconfigured when it receives a Leave message. Therefore, Registration mode on that interface is fixed. Normal registration is the default registration. The port’s membership in the VLAN depends on GVRP.
show config Display the global GVRP configuration. Syntax show config Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Usage Information If no ports are GVRP participants, the message output changes from GVRP Participants running on to GVRP Participants running on no ports.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.
19 High Availability (HA) High availability (HA) in the Dell Networking operating software is configuration synchronization to minimize recovery time in the event of a route processor module (RPM) failure. The feature is available on Dell Networking OS. In general, a protocol is defined as “hitless” in the context of an RPM failure/failover and not failures of a line card, SFM, or power module. A protocol is defined as hitless if an RPM failover has no impact on the protocol.
There is no need to reload or reboot the system when you insert the patch. The In-Service Modular patch replaces the existing process code. After installation is complete, the system executes the patch code as though it was always there. Related Commands show patch — displays the system patches loaded with the in-service modular hot fix command. process restartable Enable a process to be restarted. Restartability is subject to a maximum restart limit.
redundancy auto-failover-limit Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM failover occurs. This command does not affect user-initiated (manual) failovers. Syntax redundancy auto-failover-limit [count number [period minutes] | period minutes]] To disable the auto-failover limit control, use the no redundancy auto-failover-limit command.
redundancy disable-auto-reboot Prevent the system from auto-rebooting the failed module. Syntax redundancy disable-auto-reboot stack-unit [0–11 | members} [rpm| card number | all] To return to the default, use the no redundancy disable-auto-reboot stack-unit rpm command. Parameters rpm Enter the keyword rpm to disable auto-reboot of the failed RPM. stack-unit Enter the keyword stack-unit then the stack-unit ID number. Default Disabled (that is, the failed module is automatically rebooted).
Parameters stack-unit Enter the keyword stack-unit then the stack-unit ID number. Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. redundancy protocol Enable hitless protocols.
• show redundancy — displays the current redundancy configuration. redundancy reset-counter Reset failover counter and timestamp information displayed in the show redundancy command. Syntax redundancy reset-counter Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. When you insert or remove a secondary RPM with logical SFM, the system must add or remove the backplane links to the switch fabric trunk. To avoid traffic disruption, use this command when you insert the secondary RPM.
Parameters full Enter the keyword full to synchronize all data. Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.
show processes restartable Display the processes and tasks configured for restartability. Syntax show processes restartable [history] Parameters history Display the last time the restartable processes crashed. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Field Description • Last Data Sync Record the reason for the last RPM failover Displays the data sync information and the timestamp for the data sync: • Start-up Config is the contents of the startup-config file. • Line Card Config is the line card types configured and interfaces on those line cards. • Runtime Event Log is the contents of the Event log. • Running Config is the current running-config. This field only appears when you enter the command from the Primary RPM.
20 ICMP Message Types This chapter lists and describes the possible ICMP message type resulting from a ping. The first three columns list the possible symbol or type/code. For example, you would receive a ! or 03 as an echo reply from your ping. ICMP Messages and Their Definitions. Symbol Type Code . Query Error Timeout (no reply) ! 0 U 3 C Description 4 3 echo reply . destination unreachable: 0 network unreachable . 1 host unreachable . 2 protocol unreachable .
Symbol & Type Code Description Query 8 0 echo request . 9 0 router advertisement . 10 0 router solicitation . 11 time exceeded: 0 time-to-live equals 0 during transit . 1 time-to-live equals 0 during reassembly . 12 576 Error parameter problem: 1 IP header bad (catchall error) . 2 required option missing . 13 0 timestamp request . 14 0 timestamp reply . 15 0 information request (obsolete) . 16 0 information reply (obsolete) . 17 0 address mask request .
21 Internet Group Management Protocol (IGMP) The IGMP commands are supported by the Dell Networking operating software on the Dell Networking OS. This chapter contains the following sections: • IGMP Commands • IGMP Snooping Commands IGMP Commands Dell Networking OS supports IGMPv1/v2/v3 and is compliant with RFC-3376.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.
• For a port channel interface, enter the keywords port-channel then a number. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on E-Series. The access list accepted is an extended ACL. To block IGMP reports from hosts, on a per-interface basis based on the group address and source address that you specify in the access list, use this feature.
deletion. In addition, this command provides a way to enable immediate-leave processing for specified groups. ip igmp last-member-query-interval Change the last member query interval, which is the Max Response Time inserted into Group-Specific Queries sent in response to Leave Group messages. This interval is also the interval between Group-Specific Query messages. Syntax ip igmp last-member-query-interval milliseconds To return to the default value, use the no ip igmp last-member-query-interval command.
To return to the default values, use the no ip igmp query-interval command. Parameters seconds Enter the number of seconds between queries sent out. The range is from 1 to 18000. The default is 60 seconds. Defaults 60 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters seconds Enter the number of seconds for the maximum response time. The range is from 1 to 25. The default is 10 seconds. Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.
std-access-list Specify the standard IP access list that contains the mapping rules for multicast groups. source-address Specify the multicast source address to which the groups are mapped. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Version Description 9.7(0.0) Changed the default IGMP from version 2 to version 3. Introduced on the S6000ON 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Group Address Interface Mode Uptime Expires Last Reporter 225.0.0.0 Vlan 100 IGMPv2 00:00:05 00:02:04 3.0.0.51 Example (Details) 225.0.0.1 Vlan 100 IGMPv2 00:00:05 00:02:04 3.0.0.51 225.0.0.2 Vlan 100 IGMPv2 00:00:05 00:02:04 3.0.0.51 225.0.0.3 Vlan 100 IGMPv2 00:00:05 00:02:04 3.0.0.51 225.0.0.4 Vlan 100 IGMPv2 00:00:05 00:02:04 3.0.0.51 Dell#show ip igmp group details Interface Vlan 20 Group 232.1.1.5 Uptime 00:11:22 Expires Never Router mode INCLUDE Last reporter 35.0.0.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information IGMP commands accept only non-VLAN interfaces — specifying VLAN does not yield results.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
• IGMP snooping does not react to Layer 2 topology changes triggered by spanning tree protocol (STP). • IGMP snooping reacts to Layer 2 topology changes multiple spanning tree protocol (MSTP) triggers by sending a general query on the interface that comes in the FWD state. Important Points to Remember for IGMP Querier • The IGMP snooping Querier supports version 2. • You must configure an IP address to the VLAN interface for IGMP snooping Querier to begin.
debug ip igmp snooping Enable debugging of IGMP snooping packets on interfaces and groups. Syntax Parameters debug ip igmp snooping [group address | interface] • To disable debugging of IGMP snooping, use the no debug ip igmp snooping [group address | interface] command. • To disable all debugging, use the undebug all command. snooping Enter the keyword snooping to enable debugging of IGMP snooping. group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information Queriers normally send some queries when a leave message is received prior to deleting a group from the membership database. There may be situations when you require a fast deletion of a group.
Usage Information On the C-Series and S-Series, unregistered multicast data traffic drops when you disable flooding; they do not forward the packets to multicast router ports. On the C-Series and S-Series, in order to disable Layer 2 multicast flooding, disable Layer 3 multicast (no ip multicast-routing). ip igmp snooping last-member-query-interval The last member query interval is the maximum response time inserted into Group-Specific queries sent in response to Group-Leave messages.
ip igmp snooping mrouter Statically configure a VLAN member port as a multicast router interface. Syntax ip igmp snooping mrouter interface interface To delete a specific multicast router interface, use the no igmp snooping mrouter interface interface command. Parameters interface interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
ip igmp snooping querier Enable IGMP querier processing for the VLAN interface. Syntax ip igmp snooping querier To disable IGMP querier processing for the VLAN interface, use the no ip igmp snooping querier command. Defaults Not configured. Command Modes INTERFACE VLAN — (conf-if-vl-n) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
interface detail Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the interface type and slot/port information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Member Ports: Gi 1/17 Dell# show ip igmp snooping mrouter Display multicast router interfaces. Syntax show ip igmp snooping mrouter [vlan number] Parameters Command Modes Command History vlan number • EXEC • EXEC Privilege Enter the keyword vlan then the vlan number. The range is from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
22 Interfaces The commands in this chapter are supported by Dell Networking operating software on the platform. This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) • UDP Broadcast Basic Interface Commands The following commands are for Physical, Loopback, and Null interfaces.
learning-limit (OPTIONAL) Enter the keywords learning-limit to clear unknown source address (SA) drop counters when MAC learning limit is configured on the interface. vlan vlan-id Enter the keyword vlan followed by the interface VLAN number. The range is from 1 to 4094. Defaults Without an interface specified, the command clears all interface counters. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters interface (OPTIONAL) Enter any of the following keywords and slot/port or number to clear counters from a specified interface: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. Defaults Without an interface specified, the command clears all interface dampening counters.
Parameters half-life Enter the number of seconds after which the penalty is decreased. The penalty decreases half after the half-life period expires. The range is from 1 to 30 seconds. The default is 5 seconds. reuse-threshold Enter a number as the reuse threshold, the penalty value below which the interface state is changed to “up”. The range is from 1 to 20000. The default is 750.
Related Commands clear dampening — clears the dampening counters on all the interfaces or just the specified interface. show interfaces dampening — displays interface dampening information. description Assign a descriptive text string to the interface. Syntax description desc_text To delete a description, use the no description command. Parameters desc_text Enter a text string up to 240 characters long. Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
duplex (10/100 Interfaces) Configure duplex mode on any physical interfaces where the speed is set to 10/100. Syntax duplex {half | full} To return to the default setting, use the no duplex command. Parameters half Enter the keyword half to set the physical interface to transmit only in one direction. full Enter the keyword full to set the physical interface to transmit in both directions. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
Parameters rx on Enter the keywords rx on to process the received flow control frames on this port. This is the default value for the receive side. rx off Enter the keywords rx off to ignore the received flow control frames on this port. tx on Enter the keywords tx on to send control frames from this port to the connected device when a higher rate of traffic is received.
• Speeds less than 1 Gig cannot be configured when the asymmetric flow control configuration is on. The following erro returned: Can’t configure speed <1G when Asymmetric flowcontrol is on, config ignored • Dell Networking OS only supports rx on tx on and rx off tx off for speeds less than 1 Gig (Symmetric). NOTE: If you use the disable rx flow control command, Dell Networking recommends rebooting the system.
Related Commands show running-config — displays the flow configuration parameters (non-default values only). show interfaces — displays the negotiated flow control parameters. interface Configure a physical interface on the switch. Syntax Parameters interface interface range interface range Enter one of the following keywords and slot/port or number information: • For a null interface, enter the keyword null then the slot/port information. The Null interface number is 0.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a physical interface. By default, physical interfaces are disabled (shutdown) and are not assigned to an IP address or switchport. To place an interface in Layer 2 mode, ensure that the interface’s configuration does not contain an IP address and enter the switchport command. You can create up to 64 tunnel interfaces.
Slot/Port information need not contain a space before and after the dash. For example. both of the following commands are valid: ; interface group gigabitethernet 1/1 - 5 ; interface group gigabitethernet 1/1-5; . Command Modes Command History Usage Information • For a 1-GigabitEthernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S55, S60, and S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a Management port. The Management port is enabled by default (no shutdown).
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced Usage Information You cannot delete the Null interface. The only configuration command possible in a Null interface is ip unreachables.
• For a Tunnel interface, enter the keyword Tunnel then a number from 1 to 16383. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Example (Overlapping Ports) Dell(conf)#interface range gigabitethernet 2/3 - 2/11, gigabitethernet 2/3 - 2/23 Dell(conf-if-range-gi-2/3-2/23)# Usage Information Only VLAN and port-channel interfaces created using the interface vlan and interface portchannel commands can be used in the interface range command. Use the show running-config command to display the VLAN and port-channel interfaces.
Parameters name Enter up to 16 characters for the macro name. interface, interface,... Enter the keywords interface range and one of the interfaces — slot/port, port-channel, or VLAN number. Select the range of interfaces for bulk configuration. You can enter up to six comma-separated ranges. Spaces are not required between the commas. Comma-separated ranges can include VLANs, portchannels, and physical interfaces.
define interface-range test gigabitethernet 1/1 -3, gigabitethernet 5/1 -47, gigabitethernet 13/1 - 89 Dell(config)#interface range macro test Dell(config-if-range-gi-1/1-3,gi-5/1-47,gi-13/1-89)# Related Commands interface range – configures a range of command (bulk configuration) interface range macro name – runs an interface range macro. interface range macro name Run the interface-range macro to automatically configure the pre-defined range of interfaces.
interface vlan Configure a VLAN. You can configure up to 4094 VLANs. Syntax Parameters interface vlan vlan-id [of-instance{of-id}] of-instance{of-id} Enter the keyword of-instance then the OpenFlow instance ID to add the VLAN to the specified OpenFlow instance. The range is from 1 to 8. NOTE: Associate the OpenFlow instance with the VLAN when the VLAN is created. An existing VLAN cannot be associated with an OpenFlow instance.
interface null — configures a null interface. interface port-channel — configures a port channel group. show vlan — displays the current VLAN configuration on the switch. shutdown — disables/enables the VLAN. tagged — adds a Layer 2 interface to a VLAN as a tagged interface. untagged — adds a Layer 2 interface to a VLAN as an untagged interface. keepalive Send keepalive packets periodically to keep an interface alive when it is not transmitting data.
negotiation auto Enable auto-negotiation on an interface. Syntax negotiation auto To disable auto-negotiation, use the no negotiation auto command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
• Auto-neg Error — typically indicates that both ends of the node are configured with forced-master or forced-slave. CAUTION: Ensure that one end of your node is configured as forced-master and one is configured as forced-slave. If both are configured the same (that is, forced-master or forced-slave), the show interfaces command flaps between an auto-neg-error and forced-master/slave states. You can display master/slave settings with the show interfaces command.
• Up at 1000 Mb/s • Up at 100 Mb/s • Up at 100 Mb/s • Down • Down * You cannot disable auto-negotiation when the speed is set to 1000 or auto. monitor interface Monitor counters on a single interface or all interfaces on a line card. The screen is refreshed every five seconds and the CLI prompt disappears. Syntax monitor interface [interface] To disable monitoring and return to the CLI prompt, press the q key.
Usage Information Version Description pre-Version 6.2.1.0 Introduced on the E-Series. In the Example, the delta column displays changes since the last screen refresh. The following are the monitor command menu options. Example (Single Interface) Key Description systest-3 Displays the host name assigned to the system. monitor time Displays the amount of time since the monitor interface command was entered. time Displays the amount of time the chassis is up (since last reboot).
T - Increase refresh interval q - Quit Example (All Interfaces) t - Decrease refresh interval systest-3 Monitor time: 00:01:31 Refresh Intvl.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If the packet includes a Layer 2 header, the difference between the link MTU and IP MTU (ip mtu command) must be enough bytes to include the Layer 2 header.
portmode hybrid To accept both tagged and untagged frames, set a physical port or port-channel. A port configured this way is identified as a hybrid port in report displays. Syntax portmode hybrid To return a port to accept either tagged or untagged frames (non-hybrid), use the no portmode hybrid command. Defaults non-hybrid Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific.
NOTE: Remove all other configurations on the port before you can remove the hybrid configuration from the port. Example Dell(conf)#interface gigabitethernet 7/1 Dell(conf-if-gi-7/0)#portmode hybrid Dell(conf-if-gi-7/0)#interface vlan 10 Dell(conf-if-vl-10)#untagged gigabitethernet 7/1 Dell(conf-if-vl-10)#interface vlan 20 Dell(conf-if-vl-20)#tagged gigabitethernet 7/1 Dell(conf-if-vl-20)# Example Dell(conf-if-vl-20)#do show interfaces switchport Name: GigabitEthernet 7/1 802.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced Usage Information The output of the show interfaces command displays the configured rate interval, along with the collected traffic data. Related Commands show interfaces — displays information on physical and virtual interfaces.
show config (from INTERFACE RANGE mode) Display the bulk configured interfaces (interface range). Syntax show config Command Modes CONFIGURATION INTERFACE (conf-if-range) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON.
Command Modes Command History Usage Information • EXEC • EXEC Privilege • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For stack-units, enter the keywords stack-unit then the slot/port information. • For a Null interface, enter the keyword null then the Null interface number. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
NOTE: In the CLI output, the power value is rounded to a 3-digit value. For receive/transmit power that is less than 0.000, an snmp query returns the corresponding dbm value even though the CLI displays as 0.000. NOTE: After the counters are cleared, the line-rate continues to increase until it reaches the maximum line rate. When the maximum line rate is reached, there is no change in the line-rate.
Line Description • Number of CRC, overrun, and discarded packets: – CRC = packets with CRC/FCS errors – overrun = number of packets discarded due to FIFO overrun conditions – discarded = the sum of runts, giants, CRC, and overrun packets discarded without any processing Output Statistics: Displays output statistics sent out of the interface including: • Number of packets, bytes, and underruns out of the interface • Packet size and the number of the packets outbound to the interface • Number of Mult
Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Time since last interface status change: 3d17h51m Usage Information The Management port is enabled by default (no shutdown). If necessary, use the ip address command to assign an IP address to the Management port. If two RPMs are installed in your system, use the show redundancy command to display which RPM is the Primary RPM.
Example (Management Ethernet, two IPv6 addresses) Dell#show interfaces managementethernet 1/1 ManagementEthernet 1/1 is up, line protocol is up Hardware is DellForce10Eth, address is 00:01:e8:a0:bf:f3 Current address is 00:01:e8:a0:bf:f3 Pluggable media not present Interface index is 302006472 Internet address is 10.16.130.
LineSpeed auto ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 00:05:12 Queueing strategy: fifo Time since last interface status change: 00:05:12 Related Commands show interfaces configured – displays any interface with a non-default configuration. show inventory (S-Series and Z-Series) – displays the S-Series and Z-Series switch types, components (including media), Dell Networking OS version including hardware identification numbers, and configured protocols.
Last clearing of "show interfaces" counters 00:12:42 Queueing strategy: fifo Input Statistics: 10 packets, 10000 bytes 0 Vlans 0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 10 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts 0 runts, 0 giants, 0 throttles 0 CRC, 0 overrun, 0 discarded Output Statistics: 1 packets, 64 bytes, 0 underruns 1 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte p
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series. 6.5.4.0 Introduced on the E-Series. The following describes the show interfaces gigabitethernet command following example. Mode Control Indicates if auto negotiation is enabled. If so, indicates the selected speed and duplex. Mode Status Displays auto negotiation fault information.
• 10MB Example Dell#show interfaces gigabitethernet 1/1 phy Mode Control: SpeedSelection: 10b AutoNeg: ON Loopback: False PowerDown: False Isolate: False DuplexMode: Full Mode Status: AutoNegComplete: False RemoteFault: False LinkStatus: False JabberDetect: False AutoNegotation Advertise: 100MegFullDplx: True 100MegHalfDplx: True 10MegFullDplx: False 10MegHalfDplx: True Asym Pause: False Sym Pause: False AutoNegotiation Remote Partner's Ability: 100MegFullDplx: False 100MegHalfDplx: False 10MegFullDplx:
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then the slot/port information. The range is from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
show interfaces switchport Display only virtual and physical interfaces in Layer 2 mode. This command displays the Layer 2 mode interfaces’ IEEE 802.1Q tag status and VLAN membership. Syntax Parameters Command Modes Command History show interfaces switchport [interface | stack-unit unit-id ] interface • EXEC • EXEC Privilege (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a port channel interface, enter the keywords port-channel then a number.
Example Items Description Name Displays the interface’s type, slot/port number. 802.1QTagged Displays whether if the VLAN tagged (“True”), untagged (“False”), or hybrid (“Hybrid”), which supports both untagged and tagged VLANs by port 13/0. Vlan membership Lists the VLANs to which the interface is a member. Starting with Dell Networking OS version 7.6.1, this field can display native VLAN membership by port 13/0. Dell#show interfaces switchport Name: GigabitEthernet 13/1 802.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on theS6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Interfaces Line Description RX Power Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. Temp High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Voltage High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Bias High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power High Warning threshold Factory-defined setting. Value can differ between SFP and SFP+.
Line Description Rate Select state This is the digital state of the SFP rate_select input pin. RS state This is the reserved digital state of the pin AS(1) per SFF-8079 and RS(1) per SFF-8431. Tx Disable state If the admin status of the port is down then this flag is set to true. Temperature High Alarm Flag This can be either true or false, depending on the Current voltage value displayed above.
Example Line Description Rx Power Low Warning Flag This can be either true or false, depending on the Current Rx power value displayed above. Dell#show interfaces GigabitEthernet 1/1 transceiver SFP is present.
SFP 1 Tx Disable state = False =================================== SFP 1 Temperature High Alarm Flag = False SFP 1 Voltage High Alarm Flag = False SFP 1 Tx Bias High Alarm Flag = False SFP 1 Tx Power High Alarm Flag = False SFP 1 Rx Power High Alarm Flag = False SFP 1 Temperature Low Alarm Flag = False SFP 1 Voltage Low Alarm Flag = False SFP 1 Tx Bias Low Alarm Flag = False SFP 1 Tx Power Low Alarm Flag = False SFP 1 Rx Power Low Alarm Flag = True =================================== !-------output truncate
Input Statistics: 0 packets, 0 bytes Output Statistics: 0 packets, 0 bytes, 0 underruns Related Commands show interfaces — displays information on a specific physical interface or virtual interface. show range Display all interfaces configured using the interface range command. Syntax show range Command Modes INTERFACE RANGE (config-if-range) Command History This guide is platform-specific.
show running-config ecmp-group Display interfaces, LAG, or LAG link bundles being monitored for uneven traffic distribution using the ecmp-group monitoring enable command. The ECMP group could have a LAG or a list of 10G/40 interfaces (not just LAG link-bundles). Syntax show running-config ecmp-group Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information The shutdown command marks a physical interface as unavailable for traffic. To discover if an interface is disabled, use the show ip interface brief command. Disabled interfaces are listed as down. Disabling a VLAN or a port channel causes different behavior.
NOTE: When this setting is enabled, only 100oBase-FX optics are supported on the LC-EH-GE-50P or the LC-EJ-GE-50P card. auto Enter the keyword auto to set the interface to auto-negotiate its speed. Autonegotiation is enabled. For more information, refer to negotiation auto. Defaults auto Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
speed (Management interface) Set the speed for the Management interface. Syntax speed {10 | 100 | 1000 | auto} To return to the default setting, use the no speed command. Parameters 10 Enter the keyword 10 to set the interface’s speed to 10 Mb/s. 100 Enter the keyword 100 to set the interface’s speed to 10/100 Mb/s. 1000 Enter the keyword 1000 to set the interface to auto-negotiate its speed. auto Enter the keyword auto to set the interface to auto-negotiate its speed.
switchport Place an interface in Layer 2 mode. Syntax switchport [backup interface {gigabit slot/port | tengigabit slot/port | fortyGigE slot/port | port-channel number}] To remove an interface from Layer 2 mode and place it in Layer 3 mode, enter the no switchport command. If a switchport backup interface is configured, first remove the backup configuration.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If an IP address or VRRP group is assigned to the interface, you cannot use the switchport command on the interface. To use the switchport command on an interface, only the no ip address and no shutdown statements must be listed in the show config output.
Command Modes EIS Mode (conf-mgmt-eis) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2.(0.0) Introduced on the Z9000, S4810, and S4820T.
Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2.(0.0) Introduced on the Z9000, S4810, and S4820T.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. show ip management-eis-route Display the management routes used by EIS. Syntax show ip management-eis-route Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
ntp radius sflow-collector snmp ssh syslog tacacs telnet tftp : : : : : : : : : 0 0 0 0 0 0 0 0 0 show management application pkt-fallback-cntr Display the number of packets for each application type that have been rerouted to the default routing table due to management port or route lookup failure. Syntax show management application pkt—fallback-cntr Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific.
NOTE: The Dell Networking OS implementation of LAG or Port Channel requires that you configure a LAG on both switches manually. For information about Dell Networking OS link aggregation control protocol (LACP) for dynamic LAGs, refer to the Link Aggregation Control Protocol (LACP) chapter. For more information about configuring and using Port Channels, refer to the Dell Networking OS Configuration Guide. channel-member Add an interface to the Port Channel, while in INTERFACE PORTCHANNEL mode.
You cannot add an interface to a Port Channel if the interface contains an IP address in its configuration. Only the shutdown, description, mtu, and ip mtu commands can be configured on an interface if it is added to a Port Channel. The mtu and ip mtu commands are only available when the chassis is in Jumbo mode. Link MTU and IP MTU considerations for Port Channels are: • All members must have the same link MTU value and the same IP MTU value.
Command Modes PORT-CHANNEL FAILOVER-GROUP (conf-po-failover-grp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description Version 8.3.12.0 Introduced on S4810. Version 8.3.11.1 Introduced on Z9000. Version 8.1.1.0 Introduced on E-Series ExaScale. Version 7.6.1.0 Introduced on S-Series. Version 7.5.1.0 Introduced on C-Series. pre-Version 6.2.1.0 Introduced on E-Series. Port Channel interfaces are logical interfaces and can be either in Layer 2 mode (by using the switchport command) or Layer 3 mode (by configuring an IP address).
Parameters number Enter the number of links in a LAG that must be in “oper up” status. The range is from 1 to 16. The default is 1. Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. Usage Information This feature groups two LAGs to work in tandem as a supergroup.
shutdown Dell(conf-if-po-1)# show interfaces port-channel Display information on configured Port Channel groups. Syntax Parameters Command Modes Command History show interfaces port-channel [channel-number] [brief] channel-number For a Port Channel interface, enter the keyword port-channel then a number. For the C-Series and S-Series, the range is from 1 to 128.
Example Field Description Internet address... States whether an IP address is assigned to the interface. If an IP address is assigned, that address is displayed. MTU 1554... Displays link and IP MTU. LineSpeed Displays the interface’s line speed. For a port channel interface, it is the line speed of the interfaces in the port channel. Members in this... Displays the interfaces belonging to this port channel. ARP type:... Displays the ARP type and the ARP timeout value for the interface.
User Information The following describes the show interfaces port-channel brief command shown in the following example. Field Description LAG Lists the port channel number. Mode Lists the mode: Status Example • L3 — for Layer 3 • L2 — for Layer 2 Displays the status of the port channel. • down — if the port channel is disabled (shutdown) • up — if the port channel is enabled (no shutdown) Uptime Displays the age of the port channel in hours:minutes:seconds.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. source-ip address Enter the keywords source-ip then the IP source address in IP address format. destination-ip address Enter the keywords destination-ip then the IP destination address in IP address format. source-port number Enter the keywords source-port then the source port number. The range is from 1 to 65536. The default is None.
The following example shows the show port-channel-flow outgoing-port-channel number incoming-interface interface source-mac address destination-mac address Example • Load-balance is configured for MAC • Load-balance is configured for IP 4-tuple/2-tuple • A non-IP payload is going out of Layer 2 LAG interface that is a member of VLAN with an IP address Dell#show port-channel-flow outgoing-port-channel 1 incoming-interface gi 3/3 source-mac 00:00:50:00:00:00 destination-mac 00:00:a0:00:00:00 Egress Po
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S Series. 7.6.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. The interface must be enabled to run the test or an error message is generated: Dell#tdr-cable-test gigabitethernet 5/2 %Error: Interface is disabled GI 5/2 Syslog messages are generated when the link flaps during TDR tests.
Usage Information If the TDR test has not been run, an error message is generated: %Error: Please run the TDR test first The following describes the TDR test status. Status Definition OK Status: Terminated TDR test is complete, no fault is detected on the cable, and the test is terminated. Length: 92 (+/- 1) meters, Status: Shorted A short is detected on the cable. The location, in this Example is 92 meters. The short is accurate to plus or minus one meter.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Pre-version 8.3.7.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. Pre-version 8.3.7.0 Introduced on the E-Series ExaScale. Usage Information When a UDP broadcast packet is flooded out of an interface, and the outgoing interface is configured using this command, the outgoing packet’s IP destination address is replaced with the configured broadcast address. Related Commands debug ip udp-helper — enables debug and displays the debug information on a console.
If you only configure the ip udp-helper udp-port command, all the UDP broadcast traffic is flooded, including ports 67/68 traffic if those ports are part of the udp-port-list. Related Commands ip helper-address — configures the destination broadcast or host address for the DHCP server. debug ip udp-helper — enables debug and displays the debug information on a console. show ip udp-helper — displays the configured UDP helpers on all interfaces.
Syntax ip http source-interface interface To delete an interface, use theno ip http source-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
23 Enhanced Validation of Interface Ranges This functionality is supported on the platform. You can avoid specifying spaces between the range of interfaces, separated by commas, that you configure by using the interface range command. For example, if you enter a list of interface ranges, such as interface range te 50/1,gi 3/9, this configuration is considered valid. The comma-separated list is not required to be separated by spaces in between the ranges.
24 Internet Protocol Security (IPSec) Internet protocol security (IPSec) is an end-to-end security scheme for securing IP communications by authenticating and encrypting all packets in a session. Use IPSec between hosts, gateways, or hosts and gateways. IPSec uses a series of protocol functions to achieve information security: • Authentication Headers (AH) — Connectionless integrity and origin authentication for IP packets.
esp-authentication esp-encryption • md5 — Use Message Digest 5 (MD5) authentication. • sha1 — Use Secure Hash Algorithm 1 (SHA-1) authentication. • null — Causes an encryption policy configured for the area to not be inherited on the interface. Enter the keywords esp-authentication then the transform type of operation to apply to traffic. The transform type represents the encryption or authentication applied to traffic. • md5 — Use Message Digest 5 (MD5) authentication.
crypto ipsec policy Create a crypto policy used by ipsec. Syntax crypto ipsec policy name seq-num ipsec-manual To delete a crypto policy entry, use the no crypto ipsec policy name seq-num ipsec-manual command. Parameters name Enter the name for the crypto policy set. seq-num Enter the sequence number assigned to the crypto policy entry. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. match Apply an match filter to the crypto policy.
Example • Configure match for bi-directional traffic for optimal routing. • Only TCP is supported. match match match match match match match match 0 1 2 3 4 5 6 7 tcp tcp tcp tcp tcp tcp tcp tcp a::1 /128 0 a::2 /128 23 a::1 /128 23 a::2 /128 0 a::1 /128 0 a::2 /128 21 a::1 /128 21 a::2 /128 0 1.1.1.1 /32 0 1.1.1.2 /32 23 1.1.1.1 /32 23 1.1.1.2 /32 0 1.1.1.1 /32 0 1.1.1.2 /32 21 1.1.1.1 /32 21 1.1.1.2 /32 0 session-key Specify the session keys used in the crypto policy entry.
Usage Information Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. • This command is only available in the ipsec-manual model. • The key information entry is associated with the global method for enabling clear text or encrypted display in the running config. show crypto ipsec transform-set Display the transform set configuration. Syntax show crypto ipsec transform-set name Parameters name Enter the name of the transform set.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.2(0.2) Example Introduced on the Z9000, S4810, and S4820T.
Defaults none Command Modes CONFIG-CRYPTO-POLICY Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 684 Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T.
25 IPv4 Routing The basic IPv4 commands are supported by Dell Networking operating system on the platform. arp To associate an IP address with a MAC address in the switch, use address resolution protocol (ARP). Syntax arp [vrf vrf-name] ip-address mac-address interface To remove an ARP address, use the no arp ip-address command. Parameters vrf vrf-name Enter a VRF name to configure an ARP entry for that VRF. Use the VRF option after the keyword arp to configure a static arp on that particular VRF.
Usage Information Version Description 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Usage Information This timer is an exponential backoff timer. Over the specified period, the time between ARP requests increases. This behavior reduces the potential for the system to slow down while waiting for a multitude of ARP responses.
Beginning with Dell Networking OS version 8.3.1.0, when a gratuitous ARP is received, Dell Networking OS installs an ARP entry on all three CPUs. arp max-entries Enables you to configure the maximum number of ARP entries per VRF that are allowed for IPv4.. Syntax arp max-entries [vrf vrf-name] max-number Parameters vrf vrf-name Enter the name of a specific VRF for which you want to configure maximum number of ARP entries that IPv4 allows.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Related Commands Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. show interfaces — displays the ARP timeout value for all available interfaces. clear arp-cache Clear the dynamic ARP entries from a specific interface or optionally delete (no-refresh) ARP entries from the content addressable memory (CAM).
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. clear ip fib stack-unit Clear all FIB entries in the specified stack unit (use this command with caution, refer to Usage Information.) Syntax clear ip fib stack-unit unit-number vrf vrf-name Parameters unit-number Enter the number of the stack unit. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to clear all FIB entries corresponding to that VRF.
Parameters * Enter an asterisk (*) to clear all learned IP routes. ip-address mask Enter a specific IP address and mask in dotted decimal format to clear that IP address from the routing table. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters all Enter the keyword all to clear all TCP statistics maintained on all switch processors. cp (OPTIONAL) Enter the cp to clear only statistics from the Control Processor. rp1 (OPTIONAL) Enter the keyword rp1 to clear only the statistics from Route Processor 1. rp2 (OPTIONAL) Enter the keyword rp2 to clear only the statistics from Route Processor 2. Command Modes EXEC Privilege Command History This guide is platform-specific.
count value • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. (OPTIONAL) Enter the keyword count then the count value. The range is from 1 to 65534. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 696 Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Related Commands ip helper-address – specifies the destination broadcast or host address for the DHCP server request. ip helper-address hop-count disable – disables the hop-count increment for the DHCP relay agent. debug ipv6 dhcp To enable debug logs for DHCPv6 relay agent transactions. Syntax debug ipv6 dhcp To disable the debug logs for dhcpv6 relay agent transactions, use the debug ipv6 dhcp command. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
count value (OPTIONAL) Enter the keyword count then the count value. The range is from 1 to 65534. The default is Infinity. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON.
Parameters access-group name Enter the keyword access-group then the access list name (maximum 16 characters) to limit the debug output based on the defined rules in the ACL. count value (OPTIONAL) Enter the keyword count then the count value. The range is from 1 to 65534. The default is Infinity. interface (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
Field Description d= Lists the destination address of the packet and the name of the interface (in parentheses) through which the packet is being sent out on the network. len Displays the packet’s length. sending, rcvd, fragment, sending broad/multicast proto, unroutable The last part of each line lists the status of the packet. TCP src= Displays the source and destination ports, the sequence number, the acknowledgement number, and the window size of the packets in that TCP packets.
• User Datagram Protocol (udp) In the case of ambiguous access control list rules, the debug ip packet access-control command is disabled. A message appears identifying the error (refer to the Example below).
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. You must be in INTERFACE mode before you add an IP address to an interface. Assign an IP address to an interface prior to entering ROUTER OSPF mode. ip directed-broadcast Enables the interface to receive directed broadcast packets. Syntax ip directed-broadcast To disable the interface from receiving directed broadcast packets, use the no ip directedbroadcast command.
ip domain-list Configure names to complete unqualified host names. Syntax ip domain-list name To remove the name, use the no ip domain-list name command. Parameters name Enter a domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip domain-lookup To address resolution (that is, DNS), enable dynamic host-name. Syntax ip domain-lookup To disable DNS lookup, use the no ip domain-lookup command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ip domain-name Configure one domain name for the switch. Syntax ip domain-name name To remove the domain name, use the no ip domain-name command. Parameters name Enter one domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip helper-address Specify the address of a DHCP server so that DHCP broadcast messages can be forwarded when the DHCP server is not on the same subnet as the client. Syntax ip helper-address ip-address To remove a DHCP server address, use the no ip helper-address command. Parameters ip-address Enter an IP address in dotted decimal format (A.B.C.D). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
ip helper-address hop-count disable Disable the hop-count increment for the DHCP relay agent. Syntax ip helper-address hop-count disable To re-enable the hop-count increment, use the no ip helper-address hop-count disable command. Defaults Enabled; the hops field in the DHCP message header is incremented by default. Command Modes CONFIGURATION Command History This guide is platform-specific.
To remove an IP host, use the no ip host name [ip-address] command. Parameters name Enter a text string to associate with one IP address. ip address Enter an IP address, in dotted decimal format, to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes CONFIGURATION Command History Usage Information • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number.
NOTE: When you configure the capability to enable the loopback IP address to be sent for easy debugging and diagnosis (IP addresses of the devices for which the ICMP source interface is configured), the source IP address of the outgoing ICMP error message is modified, although the packets are not sent out using the configured interface.
ip max-frag-count Set the maximum number of fragments allowed in one packet for packet re-assembly. Syntax ip max-frag-count count To place no limit on the number of fragments allowed, use the no ip max-frag-count command. Parameters count Enter a number for the number of fragments allowed for re-assembly. The range is from 2 to 256. Defaults No limit is set on number of fragments allowed. Command Modes CONFIGURATION Command History This guide is platform-specific.
max-number Enter the maximum number of protocol routes that a VRF RTM can hold. The range is from 0 to 7500. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.4.(0.0) Introduced on the S4810 and S4820T.
Usage Information When you enter the no mtu command, Dell Networking OS reduces the ip mtu value to 1536 bytes. To return the IP MTU value to the default, use the no ip mtu command. Starting with Dell Networking OS Release 9.2(0.2), the ip mtu command is not supported to configure the IP MTU value that is used when the IP packet is fragmented. Instead of having to configure the IP MTU value, this value is automatically computed by the software when you configure an interface.
ip name-server Enter up to six IPv4 addresses of name servers. The order you enter the addresses determines the order of their use. Syntax ip name-server ipv4-address [ipv4-address2...ipv4-address6] To remove a name server, use the no ip name-server ip-address command. Parameters ipv4-address Enter the IPv4 address, in dotted decimal format, of the name server to be used. ipv4-address2... ipv4-address6 (OPTIONAL) Enter up five more IPv4 addresses, in dotted decimal format, of name servers to be used.
ip proxy-arp Enable proxy ARP on an interface. Syntax ip proxy-arp To disable proxy ARP, use the no ip proxy-arp command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.
mask Enter the mask in the slash prefix format (/x) of the destination IP address. ip-address Enter the IP address of the forwarding router in dotted decimal format. interface Enter one of the following keyword followed by the slot/port number: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for tunnel interface type. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.
Dell(conf)#do show running-config | grep route ip route vrf test 1.1.1.0/24 4.4.4.2 weight 100 ip route vrf test 1.1.1.0/24 6.6.6.2 weight 200 Related Commands show ip route — views the switch routing table. ip source-route Enable Dell Networking OS to forward IP packets with source route information in the header. Syntax ip source-route To drop packets with source route information, use the no ip route-source command. Defaults Enabled.
To disable the generation of ICMP messages, use the no ip unreachables command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
mac {dest-mac | source-dest-mac | source-mac} tcp-udp enable Enter the keywords to distribute MAC traffic based on the following criteria: • dest-mac — Uses the destination MAC address, VLAN, Ethertype, source module ID and source port ID fields to hash. The hashing mechanism returns a 3-bit index indicating which port the packet should be forwarded. • source-dest-mac — Uses the destination and source MAC address, VLAN, Ethertype, source module ID and source port ID fields to hash.
load-balance hg Choose the traffic flow parameters the hash calculation uses while distributing the traffic across internal higig links.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Added support for IPv6. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.
tengigabitethernet Enter the keyword tengigabitethernet to specify a ten Gigabit Ethernete interface. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
NOTE: Use this attribute to start a BGP instance for either a specific address family corresponding to the default VRF or an IPv4 address family corresponding to a non-default VRF. interface interface (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.8.1.0 Augmented to display local ARP entries learned from private VLANs (PVLANs). 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Example (Private VLAN) NOTE: In this example, Line 1 shows community VLAN 200 (in primary VLAN 10) in a PVLAN. Line 2 shows primary VLAN 10. Dell#show arp Protocol Address Age(min) Hardware Address Interface VLAN CPU --------------------------------------------------------------Internet 5.5.5.1 - 00:01:e8:43:96:5e Vl 10 pv 200 Internet 5.5.5.10 - 00:01:e8:44:99:55 Vl 10 Internet 10.1.2.4 1 00:01:e8:d5:9e:e2 Ma 1/1 Internet 10.10.10.4 1 00:01:e8:d5:9e:e2 Ma 1/1 Internet 10.16.127.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced. arp retries — sets the number of ARP retries in case the system does not receive an ARP reply in response to an ARP request. show hosts View the host table and DNS configuration.
Field Description Default domain... Displays the domain name (if configured). Name/address lookup... States if DNS is enabled on the system. • If DNS is enabled, the Name/Address lookup is domain service. • If DNS is not enabled, the Name/Address lookup is static mapping Name servers are... Lists the name servers, if configured. Host Displays the host name assigned to the IP address.
Parameters stack-unit-number Enter the stack-unit ID. The unit ID range is from 1 to 6. port-set pipenumber Enter the keyword port-set then the number of the stack unit’s port-pipe. The unit ID range is to 0. network mask [longer-prefixes [ecmp-group detail]] (OPTIONAL) Enter the IP address and mask of a route to CAM entries for that route only. You can one of the following keywords to filter results.
Example Field Description Mac Addr Displays the next-hop router’s MAC address. Port Displays the egress interface. • CP = control processor • Gi = Gigabit Ethernet interface • Te = 10–Gigabit Ethernet interface Dell#show ip cam stack-unit 3 po 0 1.1.1.0/24 longer-prefixes Destination EC C VId Mac-Addr Port -------------------------------------------------------------------1.1.1.2/32 0 0 3000 00:05:00:00:00:02 Gi 3/44 1.1.1.1/32 0 1 0 00:00:00:00:00:00 CP 1.1.1.
Command Modes Command History longer-prefixes (OPTIONAL) Enter the keywords longer-prefixes to view all routes with a common prefix. summary (OPTIONAL) Enter the keyword summary to view the total number of prefixes in the FIB. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Dell#show ip route S 10.1.1.0/24 S S Example (Show command output with Weighted ECMP Enabled) 20.1.1.0/24 100.1.1.0/24 via via via via via 1.1.1.2, Vl 10 2.1.1.2, Vl 20 3.1.1.2, Vl 30 10.1.1.0, weight 7 20.1.1.0, weight 1 Dell#show ip fib stack-unit 1 Destination Gateway First-Hop Mac-Addr Port -----------------------------------------------------------------------------------0.0.0.0/0 0.0.0.0 00:00:00:00:00:00 CP 1.1.1.0/24 Direct, Lo 0 0.0.0.0 00:00:00:00:00:00 CP 1.1.1.1/32 via 127.0.0.1 127.0.0.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series.
Command Modes Command History • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 1 to 11. The port range is 1. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Example Lines Description TenGigabitEthernet 1/1... Displays the interface’s type, slot/port, and physical and line protocol status. Internet address... States whether an IP address is assigned to the interface. If an IP address is assigned, that address is displayed. IP MTU is... Displays IP MTU value. Inbound access... Displays the name of the configured incoming access list. If none is configured, the phrase “not set” is displayed. Proxy ARP...
show ip management-route View the IP addresses assigned to the Management interface. Syntax show ip management-route [all | connected | summary | static] Parameters Command Modes Command History all (OPTIONAL) Enter the keyword all to view all IP addresses assigned to all Management interfaces on the switch. connected (OPTIONAL) Enter the keyword connected to view only routes directly connected to the Management interface.
show ipv6 management-route Display the IPv6 static routes configured for the management interface. Syntax Parameters show ipv6 management-route [all | connected | summary | static] all (OPTIONAL) Enter the keyword all to view all IP addresses assigned to all Management interfaces on the switch. connected (OPTIONAL) Enter the keyword connected to view only routes directly connected to the Management interface.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 738 Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
show ip route View information, including how they were learned, about the IP routes on the switch. Syntax Parameters show ip route [vrf vrf-name] hostname | ip-address [mask] [longer-prefixes] | list prefix-list | protocol [process-id | routing-tag] | all | connected | static | summary] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the VRF name to list the routes in the route table of a specific VRF.
The following is a list of the Dell Networking OS version history for this command. Usage Information 740 IPv4 Routing Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Field Description Last Change Identifies when the route was last changed or configured. The weight for weighted ECMP route calculations is displayed for each path in the route in show ip route command. The ECMP weight is displayed only if weighted ECMP is enabled using the ip ecmp weighted command is enabled. If weighted ECMP is disabled, the show ip route command does not show the weighted ECMP route information.
----------------- ----------S 1.1.1.0/24 100 C 4.4.4.0/24 1/4 00:01:32 C 6.6.6.0/24 1/16 00:01:25 4.4.4.2, via Gi 1/4 , weight 1/0 00:00:01 6.6.6.2, via Gi 1/16, weight 200 Direct, Gi 0/0 Direct, Gi 0/0 Dell# show ip route 1.1.1.0/24 Routing entry for 1.1.1.0/24 Known via "static", distance 1, metric 0 Last update 00:05:01 ago Routing Descriptor Blocks: * 4.4.4.2, via GigabitEthernet 1/4 weight 100 * 6.6.6.
show ip route list Display IP routes in an IP prefix list. Syntax Parameters Command Modes Command History show ip route vrf vrf-name list prefix-list prefix-list Enter the name of a configured prefix list. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to display IP routes in an IP prefix list corresponding to that VRF. • EXEC • EXEC Privilege This guide is platform-specific.
R C Related Commands 2.1.3.0/24 2.1.4.0/24 via 2.1.4.1, Gi 4/43 Direct, Gi 4/43 120/1 0/0 3d1h 3d1h ip prefix-list — enters CONFIGURATION-IP PREFIX-LIST mode and configures a prefix list. show ip prefix-list summary — displays a summary of the configured prefix lists. show ip route summary View a table summarizing the IP routes in the switch. Syntax show ip route vrf vrf-name summary Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Column Heading Description Example ospf 100 If routing protocols (OSPF, RIP) are configured and routes are advertised, then information on those routes is displayed. Total 1388 active... Displays the number of active and non-active routes and the memory usage of those routes. If there are no routes configured in the Dell Networking OS, this line does not appear.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 F10 Monitoring MIB available for the ip traffic statistics command. pre-6.1.1.0 Introduced on the E-Series.
The Dell Monitoring MIB provides access to the following statistics. Example • IP Statistics: Bcast: Received: Object = f10BcastPktRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.1 • IP Statistics: Bcast: Sent: Object = f10BcastPktSent, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.2 • IP Statistics: Mcast: Received: Object = f10McastPktRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.3 • IP Statistics: Mcast: Sent: Object = f10McastPktSent, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.
rp2 Enter the keyword rp2 to view only TCP statistics from Route Processor 2. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.
Example Field Description 25 control packets... Displays the number of control packets sent and the number retransmitted. 11603 data packets... Displays the number of data packets sent. 24 data packets retransmitted Displays the number of data packets resent. 355 ack.. Displays the number of acknowledgement packets sent and the number of packet delayed. 0 window probe... Displays the number of window probe and update packets sent. 7 Connections initiated...
26 IPv6 Access Control Lists (IPv6 ACLs) IPv6 ACLs and IPv6 Route Map commands are supported on Dell Networking platform. NOTE: For IPv4 ACL commands, refer to the Access Control Lists (ACL) chapter. Important Points to Remember • Certain platforms require manual CAM usage space allotment. For more information, refer to the cam-acl command. • Egress IPv6 ACL and IPv6 ACL on the Loopback interface is not supported. • Reference to an empty ACL permits any traffic.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series.
Example Version Description 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series.
Ipv6Acl : Ipv4Qos : L2Qos : 4 2 3 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs. permit icmp To allow all or specific internet control message protocol (ICMP) messages, configure a filter.
permit To configure a filter that matches the filter criteria, select an IPv6 protocol number, ICMP, IPv6, TCP, or UDP. Syntax permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command ip-protocol-number Enter an IPv6 protocol number. The range is from 0 to 255.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. ipv6 access-list Configure an access list based on IPv6 addresses or protocols.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series. Increased the name string to accept up to 140 characters. Prior to version 7.8.1.0, names are up to 16 characters long. 7.4.1.0 Introduced on the E-Series TeraScale. The number of entries allowed per ACL is hardware-dependent.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.4.2.0 Introduced on the E-Series TeraScale. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 4 FP Blocks.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
27 IPv6 Basics IPv6 basic commands are supported on the Dell Networking OS. NOTE: For information about the Dell Networking operating software version and platform that supports IPv6 in each software feature, refer to the IPv6 Addressing chapter of the Dell Networking OS Configuration Guide. clear ipv6 fib Clear (refresh) all forwarding information base (FIB) entries on a linecard or stack unit.
clear ipv6 route Clear (refresh) all or a specific route from the IPv6 routing table. Syntax clear ipv6 route [vrf vrf-name] {* | ipv6-address prefix-length} Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to clear the IPv6 routes corresponding to that VRF. * Enter the * to clear (refresh) all routes from the IPv6 routing table. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. maximum dynamic-routes-ipv6 Specify the maximum number of dynamic (protocol) IPv6 routes a VRF can have. Syntax maximum dynamic-routes—ipv6 limit {warn-threshold threshold-value | warningonly} To remove the limit on the maximum number of IPv6 routes used, use the no maximum dynamicroutes-ipv6 command.
ipv6 address autoconfig Configure IPv6 address auto-configuration for the management interface. Syntax ipv6 address autoconfig To disable the address autoconfig operation on the management interface, use the no ipv6 address autoconfig command. Default Disabled Command Modes INTERFACE (management interface only) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
To remove the IPv6 address, use the no ipv6 address {ipv6-address prefix-length} command. Parameters ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
ipv6 address 2002:1:2::3 /96 no shutdown ipv6 address eui64 Configure IPv6 EUI64 address configuration on the interface. Syntax ipv6 address {ipv6-address prefix-length} eui64 To disable IPv6 EUI64 address autoconfiguration, use the no ipv6 address {ipv6-address prefix-length} eui64 command. Parameters ipv6-address prefixlength Enter the IPv6 prefix in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128.
ipv6 control-plane icmp error-rate-limit Configure the maximum number of ICMP error packets per second that can be sent per second. Syntax ipv6 control-plane icmp error-rate-limit {1-200} To restore the default value, use the no ipv6 control-plane icmp error-rate-limit command. Parameters pps Enter the maximum number of error packets generated per second. The range is from 1 to 200, where 0 disables the rate-limiting.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. If the flowlabel value is already set for BGP or SSH, the system defaults to the already configured value. All packets on the same connection are considered part of the same flow by the system. For new connections, set the new flowlabel to zero.
ipv6 name-server Enter up to six IPv6 addresses of name servers. The order you enter the addresses determines the order of their use. Syntax ipv6 name-server ipv6-address [ipv6-address2... ipv6-address6] To remove a name server, use the no ipv6 name—server ipv6–address command. Parameters ipv6-address Enter the IPv6 address (X:X:X:X::X) of the name server to be used. Note: The :: notation specifics successive hexadecimal fields of zeros. ipv6-address2...
Default 3 attempts Command Modes INTERFACE (management interface only) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Example Dell(conf-if-gi-1/1)#ipv6 nd dns-server 1000::1 1 ipv6 nd prefix Specify which IPv6 prefixes are included in Neighbor Advertisements. Syntax Parameters ipv6 nd prefix {ipv6-prefix | prefix-length | default} [no-advertise] | [no-autoconfig] [no-rtr-address] [off-link] [lifetime {valid | infinite} {preferred | infinite}] ipv6-prefix Enter an IPv6 prefix. prefix-length Enter the prefix then the prefix length. The length range is from 0 to 128.
Usage Information Version Description 8.3.2.0 Introduced on the E-Series TeraScale, C-Series, and S-Series. By default, all prefixes configured as addresses on the interface are advertised. This command allows control over the individual parameters per prefix; you can use the default keyword to use the default parameters for all prefixes. If a prefix has been configured with lifetime parameter values, the default values cannot be applied using the ipv6 nd prefix default no-autoconfig command.
ipv6-address (OPTIONAL) Enter the forwarding router IPv6 address in the x:x:x:x::x format. NOTE: The :: notation specifies successive hexadecimal fields of zeros. distance (OPTIONAL) Enter a number as the metric distance assigned to the route. The range is from 1 to 255. tag value (OPTIONAL) Enter the keyword tag then a tag value number. The range is from 1 to 4294967295.
You can specify the weight value only to destination address and not on the egress port. A route is considered for weighted ECMP calculations only if each paths corresponding to that route is configured with a weight.
• static and protocol learned routes are removed from RTM and from the CAM; packet forwarding to these routes is terminated • connected routes and resolved neighbors remain in the CAM and new IPv6 neighbors are still discoverable • additional protocol adjacencies (OSPFv3 and BGP4) are brought down and no new adjacencies are formed • the IPv6 address family configuration (under router bgp) is deleted • IPv6 Multicast traffic continues to flow unhindered show ipv6 cam stack-unit Displays the IPv6 CA
Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.1 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. Usage Information NOTE: If a route has a mask greater than 64, no output is displayed and no output is displayed for show ipv6 cam stack-unit unit-number port-set {0-1} ipv6-address, but an equivalent /64 entry would be listed in the show ipv6 cam stack-unit unit-number port-set {0-1} output.
show ipv6 fib stack-unit View all FIB entries. Syntax Parameters show ipv6 fib [vrf vrf-name] stack-unit unit-number [summary | ipv6address] vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display neighbors corresponding to that VRF. slot-number Enter the number of the stack unit. summary (OPTIONAL) Enter the keyword summary to view a summary of entries in IPv6 cam.
show ipv6 flowlabel-zero Display the flow label zero setting. Syntax show ipv6 flowlabel-zero Default Disabled Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.
Defaults Command Modes Command History brief (OPTIONAL) View a summary of IPv6 interfaces. configured (OPTIONAL) View information on all IPv6 configured interfaces. gigabitethernet (OPTIONAL) View information for an IPv6 gigabitethernet interface. managementethern et slot/ port (OPTIONAL) View information on an IPv6 Management port. Enter the slot number (0-1) and port number zero (0). loopback (OPTIONAL) View information for IPv6 Loopback interfaces.
Joined Group address(es): ff02::1 ff02::2 ff02::1:ff00:2 ff02::1:ffa7:497e ND MTU is 0 ICMP redirects are not sent DAD is enabled, number of DAD attempts: 3 ND reachable time is 39610 milliseconds ND base reachable time is 30000 milliseconds ND advertised reachable time is 0 milliseconds ND advertised retransmit interval is 0 milliseconds ND router advertisements are sent every 198 to 600 seconds ND router advertisements live for 1800 seconds ND advertised hop limit is 64 IPv6 hop limit for originated packe
ND MTU is 0 ICMP redirects are not sent DAD is enabled, number of DAD attempts: 3 ND reachable time is 20410 milliseconds ND base reachable time is 30000 milliseconds ND advertised reachable time is 0 milliseconds ND advertised retransmit interval is 0 milliseconds ND router advertisements are sent every 198 to 600 seconds ND router advertisements live for 1800 seconds ND advertised hop limit is 64 IPv6 hop limit for originated packets is 64 show ipv6 mld_host Display the IPv6 MLD host counters.
Valid MLD Packets Reports Leaves MLDv2 Queries MLDv1 Queries Errors: Malformed Packets: 97962 79962 ---18000 0 18036 18034 0 ------- 4510 show ipv6 route Displays the IPv6 routes.
The following is a list of the Dell Networking OS version history for this command. Usage Information Example (S-Series) Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale.
Codes: C - connected, L - local, S - static, R - RIP, B - BGP, IN - internal BGP, EX - external BGP,LO - Locally Originated, O - OSPF, IA - OSPF inter area, N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2, E1 - OSPF external type 1, E2 - OSPF external type 2, i - IS-IS, L1 - IS-IS level-1, L2 - IS-IS level-2, IA - IS-IS inter area, * - candidate default, Gateway of last resort is not set C C S L Dell# Destination Dist/Metric, Gateway, Last Change --------------------------------------------
Usage Information Version Description 8.2.1.0 Introduced on the E-Series ExaScale. 7.4.1.0 Introduced on the E-Series TeraScale. When you configure trust IPv6 diffserv, matched bytes/packets counters are not incremented in the show qos statistics command. Trust diffserv (IPv4) can co-exist with trust ipv6-diffserv in an Input Policy Map.
28 Intermediate System to Intermediate System (ISIS) The intermediate system to intermediate system (IS-IS) protocol for IPv4 and IPv6 is supported on the S3048–ON platform. IS-IS is an interior gateway protocol that uses a shortest-path-first algorithm. IS-IS facilitates the communication between open systems, supporting routers passing both IP and OSI traffic. A router is considered an intermediate system. Networks are partitioned into manageable routing domains, called areas.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. To perform protocol-support consistency checks on hello packets, use this command. The adjacency-check is enabled by default. If a BFD session goes down indicating that IPv4 or IPv6 connectivity to its neighbor is lost, it does not imply that the adjacency is lost altogether. The hello adjacency runs over Layer 2, and does not require IP connectivity.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Version 6.3.1.0 Introduced You cannot disable leaking from Level 1 to Level 2. Also, you cannot enable leaking from Level 2 to Level 1. However, you can regulate the rate flow from one level to another using an IP Prefix list. If you do not configure the IP Prefix list, all Level 1 routes are leaked.
Usage Information To prevent the link state database from receiving incorrect routing information from unauthorized routers, use the area-password command on routers within an area. The configured password injects into Level 1 LSPs, CSNPs, and PSNPs. Related Commands • domain-password — allows you to set the authentication password for a routing domain. • isis password — allows you to configure an authentication password for an interface.
* Enter the keyword * to clear all IS-IS information and restart the IS-IS process. This command removes IS-IS neighbor information and IS-IS LSP database information and the full SPF calculation is done. database Clears IS-IS LSP database information. traffic Clears IS-IS counters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.11.1 Introduced on the Z9000. Usage Information To configure a shortcut name that you can use instead of entering a long string of numbers associated with an NSAP address, use this command. Related Commands hostname dynamic — enables dynamic learning of host names from routers in the domain and allows the routers to advertise the host names in LSPs. debug isis Enable debugging for all IS-IS operations.
To turn off debugging, use the no debug isis [vrf vrf-name]adj-packets [interface] command. Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to enable the debug information on IS-IS for an adjacency tied to that VRF. This command displays the IIH related debug details. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.
debug isis update-packets Enable debugging on link state PDUs (LSPs) that a router detects. Syntax debug isis [vrf vrf-name] update-packets [interface] To turn off debugging, use the no debug isis update-packets [interface] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable the debugging information on IS-IS. This information contains updates from neighbors tied to the VRF that you specify.
Parameters Defaults always (OPTIONAL) Enter the keyword always to have the default route always advertised. metric metric (OPTIONAL) Enter the keyword metric then a number to assign to the route. The range is from 0 to 16777215. route-map mapname (OPTIONAL) A default route the routing process generates if the route map is satisfied. Not configured. Command Modes Command History • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
description Enter a description of the IS-IS routing protocol. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Defaults none Command Modes ROUTER ISIS Command History Related Commands Enter a description to identify the IS-IS protocol (80 characters maximum). Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.5.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Added IPv6 ISIS support. 6.3.1.0 Introduced. When you execute this command, IS-IS does not download the route to the routing table if the same route was redistributed into IS-IS routing protocol on the same router. domain-password Set the authentication password for a routing domain. Syntax domain-password [hmac-md5 | encryption-type] password To disable the password, use the no domain-password command.
graceful-restart ietf Enable graceful restart on an IS-IS router. Syntax graceful-restart ietf To return to the default, use the no graceful-restart ietf command. Parameters ietf Enter ietf to enable graceful restart on the IS-IS router. Defaults Graceful restart disabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults 5 minutes Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart t3 — configures the overall wait time before graceful restart completes. graceful-restart t1 Set the graceful restart wait time before unacknowledged restart requests are generated.
graceful-restart t2 Configure the wait time for the graceful restart timer T2 that a restarting router uses as the wait time for each database to synchronize. Syntax graceful-restart t2 {level-1 | level-2} seconds To return to the default, use the no graceful-restart t2 command. Parameters level-1, level-2 Enter the keywords level-1 or level-2 to identify the database instance type to which the wait interval applies. seconds Enter the gracefule-restart t2 time in seconds.
Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
ignore-lsp-errors Ignore LSPs with bad checksums instead of purging those LSPs. Syntax ignore-lsp-errors To return to the default values, use the no ignore-lsp-errors command. Defaults In IS-IS, the default deletes LSPs with internal checksum errors (no ignore-lsp-errors). Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced. To assign a network entity title to enable IS-IS, use the net command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. Configure a network entity title (the net command) to specify the area address and the router system ID. To establish adjacencies and establish dynamic routing, enable routing on one or more interfaces. You can configure only one IS-IS routing process to perform Level 2 routing.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Because the default establishes Level 1 and Level 2 adjacencies, you do not need to configure this command. Routers in an IS-IS system must be configured as a Level 1-only, Level 1-2, or Level 2-only system.
Usage Information The default values of this command are typically satisfactory transmission times for a specific interface on a designated intermediate system. To maintain database synchronization, the designated routers send CSNPs. You can configure Level 1 and Level 2 CSNP intervals independently. isis hello-interval Specify the length of time between hello packets sent.
isis hello-multiplier Specify the number of IS-IS hello packets a neighbor must miss before the router declares the adjacency down. Syntax isis hello-multiplier multiplier [level-1 | level-2] To return to the default values, use the no isis hello-multiplier [multiplier] [level-1 | level-2] command. Parameters multiplier Specifies an integer that sets the multiplier for the hello holding time. Never configure a hello-multiplier lower than the default (3). The range is from 3 to 1000. The default is 3.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. Dell Networking recommends configuring metrics on all interfaces. Without configuring this command, the IS-IS metrics are similar to hop-count metrics. isis metric Assign a metric to an interface.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Dell Networking recommends configuring metrics on all interfaces. Without configuring this command, the IS-IS metrics are similar to hop-count metrics.
To delete a password, use the no isis password [password] [level-1 | level-2] command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES. hmac-md5 (OPTIONAL) Enter the keywords hmac-md5 to encrypt the password using MD5. password Assign the interface authentication password. level-1 (OPTIONAL) Independently configures the authentication password for Level 1. The router acts as a station router for Level 1 routing. This setting is the default.
To return to the default values, use the no isis priority [value] [level-1 | level-2] command. Parameters value This value sets the router priority. The higher the value, the higher the priority. The range is from 0 to 127. The default is 64. level-1 (OPTIONAL) Specify the priority for Level 1. This setting is the default. level-2 (OPTIONAL) Specify the priority for Level 2. Defaults value = 64; level-1 (if not otherwise specified).
level-2-only Allows a router to act as a Level 2 router. Defaults level-1-2 Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. This command allows you to monitor adjacency state changes, which are useful when you monitor large networks. Messages are logged in the system’s error message facility. lsp-gen-interval Set the minimum interval between successive generations of link-state packets (LSPs).
Usage Information Version Description 7.5.1.0 Added support for LSP Throttling Enhancement. LSP throttling slows down the frequency at which LSPs are generated during network instability. Even though throttling LSP generations slows down network convergence, no throttling can result in a network not functioning as expected. If network topology is unstable, throttling slows down the scheduling of LSP generations until the topology regains its stability.
Usage Information The link MTU and the LSP MTU size must be the same. Because each device can generate a maximum of 255 LSPs, consider carefully whether you use the lspmtu command. lsp-refresh-interval Set the link state PDU (LSP) refresh interval. LSPs must be refreshed before they expire. When the LSPs are not refreshed after a refresh interval, they are kept in a database until their max-lsp-lifetime reaches zero and then LSPs is purged.
max-area-addresses Configure manual area addresses. Syntax max-area-addresses number To return to the default values, use the no max-area-addresses command. Parameters number Set the maximum number of manual area addresses. The range is from 3 to 6. The default is 3. Defaults 3 addresses Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Added support for multi-topology ISIS. 6.3.1.0 Introduced. metric-style To generate and accept old-style, new-style, or both styles of type, length, and values (TLV), configure a router.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. If you enter the metric-style wide command, the Dell Networking OS generates and accepts only new-style TLVs. The router uses less memory and other resources rather than generating both old-style and new-style TLVs. The new-style TLVs have wider metric fields than old-style TLVs. When wide transition is configured, narrow metric is sent for the narrow metric TLV and the actual wide metric is sent in wide metric TLV.
net To configure an IS-IS network entity title (NET) for a routing process, use this mandatory command. If you did not configure a NET, the IS-IS process does not start. Syntax net network-entity-title To remove a net, use the no net network-entity-title command. Parameters network-entity-title Specify the area address and system ID for an IS-IS routing process. The first 1 to 13 bytes identify the area address. The next 6 bytes identify the system ID.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Defaults Command Modes Command History level-1-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level-1-2 routes. level-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 2 routes. This setting is the default. route-map mapname (OPTIONAL) If you do not enter the route-map argument, all routes are redistributed. If a map-name value is not specified, no routes are imported.
• distribute-list out — suppresses networks from being advertised in updates. This command filters redistributed routing information. redistribute bgp Redistribute routing information from a BGP process. Syntax redistribute bgp AS number [level-1| level-1-2 | level-2] [metric metricvalue] [metric-type {external| internal}] [route-map map-name] To return to the default values, use the no redistribute bgp command with the appropriate parameters.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.5.1.0 Added support for IPv6 ISIS. 6.3.1.0 Introduced. Usage Information BGP to IS-IS redistribution supports “match” options using route maps. You can set the metric value, level, and metric-type of redistributed routes by the redistribution command.
level-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 2 routes. This setting is the default. match {external | internal} (OPTIONAL) The command used for OSPF to route and redistribute into other routing domains. The values are route-map mapname • internal • external map-name is an identifier for a configured route map. The route map should filter imported routes from the source routing protocol to the current routing protocol.
router isis Allows you to enable the IS-IS routing protocol and to specify an IP IS-IS process. Syntax router isis [vrf vrf-name] [tag] To disable IS-IS routing, use the no router isis [tag] command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to enable the IS-IS routing protocol and to specify an IP IS-IS process on that VRF. tag (OPTIONAL) This is a unique name for a routing process. A null tag is assumed if the tag option is not specified.
set-overload-bit To set the overload bit in zeroth fragment of non-pseudonode LSPs on the router, configure the router. This setting prevents other routers from using it as an intermediate hop in their shortest path first (SPF) calculations. Syntax set-overload-bit To return to the default values, use the no set-overload-bit command. Defaults Not set. Command Modes Command History • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (RouterIsis) Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display IS-IS link state database corresponding to that VRF. NOTE: If you do not specify this option, the IS-IS link state database corresponding to the default VRF are displayed. Command Modes Command History level-1 (OPTIONAL) Displays the Level 1 IS-IS link-state database. level-2 (OPTIONAL) Displays the Level 2 IS-IS link-state database. local (OPTIONAL) Displays local link-state database information.
Field Description The designated router for a LAN creates and floods a pseudonode LSP and describes the attached systems. The last octet is the LSP number. An LSP is divided into multiple LSP fragments if there is more data than cannot fit in a single LSP. Each fragment has a unique LSP number. An * after the LSPID indicates that the system originates an LSP where this command was issued.
Metric: 10 IP 10.1.1.0 255.255.255.0 Hostname: ISIS IS-IS Level-2 Link State Database LSPID LSP Seq Num LSP Checksum LSP Holdtime ATT/P/OL ISIS.00-00 * 0x0000002D 0xB2CD 1075 0/0/0 Area Address: 49.0000.0001 NLPID: 0xCC 0x8E IP Address: 10.1.1.1 IPv6 Address: 1011::1 Topology: IPv4 (0x00) IPv6 (0x8002) Metric: 10 IS OSPF.00 Metric: 10 IS (MT-IPv6) OSPF.00 Metric: 10 IP 10.1.1.0 255.255.255.0 Metric: 10 IP 15.1.1.0 255.255.255.0 Metric: 20 IP 10.3.3.0 255.255.255.
Example Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series.
Example Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Dell#show isis hostname System Id Dynamic Name Static Name *F100.E120.0013 Force10 ISIS Dell# show isis interface Display detailed IS-IS interface status and configuration information.
Example Version Description 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Dell>show isis int GigabitEthernet 1/7 is up, line protocol is up MTU 1497, Encapsulation SAP Routing Protocol: IS-IS Circuit Type: Level-1-2 Interface Index 37847070, Local circuit ID 1 Level-1 Metric: 10, Priority: 64, Circuit ID: systest-3.
Command Modes Command History • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
MAC Address: 0000.0000.0000 Hold Time: 28 Link Local Address: fe80::201:e8ff:fe00:492c Topology: IPv4 IPv6 , Common (IPv4 IPv6 ) Adjacency being used for MTs: IPv4 IPv6 Dell# show isis protocol Display IS-IS routing information. Syntax Parameters Command Modes Command History show isis [vrf vrf-name] protocol vrf vrf-name • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS routing information corresponding to that VRF.
Accept narrow metrics: level-1-2 Generate wide metrics: none Accept wide metrics: none Multi Topology Routing is enabled in transition mode. Dell# show isis traffic This command allows you to display IS-IS traffic interface information. Syntax show isis [vrf vrf-name] traffic [interface] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS traffic interface information corresponding to that VRF.
Example Item Description Level-1/Level-2 Hellos (sent/rcvd) Displays the number of Hello packets sent and received. PTP Hellos (sent/ rcvd) Displays the number of point-to-point Hellos sent and received. Level-1/Level-2 LSPs sourced (new/refresh) Displays the number of new and refreshed LSPs. Level-1/Level-2 LSPs flooded (sent/rcvd) Displays the number of flooded LSPs sent and received. Level-1/Level-2 LSPs CSNPs (sent/ rcvd) Displays the number of CSNP LSPs sent and received.
spf-interval Specify the minimum interval between shortest path first (SPF) calculations. Syntax spf-interval [level-l | level-2] interval seconds [initial_wait_interval seconds [second_wait_interval seconds]] To restore default values, use the no spf-interval [level-l | level-2] interval seconds [initial_wait_interval seconds [second_wait_interval seconds]] command. Parameters Defaults level-l (OPTIONAL) Enter the keyword level-1 to apply the configuration to Level-1 SPF calculations.
SPF throttling slows down the frequency at which route calculations are performed during network instability. Even though throttling route calculations slows down network convergence, not throttling can result in a network not functioning as expected. If network topology is unstable, throttling slows down the scheduling of route calculations until the topology regains its stability.
29 Link Aggregation Control Protocol (LACP) This chapter contains commands for Dell Networks’s implementation of the link aggregation control protocol (LACP) for creating dynamic link aggregation groups (LAGs) — known as “port-channels” in the Dell Networking operating software. The LACP commands in this chapter are supported by Dell Networking OS on the S3048–ON platform.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. show lacp — displays the LACP configuration. debug lacp Debug LACP (configuration, events, and so on). Syntax debug lacp [config | events | pdu [interface-type [in | out]]] To disable LACP debugging, use the no [config | events | pdu [interface-type [in | out]]] command. Parameters config (OPTIONAL) Enter the keyword config to debug the LACP configuration.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. lacp long-timeout Configure a long timeout period (30 seconds) for an LACP session.
lacp port-priority To influence which ports will be put in Standby mode when there is a hardware limitation that prevents all compatible ports from aggregating, configure the port priority. Syntax lacp port-priority priority-value To return to the default setting, use the no lacp port-priority priority-value command. Parameters priority-value Enter the port-priority value. The higher the value number, the lower the priority. The range is from 1 to 65535. The default is 32768.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands show lacp — displays the LACP information. show interfaces port-channel — displays information on configured Port Channel groups. show lacp Display the LACP matrix. Syntax Parameters Defaults Command Modes Command History show lacp port-channel-number [sys-id | counters] port-channelnumber Enter a port-channel number. The range is from 1 to 128. sys-id (OPTIONAL) Enter the keywords sys-id and the value that identifies a system.
E-Aggregatable Link, F-Individual Link, G-IN_SYNC, H-OUT_OF_SYNC I-Collection enabled, J-Collection disabled, K-Distribution enabled LDistribution disabled, M-Partner Defaulted, N-Partner Non-defaulted, O-Receiver is in expired state, P-Receiver is not in expired state Port Gi 1/6 is enabled, LACP is Actor Admin: State ACEHJLMP Oper: State ACEGIKNP Partner Admin: State BDFHJLMP Oper: State BCEGIKNP Dell# Example (Sys-id) enabled and mode is lacp Key 1 Priority 128 Key 1 Priority 128 Key 0 Priority 0 Key 1
30 Layer 2 This chapter describes commands to configure Layer 2 features. This chapter contains the following sections: • MAC Addressing Commands • Virtual LAN (VLAN) Commands • Far-End Failure Detection (FEFD) The VLAN commands are supported on all the S3048–ON platform. MAC Addressing Commands The following commands are related to configuring, managing, and viewing MAC addresses. clear mac-address-table Clear the MAC address table of all MAC address learned dynamically.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support for sticky MAC addresses. 8.3.11.
Related Commands Version Description 8.3.1.0 On the E-Series, available in INTERFACE VLAN context, reduced the minimum aging time in the INTERFACE VLAN context from 10 seconds to 1 second. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. mac learning-limit — sets the MAC address learning limits for a selected interface. show mac-address-table aging-time — displays the MAC aging time.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048–ON. 9.7(0.0) Introduced on the S6000–ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.1(0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. For details about using this command, refer to the “NIC Teaming” section of the Layer 2 chapter in the Dell Networking OS Configuration Guide.
Usage Information Version Description 8.3.12.0 Deprecated the no-station-move command (replaced by the maclearning-limit mac-address-sticky command). 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the vlan option on the E-Series. 8.2.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added the station-move option. 6.5.1.0 Added support for MAC Learning-Limit on the LAG. This command and its options are supported on physical interfaces, static LAGs, LACP LAGs, and VLANs.
Defaults none Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. Usage Information If you configure mac-learn-limit and the sticky MAC feature is enabled, dynamically learned MAC addresses are converted to sticky for that port. Any new MAC address that is learned also becomes sticky for that port. Related Commands show mac learning-limit — displays the details of the mac learning-limit.
Version Description 7.8.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. Usage Information This command is supported on physical interfaces, static LAGs, and LACP LAGs. Related Commands show mac learning-limit — displays details of the mac learning-limit. mac learning-limit reset Reset the MAC address learning-limit error-disabled state. Syntax mac learning-limit reset Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
port-set port-pipe (REQUIRED) Enter the keywords port-set then a Port-Pipe number to select the Port-Pipe for which to gather information. count (REQUIRED) Enter the keyword count to display CAM usage by interface type. interface interface (OPTIONAL) Enter the keyword interface then the interface type, slot and port information: vlan vlan-id Command Modes Command History • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number.
Command Modes Command History dynamic (OPTIONAL) Enter the keyword dynamic to display only those MAC addresses the switch dynamically learns. interface interface (OPTIONAL) Enter the keyword interface then the interface type, slot and port information: • For a port channel interface, enter the keywords port-channel then a number. • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
112 113 114 115 116 117 Dell# 0 0 0 0 0 0 0 0 0 0 0 0 00:01:e8:0d:b7:62 00:01:e8:0d:b7:61 00:01:e8:0d:b7:60 00:01:e8:0d:b7:5f 00:01:e8:0d:b7:5e 00:01:e8:0d:b7:5d SYSTEM_STATIC SYSTEM_STATIC SYSTEM_STATIC SYSTEM_STATIC SYSTEM_STATIC SYSTEM_STATIC DROP DROP DROP DROP DROP DROP show mac-address-table Display the MAC address table.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.
Column Heading Description Mac Address Displays the MAC address in nn:nn:nn:nn:nn:nn format. Type Lists whether the MAC address was manually configured (Static), learned (Dynamic), or associated with a specific port (Sticky). An (N) indicates that the specified MAC address has been learnt by a neighbor and is synced to the node. Interface Displays the interface type and slot/port information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 8.3.19.0 Introduced on the S4820T. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. pre-6.2.1.
• Command Modes Command History • EXEC • EXEC Privilege For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
default vlan-id Specify a VLAN as the Default VLAN. Syntax default vlan-id vlan-id To remove the default VLAN status from a VLAN and VLAN 1 does not exist, use the no default vlanid vlan-id syntax. Parameters vlan-id Enter the VLAN ID number of the VLAN to become the new Default VLAN. The range is from 1 to 4094. The default is 1. Defaults The Default VLAN is VLAN 1. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description pre-6.2.1.1 Introduced on the E-Series. Usage Information To display information about a named VLAN, enter the show vlan command with the name parameter or the show interfaces description command. Related Commands interface vlan — configures a VLAN. show vlan — displays the current VLAN configurations on the switch. show config Display the current configuration of the selected VLAN.
Parameters Command Modes Command History brief (OPTIONAL) Enter the keyword brief to display the following information: • VLAN ID • VLAN name (left blank if none is configured) • Spanning Tree Group ID • MAC address aging time • IP address id vlan-id (OPTIONAL) Enter the keyword id then a number from 1 to 4094. Only information on the VLAN specified is displayed. name vlan-name (OPTIONAL) Enter the keyword name then the name configured for the VLAN.
Column Heading Description • NUM Displays existing VLAN IDs. Status Displays the word Inactive for inactive VLANs and the word Active for active VLANs.
Example (VLAN ID) P 100 Active T Po1(Gi 1/1) C 101 I 102 Dell# Inactive T Gi 1/3 Inactive T Gi 1/4 T Gi 1/2 Dell# show vlan id 40 Codes: Q: U x G - * - Default VLAN, G - GVRP VLANs Untagged, T - Tagged Dot1x untagged, X - Dot1x tagged GVRP tagged, M - Vlan-stack NUM 40 Status Description Q Ports Active M Gi 13/47 Dell#show vlan id 41 Codes: Q: U x G - * - Default VLAN, G - GVRP VLANs Untagged, T - Tagged Dot1x untagged, X - Dot1x tagged GVRP tagged, M - Vlan-stack NUM 41 Status Description Q Po
Related Commands vlan-stack compatible — enables the Stackable VLAN feature on the selected VLAN. interface vlan — configures a VLAN. tagged Add a Layer 2 interface to a VLAN as a tagged interface. Syntax tagged interface To remove a tagged interface from a VLAN, use the no tagged interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Tagged interfaces can belong to multiple VLANs, while untagged interfaces can only belong to one VLAN at a time. Related Commands interface vlan — configures a VLAN. untagged — specifies which interfaces in a VLAN are untagged. track ip Track the Layer 3 operational state of a Layer 3 VLAN, using a subset of the VLAN member interfaces. Syntax track ip interface To remove the tracking feature from the VLAN, use the no track ip interface command.
Usage Information When this command is configured, the VLAN is operationally UP if any of the interfaces specified in the track ip command are operationally UP, and the VLAN is operationally DOWN if none of the tracking interfaces are operationally UP. If the track ip command is not configured, the VLAN's Layer 3 operational state depends on all the members of the VLAN. The Layer 2 state of the VLAN, and hence the Layer 2 traffic, is not affected by the track ip command configuration.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Untagged interfaces can only belong to one VLAN. In the Default VLAN, you cannot use the no untagged interface command. To remove an untagged interface from all VLANs, including the Default VLAN, enter INTERFACE mode and use the no switchport command. Related Commands interface vlan — configures a VLAN.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.
Usage Information Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. When you enter no fefd for an interface and fefd-global, FEFD is enabled on the interface because the no fefd command is not retained in the configuration file.
Related Commands • fefd reset — enables FEFD globally on the system. • fefd mode — changes FEFD mode on an interface. fefd interval Set an interval between control packets. Syntax fefd interval seconds To return to the default value, use the no fefd interval command. Parameters seconds Enter a number as the time between FEFD control packets. The range is from 3 to 300 seconds. The default is 15 seconds.
aggressive (OPTIONAL) Enter the keyword aggressive to change the link state to “errordisabled” when a far-end failure the software detects on that interface. When an interface is placed in “error-disabled” state, enter the fefd reset command to reset the interface state. Defaults normal Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. fefd-global interval Configure an interval between FEFD control packets. Syntax fefd-global interval seconds To return to the default value, use the no fefd-global interval command.
fefd-global Enable FEFD globally on the system. Syntax fefd-global [interval seconds][mode {normal | aggressive}] To disable FEFD globally, use the no fefd-global [mode {normal | aggressive}] command. Parameters interval seconds Enter the keyword interval followed by the number of seconds to wait between FEFD control packets. Range is from 3 to 300 seconds. Default is 15 seconds.
show fefd View FEFD status globally or on a specific interface. Syntax show fefd [interface] Parameters Command Modes Command History interface • EXEC • EXEC Privilege (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. This guide is platform-specific.
Field Example Description • locally disabled (interface contains the fefd reset command in its configuration). • Admin Shutdown (interface is disabled with the shutdown command). Dell#show fefd FEFD is globally 'ON', interval is 10 seconds, mode is 'Aggressive'.
31 Link Layer Discovery Protocol (LLDP) The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the adjacent stations on an IEEE 802 LAN. This chapter contains the following sections: • LLPD Commands • LLDP-MED Commands LLDP facilitates multi-vendor interoperability by using standard management tools to discover and make available a physical topology for network management.
Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. advertise management-tlv Advertise management TLVs (Type, Length, Value).
Usage Information Version Description 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. The command options management-address,system-capabilities, system-description, and system-name can be invoked individually or together, in any sequence. advertise management-tlv (Interface) Advertise management type, length, values (TLVs) to the specified interface.
Parameters interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Command History Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. protocol lldp (Configuration) — enables LLDP globally. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. hello Configure the rate at which the LLDP control packets are sent to its peer. Syntax hello seconds To revert to the default, use the no hello seconds command.
management-interface Enable and configure LLDP protocol parameters on the management interface. Syntax management-interface To remove LLDP configuration on a management interface, use the no management-interface command. Command Modes LLDP (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. protocol lldp (Configuration) — enables LLDP globally. show lldp neighbors — displays the LLDP neighbors. multiplier Set the number of consecutive misses before LLDP declares the interface dead.
protocol lldp (Configuration) Enable the LLDP globally on the switch. Syntax protocol lldp To disable LLDP globally on the chassis, use the no protocol lldp command. Defaults Enabled. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. Before LLDP can be configured on an interface, it must be enabled globally from CONFIGURATION mode.
Version Description 9.1.(0.0) Modified output of detail parameter to display remote management IP addresses. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. Usage Information Omitting the keyword detail displays only the remote chassis ID, Port ID, and Dead Interval.
Number of Table Deletes : Number of Table Drops : Number of Table Age Outs : Dell# 200 0 400 show management-interface Display LLDP management interface configuration information. Syntax show management-interface Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Example Dell#show running-config lldp ! protocol lldp advertise dot1-tlv port-protocol-vlan-id port-vlan-id advertise dot3-tlv max-frame-size advertise management-tlv system-capabilities system-description hello 15 multiplier 3 no disable Dell# LLDP-MED Commands The following are the LLDP-MED (Media Endpoint Discovery) commands. Dell Networking OS LLDP-MED commands are an extension of the set of LLDP TLV advertisement commands. The C-Series and SSeries support all commands.
priority-tagged number Enter the keywords priority-tagged followed the Layer 2 priority. The range is from 0 to 7. Defaults Unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.
Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series and E-Series.
Version Description 7.6.1.0 Introduced on the C-Series. Usage Information Advertise the Extended Power via MDI on all ports that are connected to an 802.3af powered, LLDP-MED endpoint device. Related Commands debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med softphone-voice To advertise softphone to enable IP telephony on a computer so that the computer can be used as a phone, configure the system.
show lldp neighbors — displays the LLDP neighbors. advertise med streaming-video To advertise streaming video services for broadcast or multicast-based video, configure the system. This command does not include video applications that rely on TCP buffering. Syntax advertise med streaming-video {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med streaming-video {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command.
advertise med video-conferencing To advertise dedicated video conferencing and other similar appliances that support real-time interactive video, configure the system. Syntax advertise med video-conferencing {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med video-conferencing {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094.
advertise med video-signaling To advertise video control packets that use a separate network policy than video data, configure the system. Syntax advertise med video-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med video-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094.
To return to the default, use the no advertise med voice {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094. layer2_priority Enter the Layer 2 priority (C-Series and E-Series only). The range is from 0 to 7. DSCP_value Enter the DSCP value (C-Series and E-Series only). The range is from 0 to 63. priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7.
priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.
32 Microsoft Network Load Balancing Network Load Balancing (NLB) is a clustering functionality that is implemented by Microsoft on Windows 2000 Server and Windows Server 2003 operating systems. Microsoft NLB clustering allows multiple servers running Microsoft Windows to be represented by one MAC and one IP address to provide transparent failover and load-balancing.
vlan vlan-id Enter the keyword vlan then a VLAN ID number from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION Command History The following is a list of the Dell Networking OS version history for this command. Example (Multicast) Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.3(0.0) Added support for multicast MAC address on the MXL platform.
33 Multicast Source Discovery Protocol (MSDP) Multicast source discovery protocol (MSDP) connects multiple PIM Sparse-Mode (PIM-SM) domains together. MSDP peers connect using TCP port 639. Peers send keepalives every 60 seconds. A peer connection is reset after 75 seconds if no MSDP packets are received. MSDP connections are parallel with MBGP connections. The Dell Networking operating system supports MSDP commands on the S3048–ON platform.
clear ip msdp sa-cache Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. Syntax Parameters clear ip msdp sa-cache [group-address | rejected-sa | local] group-address Enter the group IP address in dotted decimal format (A.B.C.D.).
peer-address Enter the IP address of the MSDP peer. Defaults Without any options, this command clears the entire source-active cache. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced ip msdp cache-rejected-sa Enable an MSDP cache for the rejected source-active entries.
ip msdp default-peer Define a default peer from which to accept all source-active (SA) messages. Syntax ip msdp default-peer peer address [list name] To remove the default peer, use the no ip msdp default-peer {peer address} list name command. Parameters peer address Enter the peer address in a dotted decimal format (A.B.C.D.) list name Enter the keywords list name and specify a standard access list that contains the RP address that should be treated as the default peer.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced An MSDP mesh group is a mechanism for reducing SA flooding, typically in an intra-domain setting. When some subset of a domain’s MSDP speakers are fully meshed, they can be configured into a mesh-group.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 6.2.1.1 Introduced ip msdp peer Configure an MSDP peer. Syntax ip msdp peer peer address [connect-source] [description] [sa-limit number] To remove the MSDP peer, use the no ip msdp peer peer address [connect-source interface] [description name] [sa-limit number] command.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.5.1.0 Added option for SA upper limit and the description option. 6.2.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced Modifications to the ACL do not have an immediate effect on the sa-cache.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the E-Series. ip msdp sa-limit Configure the upper limit of source-active (SA) entries in SA-cache. Syntax ip msdp sa-limit number To return to the default, use the no ip msdp sa-limit number command. Parameters number Enter the maximum number of SA entries in SA-cache. The range is from 1 to 500000.
Related Commands ip msdp peer — configures the MSDP peer. clear ip msdp peer — clears the MSDP peer. show ip msdp — displays the MSDP information. ip msdp shutdown Administratively shut down a configured MSDP peer. Syntax Parameters ip msdp shutdown {peer address} peer address Enter the peer address in a dotted decimal format (A.B.C.D.). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced Dell#show ip msdp peer 100.1.1.1 Peer Addr: 100.1.1.1 Local Addr: 100.1.1.
Example 928 Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. 7.4.1.0 Introduced. Dell#show ip msdp sa-cache rejected-sa MSDP Rejected SA Cache 200 rejected SAs UpTime GroupAddr SourceAddr RPAddr 00:00:13 225.1.2.1 10.1.1.3 110.1.1.1 00:00:13 225.1.2.2 10.1.1.4 110.1.1.1 00:00:13 225.1.2.3 10.1.1.3 110.1.1.1 00:00:13 225.1.2.4 10.1.1.4 110.1.1.1 00:00:13 225.1.2.5 10.1.1.3 110.1.1.
34 Multiple Spanning Tree Protocol (MSTP) Multiple spanning tree protocol (MSTP), as implemented by the Dell Networking operating system, conforms to IEEE 802.1s. This command supports the Dell Networking S3048–ON platform. debug spanning-tree mstp Enable debugging of the multiple spanning tree protocol and view information on the protocol.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. protocol spanning-tree mstp — enters MULTIPLE SPANNING TREE mode. forward-delay The amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State. Syntax forward-delay seconds To return to the default setting, use the no forward-delay command.
hello-time Set the time interval between generation of MSTB bridge protocol data units (BPDUs). Syntax hello-time seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10. The default is 2 seconds. Defaults 2 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40. The default is 20 seconds. Defaults 20 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Valid priority values are: 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, and 61440. All other values are rejected. Defaults default bridge-priority is 32768. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. Usage Information For two MSTP switches to be within the same MSTP region, the switches must share the same region name (including matching case).
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. MSTP is not enabled when you enter MULTIPLE SPANNING TREE mode. To enable MSTP globally on the switch, enter the no disable command while in MULTIPLE SPANNING TREE mode. For more information about the multiple spanning tree protocol, refer to the Dell Networking OS Configuration Guide.
Version Description 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Usage Information For two MSTP switches to be within the same MST region, the switches must share the same revision number. Related Commands msti — maps the VLAN(s) to an MST instance. name — assigns the region name to the MST region. show config View the current configuration for the mode. Only non-default values are shown.
show spanning-tree mst configuration View the multiple spanning tree configuration. Syntax show spanning-tree mst configuration Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
guard Command Modes Command History • EXEC • EXEC Privilege (Optional) Enter the keyword guard to display the type of guard enabled on an MSTP interface and the current port state. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Port path cost 0, Port priority 128, Port Identifier 128.89 Designated root has priority 16384, address 0001.e800.0a:5c Designated bridge has priority 16384, address 0001.e800.0a:5c Designated port id is 128.89, designated path cost Number of transitions to forwarding state 3 BPDU (Mrecords): sent 7, received 1103 The port is not in the portfast mode Example (EDS and LBK) The bold line shows the loopback BPDU inconsistency (LBK_INC).
Example (Guard) Field Description Guard Type Type of STP guard configured (Root, Loop, or BPDU guard). Dell#show spanning-tree msti 5 guard Interface Name Instance Sts Guard type -----------------------------------Gi 1/1 5 INCON(Root) Rootguard Gi 1/2 5 FWD Loopguard Gi 1/3 5 EDS(Shut) Bpduguard spanning-tree Enable the multiple spanning tree protocol on the interface. Syntax spanning-tree To disable the multiple spanning tree protocol on the interface, use the no spanning-tree command.
spanning-tree msti Configure multiple spanning tree instance cost and priority for an interface. Syntax spanning-tree msti instance {cost cost | priority priority} Parameters msti instance Enter the keyword msti and the MST instance number. The range is from zero (0) to 63. cost cost (OPTIONAL) Enter the keyword cost then the port cost value. The range is from 1 to 200000.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
35 Multicast The multicast commands are supported by Dell Networking operating system (OS) on all S3048–ON platform. This chapter contains the following sections: • IPv4 Multicast Commands IPv4 Multicast Commands The following section contains the IPv4 multicast commands. clear ip mroute Clear learned multicast routes on the multicast forwarding table. To clear the protocol-independent multicast (PIM) tree information base, use the clear ip pim tib command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. E-Series legacy command Related Commands show ip pim tib — shows the PIM tree information base. ip mroute Assign a static mroute.
distance (OPTIONAL) Enter a number as the distance metric assigned to the mroute. The range is from 0 to 255. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. This feature allows you to limit the number of multicast entries on the system. This number is the total of all the multicast entries on all line cards in the system. On each line card, the multicast module only installs the maximum number of entries, depending on the configured CAM profile. To store multicast routes, use the IN-L3-McastFib CAM partition.
show ip mroute View the multicast routing table. Syntax show ip mroute [vrf vrf-name] [static | group-address [source-address] | count | snooping [vlan vlan-idIntroduced on the S6000-ON.] [group-address [source-address]] | summary | vlt [group-address [source-address] | count] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
Version Description 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for keyword vlt to the Z9000, S4810, and S4820T. 8.4.1.1 Support for the keyword snooping and the optional vlan vlan-id, groupaddress, and source-address parameters were added on E-Series ExaScale. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Example (Static) Dell#show ip mroute static Mroute: 23.
Example Field Description (S, G) Displays the forwarding entry in the multicast route table. uptime Displays the amount of time the entry has been in the multicast forwarding table. Incoming interface Displays the reverse path forwarding (RPF) information towards the source for (S,G) entries and the RP for (*,G) entries.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. E-Series legacy command Usage Information Network administrators use static mroutes to control the reach-ability of the multicast sources. If a PIMregistered multicast source is reachable using static mroute as well as unicast route, the distance of each route is examined and the route with shorter distance is the one the PIM selects for reach-ability.
36 Neighbor Discovery Protocol (NDP) The neighbor discovery protocol for IPv6 is defined in RFC 2461 as part of the Stateless Address Autoconfiguration protocol. It replaces the Address Resolution Protocol used with IPv4.
Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
hardware_address • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a tunnel interface, enter the keyword tunnel then the tunnel interface number. The range is from 1 to 16383. Enter a 48-bit hardware MAC address in nn:nn:nn:nn:nn:nn format. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(1.0) Introduced on the Z9500. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810.
count value • For a port channel interface, enter the keywords port-channel then a number. • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. Enter the keyword count then the number of debug outputs. The range is from 1 to 65534. The default is infinity.
• ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. hop-limit Enable the verification of the advertised hop count limit. If this command is not configured, the verification process is bypassed. Syntax hop-limit {maximum | minimum limit} To reset the hop count limit, use the no hop-limit {maximum | minimum limit} command. Parameters maximum limit Enter the keyword maximum then the hop limit value. The range is from 0 to 254.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. show ipv6 nd ra-guard policy — Displays the configuration applied on all the RA guard policies or a specific RA guard policy. ipv6 nd ra-guard enable Allow you to configure the RA guard related commands.
Related Commands ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. managed-config-flag Set the managed address configuration flag. Syntax managed-config-flag {on | off} To clear the flag, use the no managed-config-flag {on | off} command. Parameters on Enter the keyword on to set the managed-config-flag value as ON. off Enter the keyword off to set the managed-config flag value as OFF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches.
To reset the other configuration parameter, use the no other-config-flag {on | off} command. Parameters on Enter the keyword on to set the other-config-flag value as ON. off Enter the keyword off to set the other-config flag value as OFF. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
• ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode. retrans-time Enable the verification of the configured retransmission timer value in the received RA packets. Syntax retrans—timer value To reset the advertised retransmission interval, use the no retrans-timervalue command. Parameters value Enter the advertised retransmission time interval in milliseconds. The range is from 100 to 4,294,967,295 milliseconds.
Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. router-preference maximum Enable the verification of the advertised default router preference (DRP) value. The preference value is lower than or equal to the specified limit. If this command is not configured, the verification process is bypassed.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches.
Example Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. Dell#show ipv6 nd ra-guard policy test ipv6 nd ra-guard policy test device-role router hop-limit maximum 1 match ra ipv6-access-list access other-config-flag on router-preference maximum medium trusted-port Interfaces : Gi 1/1 Dell# Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands.
Usage Information Related Commands 966 Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. Use this command to disable all the RA guard policies. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode.
37 Object Tracking Object Tracking supports IPv4 and IPv6, and is available on the Dell Networking, C-Series, E-Series, S-Series, and S4810 platforms. Object tracking allows you to define objects of interest, monitor their state, and report to a client when a change in an object’s state occurs.
Example Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Dell#debug track all 04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface GigabitEthernet 1/2 line-protocol DOWN 04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN delay Configure the time delay used before communicating a change in the status of a tracked object to clients. Syntax delay {[up seconds] [down seconds]} To return to the default setting, use the no delay command.
description Enter a description of a tracked object. Syntax description {text} To remove the description, use the no description {text} command. Parameters text Enter a description to identify a tracked object (80 characters maximum). Defaults none Command Modes OBJECT TRACKING (conf_track_object-id) Command History Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.
threshold metric up 200 track 3 ipv6 route 2050::/64 reachability track 4 interface GigabitEthernet 1/2 ip routing track 5 ip route 192.168.0.0/24 reachability vrf red track resolution ip route isis 20 track resolution ip route ospf 10 Example (Object-id) Dell#show running-config track 300 track 300 ip route 10.0.0.
Usage Information Example Version Description 8.4.1.0 Introduced. The following describes the show track command shown in the Example below. Output Description Track object-id Displays the number of the tracked object. Interface type slot/ port, IP route ipaddress, IPv6 route ipv6-address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked.
Example (Brief) Related Commands Dell>show track brief ResId Resource Parameter State LastChange 1 IP route reachability 10.16.0.0/16 Up 00:01:08 2 Interface line-protocol Ethernet0/2 Down 00:05:00 3 Interface ip routing VLAN100 Up 01:10:05 • show running-config track – displays configuration information about tracked objects. • track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface.
• If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in the routing table, the state of a route is DOWN. Configure the UP and DOWN thresholds for each tracked route with the threshold metric command. The default UP threshold is 254; the default DOWN threshold is 255. The notification of a change in the state of a tracked object is sent when a metric value crosses a configured threshold.
Related Commands • The status of the IPv4 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address. • The Layer 3 status of an IPv4 interface goes DOWN when its Layer 2 status goes down (for a Layer 3 VLAN, all VLAN ports must be down) or the IP address is removed from the routing table. • show track – displays information about tracked objects, including configuration, current state, and clients which track the object.
• track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface. track ip host reachability Configure object tracking on the reachability of an IPv4 host. Syntax track object-id ip host host-ip-address/prefix-len reachability [vrf vrfname] To return to the default setting, use the no track object-id command. Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500.
Usage Information Version Description 8.4.1.0 Introduced. Use this command to create an object that tracks the UP and/or DOWN threshold of an IPv4 route metric. In order for a route’s metric to be tracked, the route must appear as an entry in the routing table. A tracked IPv4 route is considered to match an entry in the routing table only if the exact IPv4 address and prefix length match a table entry. For example, when configured as a tracked route, 10.0.0.
Command History Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the reachability of an IPv4 route. In order for a route’s reachability to be tracked, the route must appear as an entry in the routing table.
Usage Information Version Description 8.4.1.0 Introduced. Use this command to configure the protocol-specific resolution value that converts the actual metric of an IPv4 route in the routing table to a scaled metric in the range 0 to 255. The UP/DOWN state of a tracked IPv4 route is determined by a user-configurable threshold (the threshold metric command) for the route’s metric in the routing table.
• Command History Usage Information Example EXEC Privilege Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. The following describes the show track ipv6 route command shown in the Example below. Output Description Track object-id Displays the number of the tracked object.
Example (Brief) Ouput Description Last Change Time since the last change in the state of the tracked object. Dell#show track ipv6 route brief ResId Resource Parameter State LastChange 2 IPv6 route metric threshold 2040::/64 Up 00:02:36 3 IPv6 route reachability 2050::/64 Up 00:02:36 Related Commands • show running-config track – displays configuration information about tracked objects.
Usage Information Related Commands Use this command to create an object that tracks the routing state of an IPv6 Layer 3 interface: • The status of the IPv6 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address. • The Layer 3 status of an IPv6 interface goes DOWN when its Layer 2 status goes down (for a Layer 3 VLAN, all VLAN ports must be down) or the IP address is removed from the routing table.
• If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in the routing table, the state of a route is DOWN. You configure the UP and DOWN thresholds for each tracked IPv6 route by using the threshold metric command. The default UP threshold is 254; the default DOWN threshold is 255. The notification of a change in the state of a tracked object is sent when a metric value crosses a configured threshold.
Related Commands • show track ipv6 route – displays information about tracked IPv6 routes, including configuration, current state, and clients which track the route. • track ipv6 route reachability – configures object tracking on the reachability of an IPv4 route. track resolution ipv6 route Configure the protocol-specific resolution value used to scale an IPv6 route metric.
• 984 Object Tracking track ipv6 route metric threshold – configures object tracking on the threshold of an IPv6 route metric.
38 Open Shortest Path First (OSPFv2 and OSPFv3) Open Shortest Path First version 2 for IPv4 is supported on platform. OSPF is an Interior Gateway Protocol (IGP), which means that it distributes routing information between routers in a single Autonomous System (AS). OSPF is also a link-state protocol in which all routers contain forwarding tables derived from information about their links to their neighbors.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. area range Summarize routes matching an address/mask at an area border router (ABR).
Version Description 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. Usage Information Only the routes within an area are summarized, and that summary is advertised to other areas by the ABR. External routes are not summarized. Related Commands area stub — creates a stub area. router ospf — enters ROUTER OSPF mode to configure an OSPF instance.
Version Description pre- 6.1.1.1 Introduced on the E-Series. Usage Information To configure all routers and access servers within a stub, use this command. Related Commands router ospf — enters ROUTER OSPF mode to configure an OSPF instance. auto-cost Specify how the OSPF interface cost is calculated based on the reference bandwidth method.
Parameters process-id Enter the OSPF Process ID to clear a specific process. If no Process ID is entered, all OSPF processes are cleared. process (OPTIONAL) Enter the keyword process to reset the OSPF process. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
neighbor router-id • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a VLAN, enter the keyword vlan then a number from 1 to 4094. (OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted decimal format (A.B.C.D.). Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
database-timer rate-limit (OPTIONAL) Enter the keywords database-timer rate-limit to display the LSA throttling timer information. This applies to the S4810 platform only. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 992 Version Description 9.8(0.
Field Description • Example 2 - MD5 authentication configured using the ip ospf message-digestkey command auk: If the ip ospf authentication-key command is configured, this field displays the key used. keyid: If the ip ospf message-digest-key command is configured, this field displays the MD5 key to: Displays the interface to which the packet is intended. dst: Displays the destination IP address. netmask: Displays the destination IP address mask.
Parameters always (OPTIONAL) Enter the keyword always to specify that default route information must always be advertised. metric metric-value (OPTIONAL) Enter the keyword metric then a number to configure a metric value for the route. The range is from 1 to 16777214. metric-type typevalue (OPTIONAL) Enter the keywords metric-type then an OSPF link state type of 1 or 2 for default routes.
Defaults Disabled. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. show ip ospf asbr — displays the VLAN configuration. distance Define an administrative distance for particular routes to a specific IP address.
Version Description pre- 6.1.1.1 Introduced on the E-Series. distance ospf Configure an OSPF distance metric for different types of routes. S3048–ON Syntax distance ospf [external dist3] [inter-area dist2] [intra-area dist1] To delete these settings, use the no distance ospf command. Parameters Defaults external dist3 (OPTIONAL) Enter the keyword external then a number to specify a distance for external type 5 and 7 routes. The range is from 1 to 255. The default is 110.
distribute-list in Apply a filter to incoming routing updates from OSPF to the routing table. S3048–ON Syntax distribute-list prefix-list-name in [interface] To delete a filter, use the no distribute-list prefix-list-name in [interface] command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For Port Channel groups, enter the keywords port-channel then a number.
distribute-list out To restrict certain routes destined for the local routing table after the SPF calculation, apply a filter. S3048–ON Syntax distribute-list prefix-list-name out [bgp | connected | isis | rip | static] To remove a filter, use the no distribute-list prefix-list-name out [bgp | connected | isis | rip | static] command. Parameters prefix-list-name Enter the name of a configured prefix list. bgp (OPTIONAL) Enter the keyword bgp to specify that BGP routes are distributed.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The distribute-list out command applies to routes autonomous system boundary routers (ASBRs) redistributes into OSPF. It can be applied to external type 2 and external type 1 routes, but not to intra-area and inter-area routes.
graceful-restart grace-period Specifies the time duration, in seconds, that the router’s neighbors continue to advertise the router as fully adjacent regardless of the synchronization state during a graceful restart. NOTE: This command enables OSPFv2 graceful restart globally by setting the grace period (in seconds) that an OSPFv2 router’s neighbors continues to advertise the router as adjacent during a graceful restart.
Parameters ip-address Enter the OSPF router-id, in IP address format, of the restart router that will not act as a helper during graceful restart. Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. graceful-restart role Specify the role for your OSPF router during graceful restart.
Version Description 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. ip ospf auth-change-wait-time OSPF provides a grace period while OSPF changes its interface authentication type. During the grace period, OSPF sends out packets with new and old authentication scheme until the grace period expires. S3048–ON Syntax ip ospf auth-change-wait-time seconds To return to the default, use the no ip ospf auth-change-wait-time command. Parameters seconds Enter the seconds.
key Enter an eight-character string. Strings longer than eight characters are truncated. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. If this command is not configured, cost is based on the auto-cost command. When you configure OSPF over multiple vendors, to ensure that all routers use the same cost, use the ip ospf cost command. Otherwise, OSPF routes improperly.
Version Description pre- 6.1.1.1 Introduced on the E-Series. Usage Information By default, the dead interval is four times the default hello-interval. Related Commands ip ospf hello-interval — sets the time interval between the hello packets. ip ospf hello-interval Specify the time interval between the hello packets sent on the interface. S3048–ON Syntax ip ospf hello-interval seconds To return to the default value, use the no ip ospf hello-interval command.
To delete a key, use the no ip ospf message-digest-key keyid command. Parameters keyid Enter a number as the key ID. The range is from 1 to 255. key Enter a continuous character string as the password. Defaults No MD5 authentication is configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
To return to the default, use the no ip ospf mtu-ignore command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. ip ospf priority To determine the designated router for the OSPF network, set the priority of the interface.
Use this command for interfaces connected to multi-access networks, not point-to-point networks. ip ospf retransmit-interval Set the retransmission time between lost link state advertisements (LSAs) for adjacencies belonging to the interface. S3048–ON Syntax ip ospf retransmit-interval seconds To return to the default values, use the no ip ospf retransmit-interval command. Parameters seconds Enter the number of seconds as the interval between retransmission. The range is from 1 to 3600.
Parameters seconds Enter the number of seconds as the interval between retransmission. The range is from 1 to 3600. The default is 1 second. This value must be greater than the transmission and propagation delays for the interface. Defaults 1 second Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. maximum-paths Enable the software to forward packets over multiple paths. S3048–ON Syntax maximum-paths number To disable packet forwarding over multiple paths, use the no maximum-paths command.
Version Description pre- 6.1.1.1 Introduced on the E-Series. network area Define which interfaces run OSPF and the OSPF area for those interfaces. S3048–ON Syntax network ip-address mask area area-id To disable an OSPF area, use the no network ip-address mask area area-id command. Parameters ip-address Specify a primary or secondary address in dotted decimal format. The primary address is required before adding the secondary address. mask Enter a network mask in /prefix format.
If you delete all the network area commands for Area 0, the show ip ospf command output does not list Area 0. passive-interface Suppress both receiving and sending routing updates on an interface. S3048–ON Syntax passive-interface {default | interface} To enable both the receiving and sending routing, use the no passive-interface interface command. To return all OSPF interfaces (current and future) to active, use the no passive-interface default command.
Usage Information Version Description 7.4.1.0 Modified to include the keyword default. pre- 6.1.1.1 Introduced on the E-Series. Although the passive interface does not send or receive routing updates, the network on that interface is still included in OSPF updates sent using other interfaces. The default keyword sets all interfaces as passive. You can then configure individual interfaces, where adjacencies are desired, using the no passive-interface interface command.
To disable redistribution, use the no redistribute {connected | isis | rip | static} command. Parameters connected Enter the keyword connected to specify that information from active routes on interfaces is redistributed. isis Enter the keyword isis to specify that ISO IS-IS information is redistributed. ospf Enter the keyword ospf to specify that information corresponding to OSPF is redistributes. rip Enter the keyword rip to specify that RIP routing information is redistributed.
Despite removing an OSPF process globally, the OSPF process is not completely removed from the BGP configuration. Related Commands default-information originate — generates a default route into the OSPF routing domain. redistribute bgp Redistribute BGP routing information throughout the OSPF instance.
Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the keyword default. pre- 6.1.1.1 Introduced on the E-Series. redistribute isis Redistribute IS-IS routing information throughout the OSPF instance.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. router-id To configure a fixed router ID, use this command. S3048–ON Syntax router-id ip-address To remove the fixed router ID, use the no router-id ip-address command.
Example Dell(conf)#router ospf 100 Dell(conf-router_ospf)#router-id 1.1.1.1 Changing router-id will bring down existing OSPF adjacency [y/n]: Dell(conf-router_ospf)#show config ! router ospf 100 router-id 1.1.1.1 Dell(conf-router_ospf)#no router-id Changing router-id will bring down existing OSPF adjacency [y/n]: Dell# router ospf To configure an OSPF instance, enter ROUTER OSPF mode. S3048–ON Syntax router ospf process-id To clear an OSPF instance, use the no router ospf process-id command.
show config Display the non-default values in the current OSPF configuration. S3048–ON Syntax show config Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added output for LSA throttling timers. 8.3.7.0 Introduced on the S4810. 7.9.1.0 Added support for VRF. 7.8.1.0 Added support of Multi-Process OSPF. 7.8.1.
show ip ospf interface — displays the OSPF interfaces configured. show ip ospf neighbor — displays the OSPF neighbors configured. show ip ospf asbr Display all autonomous system boundary router (ASBR) routers visible to OSPF. S3048–ON Syntax show ip ospf [process-id | vrf vrf-name] asbr Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Example Dell#show ip ospf 1asbr RouterID 3.3.3.3 1.1.1.1 Dell# Flags -/-/-/ E/-/-/ Cost Nexthop 2 10.0.0.2 0 0.0.0.0 Interface Area Gi 1/1 1 0 show ip ospf database Display all LSA information. If you do not enable OSPF on the switch, no output is generated. S3048–ON Syntax Parameters Command Modes Command History show ip ospf process-id [vrf vrf-name] database [database-summary] process-id Enter the OSPF Process ID to show a specific process.
Example Field Description Seq# Identifies the link state sequence number. This number allows you to identify old or duplicate link state advertisements. Checksum Displays the Fletcher checksum of an LSA’s complete contents. Link count Displays the number of interfaces for that router. Dell>show ip ospf 1 database OSPF Router with ID (11.1.2.1) (Process ID 1) Router (Area 0.0.0.0) Link ID ADV Router Age Seq# Checksum 11.1.2.1 11.1.2.1 673 0x80000005 0x707e 13.1.1.1 13.1.1.
adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the keywords adv-router and the ip-address to display only the LSA information about that router. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
Example Field Description Metric Displays the LSA metric. Dell#show ip ospf 100 database asbr-summary OSPF Router with ID (1.1.1.10) (Process ID 100) Summary Asbr (Area 0.0.0.0) LS age: 1437 Options: (No TOS-capability, No DC, E) LS type: Summary Asbr Link State ID: 103.1.50.1 Advertising Router: 1.1.1.10 LS Seq Number: 0x8000000f Checksum: 0x8221 Length: 28 Network Mask: /0 TOS: 0 Metric: 2 LS age: 473 Options: (No TOS-capability, No DC, E) LS type: Summary Asbr Link State ID: 104.1.50.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Field Description Forward Address Identifies the address of the forwarding router. Data traffic is forwarded to this router. If the forwarding address is 0.0.0.0, data traffic is forwarded to the originating router. External Route Tag Displays the 32-bit field attached to each external route. The OSPF protocol does not use this field, but you can use the field for external route management. Dell#show ip ospf 1 database external OSPF Router with ID (20.20.20.
adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router and the ip-address to display only the LSA information about that router. This guide is platform-specific.
Example Field Description Checksum Identifies the link state sequence number. This number enables you to identify old or duplicate LSAs. Length Displays the Fletcher checksum of an LSA’s complete contents. Network Mask Displays the length in bytes of the LSA. Attached Router Identifies the IP address of routers attached to the network. Dell#show ip ospf 1 data network OSPF Router with ID (20.20.20.5) (Process ID 1) Network (Area 0.0.0.
• adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router and the ip-address to display only the LSA information about that router. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example 1034 Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
OSPF Router with ID (3.3.3.3) (Process ID 1) Type-10 Opaque Link Area (Area 0) LS age: 1133 Options: (No TOS-capability, No DC, E) LS type: Type-10 Opaque Link Area Link State ID: 1.0.0.1 Advertising Router: 10.16.1.160 LS Seq Number: 0x80000416 Checksum: 0x376 Length: 28 Opaque Type: 1 Opaque ID: 1 Unable to display opaque data LS age: 833 Options: (No TOS-capability, No DC, E) LS type: Type-10 Opaque Link Area Link State ID: 1.0.0.2 Advertising Router: 10.16.1.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. show ip ospf database — displays OSPF database information.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. show ip ospf database — displays OSPF database information. show ip ospf database router Display the router (type 1) LSA information.
Usage Information Example Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database router command shown in the following example. Item Description LS Age Displays the LSA age. Options Displays the optional capabilities available on router.
Advertising Router: 1.1.1.10 LS Seq Number: 0x8000012f Checksum: 0x3357 Length: 144 AS Boundary Router Area Border Router Number of Links: 10 Link connected to: a Transit Network (Link ID) Designated Router address: 192.68.129.1 (Link Data) Router Interface address: 192.68.129.1 Number of TOS metric: 0 TOS 0 Metric: 1 Link connected to: a Transit Network (Link ID) Designated Router address: 192.68.130.1 (Link Data) Router Interface address: 192.68.130.
adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the keywords adv-router then the IP address of an Advertising Router to display only the LSA information about that router. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 1040 Version Description 9.8(0.
Example Item Description Network Mask Displays the network mask implemented on the area. TOS Displays the TOS options. Option 0 is the only option. Metric Displays the LSA metrics. Dell#show ip ospf 100 database summary OSPF Router with ID (1.1.1.10) (Process ID 100) Summary Network (Area 0.0.0.0) LS age: 1551 Options: (No TOS-capability, DC, E) LS type: Summary Network Link State ID: 192.68.16.0 Advertising Router: 192.168.17.
interface Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Example Item Description Transmit Delay... This line displays the interface’s settings for Transmit Delay, State, and Priority. In the State setting, BDR is Backup Designated Router. Designated Router... This line displays the ID of the Designated Router and its interface address. Backup Designated... This line displays the ID of the Backup Designated Router and its interface address. Timer intervals...
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Parameters Defaults Command Modes Command History process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
172.30.1.0 Dell# 2 13.0.0.3 Gi 1/47 1 Intra-Area show ip ospf statistics Display OSPF statistics. Syntax show ip ospf [process-id | vrf vrf-name] statistics global | [interface name {neighbor router-id}] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. The following describes the show ip ospf statistics process-id global command shown in the following example. Row Heading Description Total Displays the total number of packets the OSPF process receives/transmits.
Example Error Type Description Auth-Error Simple authentication error. MD5-Error MD5 error Cksum-Err Checksum Error Version Version mismatch AreaMismatch Area mismatch Conf-Issue The received hello packet has a different hello or dead interval than the configuration. No-Buffer Buffer allocation failure. Seq-no A sequence no errors occurred during the database exchange process. Socket Socket Read/Write operation error. Q-overflow Packets dropped due to queue overflow.
Example (Statistics) Dell(conf-if-gi-1/6)#do show ip ospf statistics Interface GigabitEthernet 1/6 Error packets (Receive statistics) Intf-Down 0 Non-Dr 0 Self-Org 0 Wrong-Len 0 Invld-Nbr 0 Nbr-State 0 Auth-Error 0 MD5-Error 0 Cksum-Err 0 Version 0 AreaMisMatch 0 Conf-Issue 0 SeqNo-Err 0 Unknown-Pkt 0 Bad-LsReq 0 RtidZero 0 Neighbor ID 4.4.4.
Example Dell#show ip ospf 10 timers rate-limit List of LSAs in rate limit Queue LSA id: 1.1.1.0 Type: 3 Adv Rtid: 3.3.3.3 Expiry time: 00:00:09.111 LSA id: 3.3.3.3 Type: 1 Adv Rtid: 3.3.3.3 Expiry time: 00:00:23.96 Dell# show ip ospf topology Display routers in directly connected areas. Syntax show ip ospf [process-id] topology Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
summary-address To advertise one external route, set the OSPF ASBR. Syntax summary-address ip-address mask [not-advertise] [tag tag-value] To disable summary address, use the no summary-address ip-address mask command. Parameters ip-address Specify the IP address in dotted decimal format of the address to summarize. mask Specify the mask in dotted decimal format of the address to summarize.
timers spf Set the time interval between when the switch receives a topology change and starts a shortest path first (SPF) calculation. S3048–ON Syntax timers spf delay holdtime To return to the default, use the no timers spf command. Parameters Defaults delay Enter a number as the delay. The range is from 0 to 4294967295. The default is 5 seconds. holdtime Enter a number as the hold time. The range is from 0 to 4294967295. The default is 10 seconds.
timers spf 2 5 Dell(conf-router_ospf-1)# Dell(conf-router_ospf-1)#end Dell# Dell# timers throttle lsa all Configure LSA transmit intervals. Syntax timers throttle lsa all {start-interval | hold-interval | max-interval} To return to the default, use the no timers throttle lsa command. Parameters Defaults start-interval Set the minimum interval between initial sending and resending the same LSA. The range is from 0 to 600,000 milliseconds. hold-interval Set the next interval to send the same LSA.
timers throttle lsa arrival Configure the LSA acceptance intervals. Syntax timers throttle lsa arrival arrival-time To return to the default, use the no timers throttle lsa command. Parameters arrival-time Set the interval between receiving the same LSA repeatedly, to allow sufficient time for the system to accept the LSA. The range is from 0 to 600,000 milliseconds. Defaults 1000 msec Command Modes ROUTER OSPF Command History This guide is platform-specific.
Parameters area area-id Area for which OSPFv3 traffic is to be authenticated. For area-id, you can enter a number. The range is from 0 to 4294967295. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295. MD5 | SHA1 Authentication type: Message Digest 5 (MD5) or Secure Hash Algorithm 1 (SHA-1). key-encryptiontype (OPTIONAL) Specifies if the key is encrypted. The values are 0 (key is not encrypted) or 7 (key is encrypted).
To remove an IPsec authentication policy from an OSPFv3 area, enter the no area area-id authentication spi number command. Related Commands ipv6 ospf authentication – configures an IPsec authentication policy on an OSPFv3 interface. show crypto ipsec policy – displays the configuration of IPsec authentication policies. area encryption Configure an IPsec encryption policy for OSPFv3 packets in an OSPFv3 area.
For MD5 authentication, the key must be 32 hex digits (non-encrypted) or 64 hex digits (encrypted). For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). null Causes an encryption policy configured for the area to not be inherited on the interface. Defaults Not configured. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific.
clear ipv6 ospf process Reset an OSPFv3 router process without removing or re-configuring the process. Syntax clear ipv6 ospf [vrf vrf-name] process Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege (Optional) Enter the keyword vrf followed by the name of the VRF to clear IPv6 routes corresponding to that VRF. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(1.0) Introduced on the Z9500. 9.2.(0.0) Introduced on the S4820T, S4810, and Z9000. The following section describes the command fields.
debug ipv6 ospf packet Display debug information and interface types on OSPF IPv6 packets. Syntax debug ipv6 ospf {packet | events} [interface] Parameters interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Lines Beginning With or Including Description Sending Ver:3 Sending OSPF3 version.. type: Displays the type of packet sent: • 1 - Hello packet • 2 - database description • 3 - link state request • 4 - link state update • 5 - link state acknowledgement • 7 - external LSA • 8 - link-state advertisement (OSPFv3) • 9 - link local LSA (OSPFv2), Intra-Area-Prefix LSA (OSPFv3) • 11 - grace LSA (OSPFv3) Length: Displays the packet length. Router ID: Displays the OSPF3 router ID.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on the E-Series.
adjacent. When graceful restart is enabled (restarting role), an OSPFv3 restarting expects its OSPFv3 neighbors to help when it restarts by not advertising the broken link. When you enable the helper-reject role on an interface with the ipv6 ospf graceful-restart helper-reject command, you reconfigure OSPFv3 graceful restart to function in a “restarting-only” role. In a “restartingonly” role, OSPFv3 does not participate in the graceful restart of a neighbor.
ipv6 ospf area Enable IPv6 OSPF on an interface. Syntax ipv6 ospf process id areaarea id To disable OSPFv6 routing for an interface, use the no ipv6 ospf process-id area area-id command. Parameters process-id Enter the process identification number. area area-id Specify the OSPF area. The range is from 0 to 65535. Defaults none Command Modes INTERFACE Command History Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.
For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1.(0.
interval milliseconds (OPTIONAL) Enter the keyword interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100. min_rx milliseconds Enter the keywords min_rx to specify the minimum rate at which the local system receives control packets from the remote system. The range is from 50 to 100. The default is 100.
Defaults Default cost based on the bandwidth. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for C-Series. 7.4.1.
Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T. Usage Information By default, the dead interval is four times longer than the default hello-interval. Related Commands ipv6 ospf hello-interval – specifies the time interval between hello packets. ipv6 ospf encryption Configure an IPsec encryption policy for OSPFv3 packets on an IPv6 interface.
key Text string used in authentication. For MD5 authentication, the key must be 32 hex digits (non-encrypted) or 64 hex digits (encrypted). For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.2 Introduced on E-Series TeraScale. 8.3.19.0 Introduced on the S4820T.
Version Description 8.3.19.0 Introduced on the S4820T. Usage Information The time interval between hello packets must be the same for routers in a network. Related Commands ipv6 ospf dead-interval – specifies the time interval between hello packets was received from a router. ipv6 ospf priority To determine the Designated Router for the OSPFv3 network, set the priority of the interface. Syntax ipv6 ospf priority number To return to the default time interval, use the no ipv6 ospf priority command.
vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(1.
passive-interface Disable (suppress) sending routing updates on an interface. Syntax passive—interface interface To enable sending routing updates on an interface, use the no passive-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
redistribute Redistribute into OSPFv3. Syntax redistribute {bgp as number}{connected | static}[metric metric-value | metric-type type-value] [route-map map-name] [tag tag-value] To disable redistribution, use the no redistribute {connected | static} command. Parameters bgp as number Enter the keyword bgp then the autonomous system number. The range is from 1 to 65535. connected Enter the keyword connected to redistribute routes from physically connected interfaces.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series.
Usage Information You can configure an arbitrary value in the IP address for each router. However, each router ID must be unique. If this command is used on an OSPFv3 process that is already active (has neighbors), all the neighbor adjacencies are brought down immediately and new sessions are initiated with the new router ID. Related Commands clear ipv6 ospf process – resets an OSPFv3 router process. show crypto ipsec policy Display the configuration of IPsec authentication and encryption policies.
Outbound ESP Auth Key : 123456789a123456789b123456789c12 Inbound ESP Cipher Key : 123456789a123456789b123456789c123456789d12345678 Outbound ESP Cipher Key : 123456789a123456789b123456789c123456789d12345678 Transform set : esp-3des esp-md5-hmac Crypto IPSec client security policy data Policy name : OSPFv3-0-501 Policy refcount : 1 Inbound ESP SPI : 501 (0x1F5) Outbound ESP SPI : 501 (0x1F5) Inbound ESP Auth Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba8ed8bb5efe91e97eb7c0 c30808825fb5 Outbound ESP A
Parameters interface interface (OPTIONAL) Displays information about the SAs used on a specified OSPFv3 interface, where interface is one of the following values: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
inbound esp sas outbound esp sas Interface: GigabitEthernet 1/2 Link Local address: fe80::201:e8ff:fe40:4d11 IPSecv6 policy name: OSPFv3-1-600 inbound ah sas outbound ah sas inbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE outbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE show crypto ipsec sa ipv6 Command Fields Field
show ipv6 ospf database Display information in the OSPFv3 database, including link-state advertisements (LSAs). Syntax show ipv6 ospf [process-number] [vrf vrf-name] database [database-summary | grace-lsa] Parameters process-number Enter the OSPF process number. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed.
LS Seq Number : 0x80000001 Checksum : 0x1DF1 Length : 36 Associated Interface : Gi 1/3 Restart Interval : 180 Restart Reason : Switch to Redundant Processor Example (databasesummary) Dell#show ipv6 ospf 3 database database-summary OSPFv3 Router with ID (1.1.1.
Parameters process-number Enter the OSPF process number. interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: Defaults none Command Modes EXEC Command History Usage Information • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Parameters process-number Enter the OSPF process number. vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display OSPF neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed.
holdtime Defaults Enter a number as the hold time. The range is from 0 to 4294967295. The default is 10 seconds. • delay = 5 seconds • holdtime = 10 seconds Command Modes ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
39 Policy-based Routing (PBR) Policy-based routing (PBR) allows you to apply routing policies to specific interfaces. To enable PBR, create a redirect list and apply it to the interface. After the redirect list is applied to the interface, all traffic passing through the interface is subject to the rules defined in the redirect list. PBR is supported by the Dell Networking Operating System (OS).
ip redirect-group Apply a redirect list (policy-based routing) on an interface. You can apply multiple redirect lists to an interface by entering this command multiple times. Syntax ip redirect-group redirect-list-name To remove a redirect list from an interface, use the no ip redirect-group name command. Parameters redirect-list-name Enter the name of a configured redirect list. Defaults none Command Modes INTERFACE (conf-if-vl-) Command History Usage Information Version Description 9.8(0.
Parameters redirect-list-name Defaults None Command Modes CONFIGURATION Command History Enter the name of a redirect list. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048–ON. 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. permit Configure a permit rule.
bit (OPTIONAL) For the TCP protocol type only, enter one or a combination of the following TCP flags: operator Defaults none Command Modes REDIRECT-LIST Command History • ack = acknowledgement • fin = finish (no more data from the user) • psh = push function • rst = reset the connection • syn = synchronize sequence number • urg = urgent field (OPTIONAL) For TCP and UDP parameters only.
| any | host ip-address} {destination mask | any | host ip-address} [operator] command. Parameters redirect Enter the keyword redirect to assign the sequence to the redirect list. ip-address Enter the IP address of the forwarding router. slot/port Enter the keyword slot / port followed by the slot/port information. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking.
Command Modes Command History REDIRECT-LIST Version Description 9.8(0.0) Introduced on the S3048-ON and S4048–ON. 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Added support for the track-id on the S4810, S4820T, S6000, and Z9000. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale.
• source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x). any Enter the keyword any to specify that all traffic is subject to the filter. host ip-address Enter the keyword host then the IP address to specify a host IP address. destination Enter the IP address of the network or host to which the packets are sent.
show cam pbr Display the PBR CAM content. Syntax show cam pbr {[interface interface] | stack—unit slot-number port-set number]} [summ Parameters interface interface Enter the keyword interface then the name of the interface. stack–unit number Enter the keyword stack-unit then the slot number. port-set number Enter the keywords port-set then the port-pipe number. summary Enter the keyword summary to view only the total number of CAM entries.
Parameters Command Modes Command History Example redirect-list-name • EXEC • EXEC Privilege Enter the name of a configured Redirect list. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048–ON. 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Dell#show ip redirect-list explicit_tunnel IP redirect-list explicit_tunnel: Defined as: seq 5 redirect tunnel 1 track 1 tcp 155.55.2.0/24 222.22.2.
40 PIM-Sparse Mode (PIM-SM) The protocol-independent multicast (PIM) commands are supported by the Dell Networking operating software on the platform. IPv4 PIM-Sparse Mode Commands The following describes the IPv4 PIM-sparse mode (PIM-SM) commands. clear ip pim rp-mapping The bootstrap router (BSR) feature uses this command to remove all or particular rendezvous point (RP) advertisement.
Usage Information This command re-applies the RP mapping logic for all the groups learnt by the node. Any stale information corresponding to the existing mapping configuration is updated. As a result, the existing BSR cache and the *,G's are deleted only if these entries are stale. clear ip pim tib Clear PIM tree information from the PIM database.
debug ip pim View IP PIM debugging messages. Syntax debug ip pim [vrf vrf-name] [bsr | events | group | packet [in | out] | register | state | timer [assert | hello | joinprune | register]] To disable PIM debugging, use the no debug ip pim [vrf vrf-name] command or use the undebug allto disable all debugging command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IP PIM debugging messages corresponding to that VRF.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. ip pim bsr-border Define the border of PIM domain by filtering inbound and outbound PIM-BSR messages per interface. Syntax ip pim bsr-border To return to the default value, use the no ip pim bsr-border command.
To return to the default value, use the no ip pim bsr-candidate [vrf vrf-name] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on a VRF. interface Enter the following keywords and slot/port or number information: • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Parameters priority-value Enter a number. Preference is given to larger/higher number. The range is from 0 to 4294967294. The default is 1. Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Removed the in and out parameters. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.
Example Dell(conf)# ip access-list standard map1 Dell(config-std-nacl)# permit 224.0.0.1/24 Dell(config-std-nacl)#exit Dell(conf)#int gig 1/1 Dell(config-if-gi-1/1)# ip pim ingress-interface-map map1 ip pim neighbor-filter To prevent a router from participating in protocol independent multicast (PIM), configure this feature. Syntax ip pim [vrf vrf-name] neighbor-filter {access-list} To remove the restriction, use the no ip pim [vrf vrf-name] neighbor-filter {accesslist} command.
ip pim query-interval Change the frequency of PIM Router-Query messages. Syntax ip pim query-interval seconds To return to the default value, use the no ip pim query-interval seconds command. Parameters seconds Enter a number as the number of seconds between router query messages. The range is from 0 to 65535. The default is 30 seconds. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information The interface must be enabled (the no shutdown command) and not have the switchport command configured. Multicast must also be enabled globally (using the ip multicast-lag-hashing command). PIM is supported on the port-channel interface. ip pim sparse-mode sg-expiry-timer Enable expiry timers globally for all sources.
ip pim ssm-range Specify the SSM group range using an access list. Syntax Parameters ip pim [vrf vrf-name] ssm-range {access_list_name} vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to specify the SSM group range for that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. access_list_name Enter the name of the access list.
When you remove the SSM ACL, PIM SSM is supported for the default SSM range only. ip pim spt-threshold To switch to the shortest path tree when the traffic reaches the specified threshold value, configure the PIM router. Syntax ip pim [vrf vrf-name] spt-threshold [infinity] To return to the default value, use the no ip pim [vrf vrf-name] spt-threshold [infinity] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on that VRF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. Dell#show ip pim bsr-router PIMv2 Bootstrap information This system is the Bootstrap Router (v2) BSR address: 7.7.7.7 (?) BSR Priority: 0, Hash mask length: 30 Next bootstrap message in 00:00:08 This system is a candidate BSR Candidate BSR address: 7.7.7.
Field Description Ver/Mode Displays the PIM version number and mode for each interface participating in PIM: • v2 = PIM version 2 • S = PIM Sparse mode Nbr Count Displays the number of PIM neighbors discovered over this interface. Query Intvl Displays the query interval for Router Query messages on that interface (configured with ip pim query-interval command). DR Prio Displays the Designated Router priority value configured on the interface (use the ip pim dr-priority command).
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. The following describes the show ip pim neighbor command shown in the following example. Field Description Neighbor address Displays the IP address of the PIM neighbor. Interface List the interface type, with either slot/port information or ID (VLAN or Port Channel), on which the PIM neighbor was found.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. Example Dell#show ip pim rp Group RP 224.2.197.115 165.87.20.4 224.2.217.146 165.87.20.
Usage Information Example (#2) Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.1 Introduced on the E-Series ExaScale. The following describes the show ip pim snooping interface commands shown in the following example. Field Description Interface Displays the VLAN interfaces with PIM-SM snooping enabled.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.1 Introduced on the E-Series ExaScale. The following describes the show ip pim snooping neighbor commands shown in the following example. Field Description Neighbor address Displays the IP address of the neighbor learned through PIM-SM snooping.
source-address Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the source address in dotted decimal format (A.B.C.D) to display TIB information PIM-SM snooping discovered for a specified multicast source. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Field Description • Example received a (*,G) Join message Dell#show ip pim snooping tib PIM Multicast Snooping Table Flags: J/P - (*,G) Join/Prune, j/p - (S,G) Join/Prune SGR-P - (S,G,R) Prune Timers: Uptime/Expires * : Inherited port (*, 225.1.2.1), uptime 00:00:01, expires 00:02:59, RP 165.87.70.1, flags: J Incoming interface: Vlan 2, RPF neighbor 0.0.0.0 Outgoing interface list: GigabitEthernet 2/11 RPF 165.87.32.
Exmaple Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. Group Address / MaskLen show ip pim summary View information about PIM-SM operation. S3048–ON Syntax show ip pim [vrf vrf-name] summary Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
1/1 (*,G) entries in PIM-TIB/MFC 1/1 (S,G) entries in PIM-TIB/MFC 0/0 (S,G,Rpt) entries in PIM-TIB/MFC 0 0 0 0 PIM nexthops RPs sources Register states Message summary: 2582/2583 Joins sent/received 5/0 Prunes sent/received 0/0 Candidate-RP advertisements sent/received 0/0 BSR messages sent/received 0/0 State-Refresh messages sent/received 0/0 MSDP updates sent/received 0/0 Null Register messages sent/received 0/0 Register-stop messages sent/received Data path event summary: 0 no-cache messages received 0
Usage Information Example Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. The following describes the show ip pim tib command shown in the following example. Field Description (S, G) Displays the entry in the multicast PIM database. uptime Displays the amount of time the entry has been in the PIM route table.
(20.10.4.9, 225.1.1.1), uptime 00:06:21, expires 00:02:06, flags: CT Incoming interface: Vlan 2007, RPF neighbor 20.30.124.4 Outgoing interface list: Vlan 2006 Forward/Sparse 00:06:21/Never (*, 225.1.1.2), uptime 00:40:15, expires 00:00:00, RP 20.40.4.4, flags: SCJ Incoming interface: Vlan 2007, RPF neighbor 20.30.124.4 Outgoing interface list: Vlan 2006 Forward/Sparse 00:06:21/Never (20.10.4.9, 225.1.1.2), uptime 00:06:21, expires 00:02:06, flags: CT Incoming interface: Vlan 2007, RPF neighbor 20.30.124.
41 Port Monitoring The port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one port to another port. Important Points to Remember • Port monitoring is supported on physical ports and logical interfaces, such as port channels and virtual local area networks (VLANs). • The monitoring (destination, “MG”) and monitored (source, “MD”) ports must be on the same switch.
Related Commands Version Description 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-7.7.1.0 Introduced on the E-Series. monitor session — enables a monitoring session. monitor multicast-queue Configure monitor QoS multicast queue ID.
monitor session Create a session for monitoring traffic with port monitoring. Syntax monitor session session-ID [type { rpm | erpm [set ip dscp dscp_value | set ip ttl ttl_value]}] [drop] To delete a session, use the no monitor session session-ID command. To delete all monitor sessions, use the no monitor session all command. Parameters session-ID Enter a session identification number. The range is from 0 to 65535.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information The monitor command is saved in the running configuration at Monitor Session mode level and can be restored after a chassis reload. Example Dell#show monitor session SessID Source Destination Dest IP DSCP TTL ------ -------------------------- --0 Gi 1/12 remote-ip 7.1.1.2 0 255 0 Po 1 remote-ip 7.1.1.2 0 255 1 Vl 11 remote-ip 3.1.1.
show config Display the current monitor session configuration. Syntax show config Defaults none Command Modes MONITOR SESSION (conf-mon-sess-session-ID) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Related Commands Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000-ON. 9.4.0.0 Added support for the RPM / ERPM. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the S4810. 8.3.11.
• For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a VLAN interface enter the keyword VLAN followed by a number from 1 to 4094. • For a port channel interface, enter the keywords port-channel then a number. range Enter the keyword range to specify the list of interfaces. any Enter the keyword any to specify all interfaces. NOTE: This option is applicable only with drop monitor session.
Example 1130 Version Description 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
42 Private VLAN (PVLAN) The private VLAN (PVLAN) feature of the Dell Networking operating software is supported on the platforms. Private VLANs extend the Dell Networking OS security suite by providing Layer 2 isolation between ports within the same private VLAN. A private VLAN partitions a traditional VLAN into subdomains identified by a primary and secondary VLAN pair. The Dell Networking OS private VLAN implementation is based on RFC 3069. For more information, refer to the following commands.
– A trunk port in a PVLAN is always tagged. – A trunk port in Tagged mode carries primary or secondary VLAN traffic. The tag on the packet helps identify the VLAN to which the packet belongs. – A trunk port can also belong to a regular VLAN (non-private VLAN). ip local-proxy-arp Enable/disable Layer 3 communication between secondary VLANs in a private VLAN.
private-vlan mode Set PVLAN mode of the selected VLAN to community, isolated, or primary. S3048 Syntax [no] private-vlan mode {community | isolated | primary} To remove the PVLAN configuration, use the no private-vlan mode {community | isolated | primary} command syntax. Parameters community Enter the keyword community to set the VLAN as a community VLAN. isolated Enter the keyword isolated to configure the VLAN as an isolated VLAN.
private-vlan mapping secondary-vlan Map secondary VLANs to the selected primary VLAN. S3048 Syntax [no] private-vlan mapping secondary-vlan vlan-list To remove specific secondary VLANs from the configuration, use the no private-vlan mapping secondary-vlan vlan-list command syntax. Parameters vlan-list Enter the list of secondary VLANs to associate with the selected primary VLAN. The list can be in comma-delimited or hyphenated-range format, following the convention for the range input.
switchport mode private-vlan Set PVLAN mode of the selected port. S3048 Syntax [no] switchport mode private-vlan {host | promiscuous | trunk} To remove PVLAN mode from the selected port, use the no switchport mode private-vlan command. Parameters host Enter the keyword host to configure the selected port or port channel as an isolated interface in a PVLAN. promiscuous Enter the keyword promiscuous to configure the selected port or port channel as an promiscuous interface.
Related Commands private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — sets the mode of the selected VLAN to primary and then associates the secondary VLANs to it.
43 Per-VLAN Spanning Tree Plus (PVST+) The Dell Networking operating software implementation of per-VLAN spanning tree plus (PVST+) is based on the IEEE 802.1w standard spanning tree protocol. Dell Networking OS supports PVST+ on the S3048 platform. NOTE: For easier command line entry, the plus (+) sign is not used at the command line. description Enter a description of the PVST+. S3048 Syntax description {description} To remove the description, use the no description {description} command.
disable Disable PVST+ globally. S3048 Syntax disable To enable PVST+, use the no disable command. Defaults Disabled. Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048–ON. 9.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 8.3.1.0 Introduced.
guard Defaults Command Modes Command History • For a Port Channel interface, enter the keyword port-channel then a number: The range is 1 to 128. • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. (OPTIONAL) Enter the keyword guard to display the type of guard enabled on a PVST interface and the current port state.
Example (Brief) Dell#show spanning-tree pvst vlan 3 brief VLAN 3 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 4096, Address 0001.e801.6aa8 Root Bridge hello time 2, max age 20, forward delay 15 Bridge ID Priority 16384, Address 0001.e805.e306 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Gi 1/0 128.130 128 20000 FWD 20000 4096 0001.e801.6aa8 128.
BPDU sent 1579, received 0 The port is in the Edge port mode Example (EDS/LBK) Dell#show spanning-tree pvst vlan 2 interface gigabitethernet 1/1 GigabitEthernet 1/1 of VLAN 2 is LBK_INC discarding Edge port:no (default) port guard :none (default) Link type: point-to-point (auto) bpdu filter:disable (default) Bpdu guard :disable (default) Bpdus sent 152, received 27562 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ----------------------------------------------------------Gi 1/1 128.
Parameters edge-port Enter the keywords edge-port to configure the interface as a PVST+ edge port. bpduguard Enter the keyword portfast to enable Portfast to move the interface into Forwarding mode immediately after the root fails. Enter the keyword bpduguard to disable the port when it receives a BPDU. shutdown-onviolation (OPTIONAL) Enter the keywords shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled.
Usage Information Version Description 8.4.2.1 Introduced the loopguard and rootguard options on the E-Series TeraScale, C-Series, and S-Series. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced the hardware shutdown-on-violation option. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional Bridge Port Data Unit (BPDU) guard. 6.2.1.1 Introduced.
Related Commands show spanning-tree pvst — views the PVST+ configuration. spanning-tree pvst err-disable Place ports in an Err-Disabled state if they receive a PVST+ BPDU when they are members an untagged VLAN. S3048 Syntax spanning-tree pvst err-disable cause invalid-pvst-bpdu Defaults Enabled; ports are placed in the Err-Disabled state if they receive a PVST+ BPDU when they are members of an untagged VLAN. Command Modes INTERFACE Command History This guide is platform-specific.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. S3048 Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
bridge-priority value Enter the keywords bridge-priority then the bridge priority value in increments of 4096. The range is from 0 to 61440. The default is 32768. Defaults 32768 Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Defaults 15 seconds Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value.
44 Quality of Service (QoS) The Dell Networking operating software commands for quality of service (QoS) include traffic conditioning and congestion control. QoS commands are not universally supported on all Dell Networking Products. platform. This chapter contains the following sections: • Global Configuration Commands • Per-Port QoS Commands • Policy-Based QoS Commands Global Configuration Commands There is only one global configuration QoS command.
Version Description 8.3.1.0 Introduced. Per-Port QoS Commands Per-port QoS (port-based QoS) allows you to define the QoS configuration on a per-physical-port basis. dot1p-priority Assign a value to the IEEE 802.1p bits on the traffic this interface receives. Syntax dot1p-priority priority-value To delete the IEEE 802.1p configuration on the interface, use the no dot1p-priority command. Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
rate police Police the incoming traffic rate on the selected interface. S3048–ON Syntax rate police [kbps] committed-rate [burst-KB] [peak [kbps] peak-rate [burstKB]] [vlan vlan-id] Parameters kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). committed-rate Enter the bandwidth in Mbps. The range is from 0 to 40000. burst-KB (OPTIONAL) Enter the burst size in KB.
rate shape Shape the traffic output on the selected interface. S3048–ON Syntax Parameters rate shape [kbps] rate [burst-KB] kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). On S-Series, make the value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). rate The range is from 10 to 40000. burst-KB (OPTIONAL) Enter the burst size in KB. The range is from 0 to 10000. The default is 50.
Parameters Defaults queue Enter a value from 0 to 7. For each dot1p Priority, the default CoS queue value is: • Dot1p Priority : 0 1 2 3 4 5 6 7 • Queue : 2 0 1 3 4 5 6 7 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Command Modes Command History dot1p Queue ID 7 3 • INTERFACE • CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. After you configure a unicast queue as strict-priority, that particular queue, on the entire chassis, is treated as a strict-priority queue. Traffic for a strict priority is scheduled before any other queues are serviced.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced on the E-Series. Usage Information The unit of bandwidth percentage is 1%. If the sum of the bandwidth percentages given to all eight classes exceeds 100%, the bandwidth percentage automatically scales down to 100%. Related Commands qos-policy-output — creates a QoS output policy. class-map Create/access a class map.
Version Description 8.2.1.0 Class-map names can be 32 characters. Layer2 available on the C-Series and SSeries. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Expanded to add support for Layer 2. Usage Information Packets arriving at the input interface are checked against the match criteria and configured using this command to determine if the packet belongs to that class.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.18.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands policy-map-input — creates an input policy map. policy-map-output — creates an output policy map. qos-policy-input — creates an input QoS-policy on the router. qos-policy-output — creates an output QoS-policy on the router. wred-profile — creates a WRED profile. match ip access-group Configure match criteria for a class map, based on the access control list (ACL). NOTE: IPv6 class-maps and IP-any class-maps do not match.
Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. For class-map match-any, a maximum of five ACL match criteria are allowed. For class-map match-all, only one ACL match criteria is allowed. Related Commands class-map — identifies the class map. match ip dscp Use a differentiated services code point (DSCP) value as a match criteria.
Up to 64 IP DSCP values can be matched in one match statement. For example, to indicate IP DCSP values 0 1 2 3 4 5 6 7, enter either the match ip dscp 0,1,2,3,4,5,6,7 or match ip dscp 0-7 command. NOTE: Only one of the IP DSCP values must be a successful match criterion, not all of the specified IP DSCP values must match. Related Commands class-map — identifies the class map. match ip precedence Use IP precedence values as a match criteria.
Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. The match ip precedence command and the match ip dscp command are mutually exclusive. Up to eight precedence values can be matched in one match statement. For example, to indicate the IP precedence values 0 1 2 3, enter either the match ip precedence 0-3 or match ip precedence 0,1,2,3 command.
match ip vrf Uses a VRF as the match criterion for an L3 class map. S3048–ON Syntax match ip vrf vrf-id To remove VRF as the match criterion, use the no match ip vrf vrf-id command. Parameters vlan vlan-id Enter the keyword vrf and then the ID of the VRF. The range is from 1 to 63. Defaults none Command Modes CONF-CLASS-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. Related Commands class-map — identifies the class map.
match mac vlan Configure a match criterion for a class map based on VLAN ID. S3048–ON Syntax match mac vlan number Parameters number Enter the VLAN ID. The range is from 1 to 4094. Defaults none Command Modes CLASS-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information If the rate shape exists in both aggregate and per-queue qos-policy, minimum of 2 take effect. Some of all Queue-rate will not exceed aggregate.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information The input policy map is used to classify incoming traffic to different flows using class-map, QoS policy, or incoming packets DSCP. This command enables Policy-Map-Input Configuration mode (conf-policy-map-in). Related Commands service-queue — assigns a class map and QoS policy to different queues. service-policy input — applies an input policy map to the selected interface.
qos-policy-input Create a QoS input policy on the router. S3048–ON Syntax qos-policy-input qos-policy-name cpu-qos | layer2 To remove an existing input QoS policy from the router, use the no qos-policy-input qos-policyname cpu-qos | layer2 command. Parameters qos-policy-name Enter the name for the policy map in character format (32 characters maximum). cpu-qos (OPTIONAL) Enter the keyword cpu-qos keyword to assign this ACL to control plane traffic only.
To remove an existing output QoS policy, use the no qos-policy-output qos-policy-name command. Parameters qos-policy-name Enter your output QoS policy name in character format (32 characters maximum). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
wred-profile name (OPTIONAL) Enter the keywords wred-profile then your WRED profile name in character format (16 character maximum). Or use one of the pre-defined WRED profile names. Pre-defined Profiles: wred_drop, wred-ge_y, wred_ge_g, wred_teng_y, wred_teng_g. multicastbandwidth percentage (OPTIONAL) Enter the keywords multicast-bandwidth then the bandwidth percentage. The range is from 0 to 100%. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
queue ingress Assign a WRED Curve to all eight ingress Multicast queues or designate the percentage for the Multicast bandwidth queue. Syntax queue ingress multicast {linecard slot number port-set number | all} [wredprofile name] To return to the default, use the no queue ingress multicast {linecard slot number port-set number | all} [wred-profile name] command. Parameters linecard number Enter the keyword linecard then the line card slot number.
rate-police Specify the policing functionality on incoming traffic. S3048–ON Syntax Parameters rate-police [kbps] committed-rate [burst-KB] [peak [kbps] peak-rate [burstKB]] kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). committed-rate Enter the bandwidth in Mbps. The range is from 0 to 40000.
rate-shape Shape traffic output as part of the designated policy. S3048–ON Syntax rate-shape [kbps] rate [burst-KB] Parameters kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). rate The range is from 10 to 40000. burst-KB (OPTIONAL) Enter the burst size in KB. The range is from 0 to 40000. The default is 100.
Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). You can identify an existing policy map or name one that does not yet exist. layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3. Defaults Layer 3 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information A single policy-map can be attached to one or more interfaces to specify the service-policy for those interfaces.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information There are eight queues per interface on the S6000 and four queues on the S-Series. This command assigns a class map or QoS policy to different queues. Related Commands class-map — identifies the class map. service-policy input — applies an input policy map to the selected interface.
show qos class-map View the current class map information. S3048–ON Syntax show qos class-map [class-name] Parameters Defaults class-name (Optional) Enter the name of a configured class map. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Usage Information trust dot1p, do1p-priority, service-class dynamic dot1; all these features work over the mapping in this command output. Related Commands service-class dot1p-mapping — Identifies the class map. show qos policy-map View the QoS policy map information.
Example (IPv4) Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Dell#show qos policy-map-input Policy-map-input PolicyMapInput Aggregate Qos-policy-name AggPolicyIn Queue# Class-map-name Qos-policy-name 0 ClassMap1 qosPolicyInput Dell# show qos policy-map-output View the output QoS policy map details.
Aggregate Qos-policy-name AggPolicyOut Queue# Qos-policy-name 0 qosPolicyOutput Dell# show qos qos-policy-input View the input QoS policy details. S3048–ON Syntax show qos qos-policy-input [qos-policy-name] Parameters Defaults qos-policy-name Enter the QoS policy name. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Command Modes Command History none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Defaults • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Dell#show qos wred-profile Wred-profile-name min-threshold wred_drop 0 wred_gig_y 467 wred_gig_g 467 wred_teng_y 467 wred_teng_g 467 max-threshold 0 4671 4671 4671 4671 max-drop-rate 100 100 50 50 25 test cam-usage Check the Input Policy Map configuration for the CAM usage.
Usage Information This feature allows you to determine if the CAM has enough space available before applying the configuration on an interface. An input policy map with both Trust and Class-map configuration, the Class-map rules are ignored and only the Trust rule is programmed in the CAM. In such an instance, the Estimated CAM output column contains the size of the CAM space required for the Trust rule and not the Class-map rule.
threshold Specify the minimum and maximum threshold values for the configured WRED profiles. S3048–ON Syntax threshold min number max number max-drop-probability To remove the threshold values, use the no threshold min number max number command. Parameters min number Enter the keyword min then the minimum threshold number for the WRED profile. The range is from 1 to 9360. max-dropprobability number Enter the keyword max-drop-probability followed by the maximum number of packets for the WRED profile.
trust Specify dynamic classification (DSCP) or dot1p to trust. S3048–ON Syntax trust {diffserv [fallback]| dot1p [fallback]} Parameters diffserv Enter the keyword diffserv to specify trust of DSCP markings. dot1p Enter the keyword dot1p to specify trust dot1p configuration. fallback Enter the keyword fallback to classify packets according to their DSCP or dot1p value as a secondary option in case no match occurs against the configured class maps.
DSCP/CP hex Range (XXX) DSCP Definition Traditional IP Precedence S6000 Internal Queue ID S-Series Internal Queue ID DSCP/CP Decimal 011XXX AF3 Flash 3 1 16–31 010XXX AF2 Immediate 2 1 16–31 001XXX AF1 Priority 1 0 0–15 000XXX BE (Best Effort) Best Effort 0 0 0–15 wred Designate the WRED profile to yellow or green traffic. S3048–ON Syntax wred {yellow | green} profile-name To remove the WRED drop precedence, use the no wred {yellow | green} [profile-name] command.
Usage Information To assign drop precedence to green or yellow traffic, use this command. If there is no honoring enabled on the input, all the traffic defaults to green drop precedence. Related Commands wred-profile — creates a WRED profile and name that profile. trust — defines the dynamic classification to trust DSCP. wred ecn To indicate network congestion, rather than dropping packets, use explicit congestion notification (ECN).
wred-profile Create a WRED profile and name the profile. S3048–ON Syntax wred-profile wred-profile-name To remove an existing WRED profile, use the no wred-profile command. Parameters wred-profile-name Enter your WRED profile name in character format (32 character maximum). Or use one of the pre-defined WRED profile names. You can configure up to 26 WRED profiles plus the five pre-defined profiles, for a total of 31 WRED profiles.
DSCP Color Map Commands The DSCP color map allows you to set the number of specific DSCP values to yellow or red. Traffic marked as yellow delivers traffic to the egress queue which will either transmit the packet if it has available bandwidth or drop the packet due to no ability to send. Traffic marked as red (high drop precedence) is dropped. dscp Sets the number of specific DSCP values for a color map profile to yellow or red.
• Each color map can only have one list of DSCP values for each color; any DSCP values previously listed for that color that are not in the new DSCP list are colored green. Example Dell(conf-dscp-color-map)# dscp yellow 9,10,11,13,15,16 Related Commands qos dscp-color-map — configures the DSCP color map qos dscp-color-policy— configures a DSCP color policy qos dscp-color-map Configure the DSCP color map.
qos dscp-color-policy Associates the DSCP color map profile with an interface so that all IP packets received on it is given a color based on that color map. Syntax dscp-color-policy color-map-profile-name To remove a color policy map profile, use the no dscp-color-policy color-map-profile-name command. Parameters color-map-profilename Enter the color map profile name. The name can have a maximum of 32 characters.
Detail Enter the detail keyword to display detailed information about a color policy on one or more interfaces. interface Enter the name of the interface that has color policy configured. Defaults None Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5.0.0 Introduced on the Z9000, S6000, S4820T, S4810, and MXL. Display all DSCP color maps.
45 Routing Information Protocol (RIP) Routing information protocol (RIP) is a distance vector routing protocol. The Dell Networking operating software supports both RIP version 1 (RIPv1) and RIP version 2 (RIPv2) on the platform. The Dell Networking OS implementation of RIP is based on IETF RFCs 2453 and RFC 1058. For more information about configuring RIP, refer to the Dell Networking OS Configuration Guide.
clear ip rip Update all the RIP routes in the Dell Networking OS routing table. S3048–ON Syntax clear ip rip Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
• For a VLAN, enter the keyword vlan then a number from 1 to 4094. database (OPTIONAL) Enter the keyword database to display messages when there is a change to the RIP database. events (OPTIONAL) Enter the keyword events to debug only RIP protocol changes. trigger (OPTIONAL) Enter the keyword trigger to debug only RIP trigger extensions. Command Modes EXEC Privilege Command History This guide is platform-specific.
Defaults Disabled. Metric: 1. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information This command ensures that route information being redistributed is converted to the same metric value.
Related Commands Version Description pre- 7.7.1.0 Introduced on the E-Series. router rip — enters ROUTER mode on the switch. distance Assign a weight (for prioritization) to all routes in the RIP routing table or to a specific route. Lower weights (“administrative distance”) are preferred. S3048–ON Syntax distance weight [ip-address mask [prefix-name]] To return to the default values, use the no distance weight [ip-address mask] command.
distribute-list in Configure a filter for incoming routing updates. S3048–ON Syntax distribute-list prefix-list-name in [interface] To delete the filter, use the no distribute-list prefix-list-name in command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
distribute-list out Configure a filter for outgoing routing updates. S3048–ON Syntax distribute-list prefix-list-name out [interface | bgp | connected | isis | ospf | static] To delete the filter, use the no distribute-list prefix-list-name out command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number.
Related Commands Version Description pre- 6.2.1.1 Introduced on the E-Series. ip prefix-list — enters PREFIX-LIST mode and configures a prefix list. ip poison-reverse Set the prefix of the RIP routing updates to the RIP infinity value. S3048–ON Syntax ip poison-reverse To disable poison reverse, use the no ip poison-reverse command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific.
To return to the default, use the no ip rip receive version command. Parameters 1 (OPTIONAL) Enter the number 1 for RIP version 1. 2 (OPTIONAL) Enter the number 2 for RIP version 2. Defaults RIPv1 and RIPv2 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
2 (OPTIONAL) Enter the number 2 for RIP version 2. Defaults RIPv1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. ip poison-reverse — sets the prefix for RIP routing updates.
Usage Information Version Description pre- 6.2.1.1 Introduced on the E-Series. RIP supports a maximum of 16 ECMP paths. neighbor Define a neighbor router with which to exchange RIP information. S3048–ON Syntax neighbor ip-address To delete a neighbor setting, use the no neighbor ip-address command. Parameters ip-address Enter the IP address, in dotted decimal format, of a router with which to exchange information. Defaults Not configured.
network Enable RIP for a specified network. To enable RIP on all networks connected to the switch, use this command. S3048–ON Syntax network ip-address To disable RIP for a network, use the no network ip-address command. Parameters ip-address Specify an IP network address in dotted decimal format. You cannot specify a subnet. Defaults No RIP network is configured. Command Modes ROUTER RIP Command History This guide is platform-specific.
To delete an offset list, use the no offset-list prefix-list-name {in | out} offset [interface] command. Parameters prefix-list-name Enter the name of an established Prefix list to determine which incoming routes are modified. offset Enter a number from zero (0) to 16 to be applied to the incoming route metric matching the access list specified. If you set an offset value to zero (0), no action is taken.
output-delay Set the interpacket delay of successive packets to the same neighbor. S3048–ON Syntax output-delay delay To return to the switch software defaults for interpacket delay, use the no output-delay command. Parameters delay Specify a number of milliseconds as the delay interval. The range is from 8 to 50. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific.
• For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a VLAN, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters connected Enter the keyword connected to specify that information from active routes on interfaces is redistributed. static Enter the keyword static to specify that information from static routes is redistributed. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
level-1-2 (OPTIONAL) Enter the keywords level-1-2 to redistribute both IS-IS Level-1 and Level-2 routes. level-2 (OPTIONAL) Enter the keywords level-2 to redistribute only IS-IS Level-2 routes. metric metric-value (OPTIONAL) Enter the keyword metric then a number as the metric value. The range is from 0 to 16. route-map mapname (OPTIONAL) Enter the keywords route-map then the name of a configured route map. Defaults Not configured.
route-map mapname (OPTIONAL) Enter the keywords route-map then the name of a configured route map. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable RIP, assign a network address using the network command. Example Dell(conf)#router rip Dell(conf-router_rip)# Related Commands network — enables RIP. exit — returns to CONFIGURATION mode.
router rip network 172.31.0.0 passive-interface GigabitEthernet 1/1 Dell(conf-router_rip)# show ip rip database Display the routes that RIP learns. If the switch learned no RIP routes, no output is generated. S3048–ON Syntax show ip rip database [ip-address mask] Parameters ip-address (OPTIONAL) Specify an IP address in dotted decimal format to view RIP information on that network only. If you enter an IP address, also enter a mask for that IP address.
Example Field Description 209.9.16.0/24... Lists the routes and the sources advertising those routes. Dell#show ip rip database Total number of routes in RIP database: 1624 204.250.54.0/24 [50/1] via 192.14.1.3, 00:00:12, GigabitEthernet 1/15 204.250.54.0/24 auto-summary 203.250.49.0/24 [50/1] via 192.13.1.3, 00:00:12, GigabitEthernet 1/14 203.250.49.0/24 auto-summary 210.250.40.0/24 [50/2] via 1.1.18.2, 00:00:14, Vlan 18 [50/2] via 1.1.130.2, 00:00:12, Port-channel 30 210.250.40.0/24 auto-summary 207.
Example Version Description 7.6.1.0 Introduced on the E-Series. show running-config rip ! router rip distribute-list Test1 in distribute-list Test21 out network 10.0.0.0 passive-interface GigabitEthernet 2/1 neighbor 20.20.20.20 redistribute ospf 999 version 2 timers basic Manipulate the RIP timers for routing updates, invalid, holddown times, and flush time. S3048–ON Syntax timers basic update invalid holddown flush To return to the default settings, use the no timers basic command.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series.
Related Commands Version Description 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. ip rip receive version — sets the RIP version the interface receives. ip rip send version — sets the RIP version the interface sends.
46 Remote Monitoring (RMON) The Dell Networking operating software remote monitoring (RMON) is implemented on the S3048–ON platform. Dell Networking OS RMON is based on IEEE standards, providing both 32-bit and 64-bit monitoring and long-term statistics collection.
interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rmon collection history Enable the RMON MIB history group of statistics collection on an interface. S3048–ON Syntax rmon collection history {controlEntry integer} [owner name] [buckets number] [interval seconds] To remove a specified RMON history group of statistics collection, use the no rmon collection history {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value.
rmon collection statistics Enable RMON MIB statistics collection on an interface. S3048–ON Syntax rmon collection statistics {controlEntry integer} [owner name] To remove RMON MIB statistics collection on an interface, use the no rmon collection statistics {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value. Then enter an integer value from 1 to 65535 that identifies the RMON Statistic Table.
Parameters number Assign an event number in integer format. The range is from 1 to 65535. You must ensure that the value you enter is unique in the RMON event table. log (OPTIONAL) Enter the keyword log to generate an RMON event log. This option sets the eventType to either log or log-and-snmptrap in the RMON event table. The default is None. trap community (OPTIONAL) Enter the keyword trap followed by the SNMP community string to generate SNMP traps for an RMON event entry.
Parameters number Enter the alarm integer number from 1 to 65535. The value must be unique in the RMON alarm table. variable The MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object type must be a 64-bit integer. interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables.
show rmon Display the RMON running status including the memory usage. S3048–ON Syntax show rmon Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000-ON.
brief (OPTIONAL) Enter the keyword brief to display the RMON alarm table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
19 20 21 22 Dell# 1.3.6.1.2.1.1.3 1.3.6.1.2.1.1.3 1.3.6.1.2.1.1.3 1.3.6.1.2.1.1.3 show rmon events Display the contents of the RMON event table. S3048–ON Syntax Parameters show rmon events [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON event table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific.
RMON event entry 112 description: event type: LOG. event community: event last time sent: none event owner: event status: OK RMON event entry 113 description: event type: SNMP TRAP. event community: private event last time sent: none event owner: event status: OK RMON event entry 114 description: event type: LOG and SNMP TRAP.
brief (OPTIONAL) Enter the keyword brief to display the RMON High-Capacity alarm table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.
show rmon history Display the contents of the RMON Ethernet history table. S3048–ON Syntax show rmon history [index] [brief] Parameters index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet history table in an easy-to-read format Defaults none Command Modes EXEC Command History This guide is platform-specific.
9004 134791198 GigabitEthernet 3/1 Dell# show rmon log Display the contents of the RMON log table. S3048–ON Syntax Parameters show rmon log [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easyto-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific.
4 Dell# 4 show rmon statistics Display the contents of RMON Ethernet statistics table. S3048–ON Syntax show rmon statistics [index] [brief] Parameters index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet statistics table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific.
65-127 bytes packets: 0 128-255 bytes packets: 0 256-511 bytes packets: 0 512-1023 bytes packets: 0 1024-1518 bytes packets: 0 owner: 1 status: OK HC packets received overflow: 0 HC packets received: 0 HC bytes received overflow: 0 HC bytes received: 0 HC 64bytes packets overflow: 0 HC 64bytes packets: 0 HC 65-127 bytes packets overflow: 0 HC 65-127 bytes packets: 0 HC 128-255 bytes packets overflow: 0 HC 128-255 bytes packets: 0 HC 256-511 bytes packets overflow: 0 HC 256-511 bytes pac
47 Rapid Spanning Tree Protocol (RSTP) The Dell Networking operating software implementation of rapid spanning tree protocol (RSTP) is based on the IEEE 802.1w standard spanning-tree protocol. The RSTP algorithm configures connectivity throughout a bridged local area network (LAN) that is comprised of LANs interconnected by bridges. Dell Networking OS supports RSTP. bridge-priority Set the bridge priority for RSTP.
debug spanning-tree rstp Enable debugging of RSTP and view information on the protocol. Syntax debug spanning-tree rstp [all | bpdu interface {in | out} | events] To disable debugging, use the no debug spanning-tree rstp command. Parameters all (OPTIONAL) Enter the keyword all to debug all spanning tree operations. bpdu interface {in | out} (OPTIONAL) Enter the keyword bpdu to debug the bridge protocol data units.
Example Dell#debug spanning-tree rstp bpdu gigabitethernet 2/1 ? in Receive (in) out Transmit (out) description Enter a description of the rapid spanning tree. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the rapid spanning tree (80 characters maximum). Defaults none Command Modes SPANNING TREE (The prompt is “config-rstp”.) Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. hello-time — changes the time interval between BPDUs. max-age — changes the wait time before RSTP refreshes the protocol configuration information. hello-time Set the time interval between the generation of the RSTP bridge protocol data units (BPDUs).
Usage Information The hello time is encoded in BPDUs in increments of 1/256ths of a second. The standard minimum hello time in seconds is 1 second, which is encoded as 256. Millisecond hello times are encoded using values less than 256; the millisecond hello time equals (x/1000)*256. When you configure millisecond hellos, the default hello interval of 2 seconds is still used for edge ports; the millisecond hello interval is not used.
protocol spanning-tree rstp To configure RSTP, enter RSTP mode. Syntax protocol spanning-tree rstp To exit RSTP mode, use the exit command. Defaults Not configured Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Usage Information Example (Brief) Version Description 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Expanded to display the port error disable state (EDS) caused by loopback BPDU inconsistency. 6.2.1.1 Introduced on the E-Series. The following describes the show spanning-tree rstp guard command shown in the following example. Field Description Interface Name RSTP interface. Instance RSTP instance.
Root Identifier has priority 32768, Address 0001.e801.6aa8 Root Bridge hello time 2, max age 20, forward delay 15, max hops 0 Bridge Identifier has priority 32768, Address 0001.e801.6aa8 Configured hello time 2, max age 20, forward delay 15, max hops 0 We are the root Current root has priority 32768, Address 0001.e801.
shutdown-onviolation (OPTIONAL) Enter the keywords shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. priority priority Enter keyword priority then a value in increments of 16 as the priority. The range is from 0 to 240. The default is 128. loopguard Enter the keyword loopguard to enable loop guard on an RSTP port or portchannel interface. rootguard Enter the keyword rootguard to enable root guard on an RSTP port or portchannel interface.
Enabling Portfast BPDU guard and loop guard at the same time on a port results in a port that remains in a Blocking state and prevents traffic from flowing through it. For example, when Portfast BPDU guard and loop guard are both configured: Example • If a BPDU is received from a remote device, BPDU guard places the port in an Err-Disabled Blocking state and no traffic is forwarded on the port.
during topology changes. However, if a standards-based flush mechanism is needed, you can turn on this knob command to enable flushing MAC addresses after receiving every topology change notification.
48 Software-Defined Networking (SDN) Dell Networking operating software supports Software-Defined Networking (SDN). For more information, refer to the SDN Deployment Guide.
49 Security The commands in this chapter are available on Dell Networking OS. This chapter contains various types of security commands offered in the Dell Networking operating software. The commands are listed in the following sections: • AAA Accounting Commands • Authorization and Privilege Commands • Authentication and Password Commands • RADIUS Commands • TACACS+ Commands • Port Authentication (802.
commands {level | role role-name Enter the keyword command then a privilege level for accounting of commands executed at that privilege level or enter the keyword role then the role name for accounting of commands executed by a user with that user role. name | default Enter one of the following: • For name, enter a user-defined name of a list of accounting methods. • For default, the default accounting methods used.
Example Dell(conf)# aaa accounting exec default start-stop tacacs+ Dell(conf)# aaa accounting command 15 default start-stop tacacs+ Dell(conf)# aaa accounting command role secaadmin default start-stop tacacs + Related Commands enable password — changes the password for the enable command. login authentication — enables AAA login authentication on the terminal lines. password — creates a password. tacacs-server host — specifies a TACACS+ server host.
Related Commands Version Description 6.3.1.0 Introduced on the E-Series. aaa accounting — enables AAA Accounting and creates a record for monitoring the accounting function. aaa accounting suppress Prevent the generation of accounting records of users with the user name value of NULL. Syntax aaa accounting suppress null-username To permit accounting records to users with user name value of NULL, use the no aaa accounting suppress null-username command.
Parameters group-name Enter the name of the RADIUS server group. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series. Usage Information This command steps through all active sessions and then displays the accounting records for the active account functions.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, MXL 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
aaa authorization exec Set parameters that restrict (or permit) a user’s access to EXEC-level commands. Syntax aaa authorization exec {name | default} {local || tacacs+ || ifauthenticated || none} To disable authorization checking for EXEC level commands, use the no aaa authorization exec command. Parameters name Define a name for the list of authorization methods. default Define the default list of authorization methods. local Use the authorization parameters on the system to perform authorization.
level level • exec for EXEC mode • interface for INTERFACE modes • line for LINE mode • route-map for ROUTE-MAP mode • router for ROUTER OSPF, ROUTER RIP, ROUTER ISIS and ROUTER BGP modes Enter the keyword level then a number for the access level. The range is from 0 to 15. Level 1 is EXEC mode and Level 15 allows access to all CLI modes and commands. reset Enter the keyword reset to return the security level to the default setting.
Level 1 is EXEC mode and Level 15 allows access to all CLI modes. Defaults level = 15 Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
Usage Information Version Description 9.6(0.0) Introduced on the S4810, S4820T, S5000, S6000, Z9000, Z9500, MXL By default, the service password-encryption command stores encrypted passwords. For greater security, you can also use the service obscure-passwords command to prevent a user from reading the passwords and keys, including RADIUS, TACACS+ keys, router authentication strings, VRRP authentication by obscuring this information.
... method2 • none: no authentication. • radius: use the RADIUS servers configured with the radius-server host command. • tacacs+: use the TACACS+ server(s) configured with the tacacs-server host command. (OPTIONAL) In the event of a “no response” from the first method, Dell Networking OS applies the next configured method. Defaults Use the enable password. Command Modes CONFIGURATION Command History This guide is platform-specific.
aaa authentication login Configure AAA Authentication method lists for user access to EXEC mode (Enable log-in). Syntax aaa authentication login {method-list-name | default} method [... method4] To return to the default setting, use the no aaa authentication login {method-list-name | default} command. Parameters method-list-name Enter a text string (up to 16 characters long) as the name of a user-configured method list that can be applied to different lines.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. By default, the locally configured username password is used. If you configure aaa authentication login default, Dell Networking OS uses the methods this command defines for login instead. Methods configured with the aaa authentication login command are evaluated in the order they are configured.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. line — applies an authentication method list to the designated terminal lines.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.6.0.0 Revised introductory and usage guidelines description. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
lockout-period minutes (OPTIONAL) Enter the keyword lockout-period then the number of minutes. The range is from 1 to 1440 minutes. The default is 0 minutes and the lockoutperiod is not enabled. This parameter enhances the security of the switch by locking out sessions on the Telnet or SSH sessions for which there has been a consecutive failed login attempts. The console is not locked out.
service password-encryption Encrypt all passwords configured in Dell Networking OS. Syntax service password-encryption To store new passwords as clear text, use the no service password-encryption command. Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show user command shown in the following example. Field Description (untitled) Indicates with an asterisk (*) which terminal line you are using.
• AUX: the range is from 1 to 300 seconds, the default is 0 seconds (no timeout). Defaults See the defaults settings shown in Parameters. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.
• 0 directs the system to store the password as clear text. It is the default encryption type when using the password option. • 7 to indicate that a password encrypted using a DES hashing algorithm follows. This encryption type is available with the password option only. • 5 to indicate that a password encrypted using an MD5 hashing algorithm follows. This encryption type is available with the secret option only, and is the default encryption type for this option.
RADIUS Commands The following RADIUS commands are supported by Dell Networking OS. debug radius View RADIUS transactions to assist with troubleshooting. Syntax debug radius To disable debugging of RADIUS, use the no debug radius command. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. radius-server group Creates or deletes a group of radius servers. Syntax Parameters radius-server group group-name group-name Enter the group name that denotes the group of RADIUS servers. Defaults Not configured.
radius-server host Configure a RADIUS server host. Syntax radius-server host {hostname | ipv4-address | ipv6-address} [auth-port port-number] [retransmit retries] [timeout seconds] [key [encryption-type] key] Parameters hostname Enter the name of the RADIUS server host. ipv4-address | ipv6address Enter the IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) of the RADIUS server host. auth-port portnumber (OPTIONAL) Enter the keywords auth-port then a number as the port number.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. To configure any number of RADIUS server hosts for each server host that is configured, use this command.
Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a RADIUS server group with that VRF. interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
radius-server key Configure a key for all RADIUS communications between the switch and the RADIUS host server. Syntax radius-server key [encryption-type] key To delete a password, use the no radius-server key command. Parameters encryption-type key (OPTIONAL) Enter either zero (0) or 7 as the encryption type for the key entered. The options are: • 0 is the default and means the key is not encrypted and stored as clear text. • 7 means that the key is encrypted and hidden.
radius-server retransmit Configure the number of times the switch attempts to connect with the configured RADIUS host server before declaring the RADIUS host server unreachable. Syntax radius-server retransmit retries To configure zero retransmit attempts, use the no radius-server retransmit command. To return to the default setting, use the radius-server retransmit 3 command. Parameters retries Enter a number of attempts that FTOS tries to locate a RADIUS server. The range is from zero (0) to 100.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information If the TACACS group is not configured for Authentication, Authorization, and Accounting, then globally configured TACACS servers are used for the purposes. When the TACACS group is removed, the AAA configuration is also removed. Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server host 1.1.1.1 key secret Dell(conf-tacacs-group)#tacacs-server host 2.2.2.
ip tacacs source-interface Specify an interface’s IP address as the source IP address for TACACS+ connections. Syntax ip tacacs source-interface interface To delete a source interface, use the no ip tacacs source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
Parameters group-name Enter the name of the TACACS server group. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.
key key (OPTIONAL) Enter the keyword key then a string up to 42 characters long as the authentication key. This authentication key must match the key specified in the tacacs-server key for the TACACS+ daemon. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands aaa authentication login — specifies the login authentication method. tacacs-server key — configures a TACACS+ key for the TACACS server. tacacs-server key Configure a key for communication between a TACACS+ server and a client. Syntax tacacs-server key [encryption-type] key To delete a key, use the no tacacs-server key key command. Parameters encryption-type key (OPTIONAL) Enter either zero (0) or 7 as the encryption type for the key entered.
To delete the association between a TACACS server group and a VRF and source interface, use the no tacacs-server vrf vrf-name [source-interface interface] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a TACACS server group with that VRF. interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information.
Port Authentication (802.1X) Commands An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only Extensible Authentication Protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. Dell Networking OS supports RADIUS and Active Directory environments using 802.1X Port Authentication.
Related Commands Version Description 7.4.1.0 Introduced on the E-Series. dot1x authentication (Interface) — enables dot1x on an interface. dot1x authentication (Interface) Enable dot1x on an interface; dot1x must be enabled both globally and at the interface level. Syntax dot1x authentication To disable dot1x on an interface, use the no dot1x authentication command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.6.1.
Version Description 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured.
dot1x reauthentication — enables periodic re-authentication. show dot1x interface — displays the 802.1X information on an interface. dot1x mac-auth-bypass Enable MAC authentication bypass. If 802.1X times out because the host did not respond to the Identity Request frame, Dell Networking OS attempts to authenticate the host based on its MAC address. Syntax [no] dot1x mac-auth-bypass Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x port-control Enable port control on an interface.
dot1x quiet-period Set the number of seconds that the authenticator remains quiet after a failed authentication with a client. Syntax dot1x quiet-period seconds To disable quiet time, use the no dot1x quiet-time command. Parameters seconds Enter the number of seconds. The range is from 1 to 65535. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces.
To return to the default, use the no dot1x server-timeout command. Parameters seconds Enter a time-out value in seconds. The range is from 1 to 300, where 300 is implementation dependant. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x tx-period Configure the intervals at which EAPOL PDUs are transmitted by the Authenticator PAE. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted.
Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. none Command Modes Command History • EXEC • EXEC privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
802.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Added support for FIPS mode on the S4810. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The host keys are required for key-exchange by the SSH server.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, MXL debug ip ssh Enables collecting SSH debug information. Syntax debug ip ssh {client | server} To disable debugging, use the no debug ip ssh {client | server} command. Parameters client Enter the keyword client to enable collecting debug information on the client.
Parameters directory Enter a directory name. Defaults The internal flash (flash:) is the default directory. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. This command specifies the maximum number of attempts to authenticate a user on an SSH connection with the remote host for password authentication. SSH disconnects when the number of password failures exceeds authentication-retries.
Parameters enable Enter the keyword enable to enable hostbased-authentication for SSHv2 server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. With password authentication enabled, you can authenticate using the local, RADIUS, or TACACS+ password fallback order as configured. ip ssh pub-key-file Specify the file used for host-based authentication. Syntax ip ssh pub-key-file {WORD} Parameters WORD Enter the file name for the host-based authentication.
Example Dell#conf Dell(conf)# ip ssh pub-key-file flash://knownhosts Dell(conf)# Related Commands show ip ssh client-pub-keys — displays the client-public keys used for the host-based authentication. ip ssh rekey Configures the time rekey-interval or volume rekey-limit threshold at which to re-generate the SSH key during an SSH session. Syntax ip ssh rekey [time rekey-interval] [volume rekey-limit] To reset to the default, use no ip ssh rekey [time rekey-interval] [volume rekeylimit] command.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Enabling RSA authentication allows the user to log in without being prompted for a password.
mac hmacalgorithm • aes256-cbc • aes128-ctr • aes192-ctr • aes256-ctr Enter the keyword mac then a space-delimited list of hash message authentication code (HMAC) algorithms supported by the SSH server for keying hashing for the message authentication. The following HMAC algorithms are available: • hmac-sha1 • hmac-sha1-96 • hmac-sha2-256 • hmac-sha2-256-96 When FIPS is enabled, the default HMAC algorithm is hmac-sha1-96.
NOTE: If you enable FIPS mode, you can only select version 2. Defaults • Default listening port is 22. • Default cipher list is 3des-cbc,aes128-cbc,aes192-cbc,aes256-cbc,aes128-ctr,aes192-ctr,aes256-ctr. • When FIPS is enabled, the default is hmac-sha1-96. • When FIPS is not enabled, the default is hmac-md5,hmac-md5-96,hmac-sha1,hmac-sha1-96,hmacsha2-256,hmac-sha2-256-96. • When FIPS is enabled, the default is diffie-hellman-group14-sha1.
ip ssh server vrf Configure an SSH server on either a specific VRF or a management VRF. Syntax NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative. ip ssh server vrf {management | vrf-name} To disable the SSH server configuration, use the no ip ssh server vrf {management | vrfname} command.
To delete a source interface, use the no ip ssh source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4(0.0) Introduced on the S-Series and Z9000.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command is useful if the remote SSH client implements Strict Host Key Checking.
Example Dell#show ip ssh SSH server : enabled. SSH server version : v1 and v2. SSH server vrf : default. SSH server ciphers : 3des-cbc,aes128-cbc,aes192-cbc,aes256cbc,aes128-ctr,aes192-ctr,aes256-ctr. SSH server macs : hmac-md5,hmac-md5-96,hmac-sha1,hmacsha1-96,hmac-sha2-256,hmac-sha2-256-96. SSH server kex algorithms : diffie-hellman-group-exchange-sha1,diffiehellman-group1-sha1,diffie-hellman-group14-sha1. Password Authentication : enabled. Hostbased Authentication : disabled.
+QJkqtyiwDPmH4njyDMYDCXY85vc55ibWsN9qalagklnh2cj2q4nYj5x8+8OOhYeFPaHiygd8U/ FXict61jWs84Co1UTsAgRzDJ9aUSS75TVac= root@dt-maa-linux-1.force10networks.c om 2200:2200:2200:2200:2200::2202 ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAu5NoTbmnLxBknaeXZmUJMupNwNUoGlo1/ yLPI5eehQTyaldRPHtGyPlcmMbCH +QJkqtyiwDPmH4njyDMYDCXY85vc55ibWsN9qalagklnh2cj2q4nYj5x8+8OOhYeFPaHiygd8U/ FXict61jWs84Co1UTsAgRzDJ9aUSS75TVac= root@dt-maa-li nux-1.force10networks.com 10.16.151.
Dell# Related Commands ip ssh rsa-authentication (Config) — configures the RSA authorized keys. ssh Open an SSH connection specifying the hostname, username, encryption cipher, HMAC algorithm, port number, and version of the SSH client. Syntax NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative.
-p port-number (OPTIONAL) Enter the keyword -p then the port number. The range is from 1 to 65535. The default is 22. -v {1 | 2} (OPTIONAL) Enter the keyword -v then the SSH version 1 or 2. The default is the version from the protocol negotiation. Defaults As shown in the Parameters section. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
clear ip dhcp snooping Clear the DHCP binding table. Syntax clear ip dhcp snooping binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
ip dhcp snooping Enable DHCP Snooping globally. Syntax [no] ip dhcp snooping Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
• Defaults For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. slot/port Enter the slot and port number of the interface. lease time Enter the keyword lease then the amount of time the IP address is leased. The range is from 1 to 4294967295. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.5(0.0) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping database renew Renew the binding table. Syntax ip dhcp snooping database renew Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp source-address-validation Enable IP source guard. Syntax [no] ip dhcp source-address-validation Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. When enabled, the system begins creating entries in the binding table for the specified VLANs.
Role-Based Access Control Commands With Role-Based Access Control (RBAC), access and authorization is controlled based on a user’s role. Users are granted permissions based on their user roles, not on their individual user ID. User roles are created for job functions and through those roles they acquire the permissions to perform their associated job function. This section describes the syntax and usage of RBAC-specific commands.
5. Related Commands Verify the configuration has been applied to the console or VTY line. login authentication, password, radius-server host, tacacs-server host enable Enter EXEC Privilege mode or any other privilege level configured. After entering this command, you may need to enter a password. Syntax Parameters enable [level] level (OPTIONAL) Enter a number for a privilege level of Dell Networking OS. The range is from 0 to 15.
role Changes command permissions for roles. Syntax role mode { { { addrole | deleterole } role-name } | reset } command To delete access to a command, use the no role mode role-name Parameters mode Enter one of the following keywords as the mode for which you are controlling access: configure for CONFIGURATION mode exec for EXEC mode interface for INTERFACE modes line for LINE mode route-map for Route-map mode router for Router mode addrole Enter the keyword addrole to add permission to the command.
Parameters command Enter the command’s keywords to assign the command to a certain access level. You can enter one or all of the keywords. mode mode Enter keyword then one of the following modes. Defaults none Command Modes EXEC Privilege Command History Examples • configure • exec • interface • line • route-map • router Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, MXL. userrole, username userrole Create user roles for the role-based security model. Syntax userrole name inherit existing-role-name To delete a role name, use the no userrole name command. Note that the reserved role names may not be deleted. Parameters name Enter a text string for the name of the user up to 63 characters.
Related Commands role mode { { { addrole | deleterole } role-name } | reset } command – Modifies (adds or deletes) command permissions for newly created user roles and system defined roles.
50 Service Provider Bridging Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider Backbone Bridging as described in the Dell Networking OS Configuration Guide Service Provider Bridging chapter. This chapter includes command line information (CLI) for the Dell Networking operating software Layer 2 Protocol Tunneling (L2PT). L2PT enables protocols to tunnel through an 802.1q tunnel. Dell Networking OS supports L2PT on Dell Networking OS.
• For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. in | out | both Enter the keyword in, out, or both to debug incoming interfaces, outgoing interfaces, or both incoming and outgoing interfaces. vlan vlan-id Enter the keyword vlan then the VLAN ID. The range is from 1 to 4094. count value Enter the keyword count then the number of debug outputs. The range is from 1 to 100. Defaults Debug disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guid. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.1 Added support for 802.
Version Description 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, and S-Series. 7.4.1.0 Introduced Usage Information When you enable VLAN-Stacking, no protocol packets are tunneled. Related Command show protocol-tunnel — displays tunneling information for all VLANs. protocol-tunnel enable Enable protocol tunneling globally on the system. Syntax protocol-tunnel enable To disable protocol tunneling, use the no protocol-tunnel enable command. Defaults Disabled.
Parameters rate Enter the rate in frames per second. The range is from 75 to 3000. The default is 75. Defaults 75 frames per second. Command Modes CONF-IF-VLAN-STACK Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
51 sFlow The Dell Networking operating software (OS) supports sFlow commands on Dell Networking OS. Dell Networking operating software sFlow monitoring system includes an sFlow Agent and an sFlow Collector. • The sFlow Agent combines the flow samples and interface counters into sFlow datagrams and forwards them to the sFlow Collector. • The sFlow Collector analyses the sFlow Datagrams received from the different devices and produces a network-wide view of traffic flows.
To delete a configured collector, use the no sflow collector {ip-address | ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] command. Parameters sflow collector ipaddress | ipv6address Enter the IP address of the collector in dotted decimal format for IPv4 or x:x:x:x::x format for IPv6.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. You can configure up to two sFlow collectors (IPv4 or IPv6). If two collectors are configured, traffic samples are sent to both. The sFlow agent address is carried in a field in SFlow packets and is used by the collector to identify the sFlow agent. In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the collector.
Version Description 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information sFlow is disabled by default. In addition to this command, sFlow needs to be enable on individual interfaces where sFlow sampling is desired. Related Commands sflow enable (Interface) — enables sFlow on interfaces. sflow ingress-enable Enable sFlow ingress on interfaces.
Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S Series and Z Series switches.
Usage Information The polling interval for an interface is the maximum number of seconds between successive samples of counters sent to the collector. This command changes the global default counter polling (20 seconds) interval. You can configure an interface to use a different polling interval. Related Commands sflow polling-interval (Interface) — sets the polling interval for an interface.
sflow sample-rate (Global) Change the global default sampling rate. Syntax sflow sample-rate value To return to the default sampling rate, use the no sflow sample-rate command. Parameters value Enter the sampling rate value. For the C-Series and S-Series, the range is from 256 to 8388608 packets Enter values in powers of 2 only; for example, 4096, 8192, 16384, and so on. The default is 32768 packets.
To return to the default sampling rate, use the no sflow sample-rate command. Parameters value Enter the sampling rate value. For the C-Series and S-Series, the range is from 256 to 8388608 packets. Enter values in powers of 2 only; for example, 4096, 8192, 16384, etc. The default is 32768 packets. Defaults The Global default sampling. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command Modes Command History • EXEC • EXEC Privilege • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 1 to 11. The port range is 1. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
based on line speed if global sampling rate is default Dell# 1356 sFlow
52 Simple Network Management Protocol (SNMP) and Syslog This chapter contains commands to configure and monitor the simple network management protocol (SNMP) v1/v2/v3 and Syslog. Both features are supported on Dell Networking OS. The chapter contains the following sections: • SNMP Commands • Syslog Commands SNMP Commands The following SNMP commands are available in the Dell Networking OS.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. Example Dell#show snmp engineID Local SNMP engineID: 0000178B02000001E80214A8 Remote Engine ID IP-addr Port 80001F88043132333435 172.31.1.3 5009 80001F88043938373635 172.31.1.
Usage Information The following Example displays a group named ngroup. The ngroup has a security model of version 3 (v3) with authentication (auth), the read and notify name is nview with no write view name specified, and finally the row status is active.
snmp ifmib ifalias long Display the entire description string through the Interface MIB, which would be truncated otherwise to 63 characters. Syntax snmp ifmib ifalias long Defaults Interface description truncated beyond 63 characters. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
security-name name] | access-list-name [ipv6 ipv6-access-list-name | access-list-name | security-name name]]] To remove access to a community, use the no snmp-server community community-string {ro | rw} [security-name name [access-list-name | ipv6 access-list-name | access-list-name ipv6 access-list-name]] command. Parameters community-name Enter a text string (up to 20 characters long) to act as a password for SNMP. ro Enter the keyword ro to specify read-only permission.
• v1v2cwriteu/ v1v2cwriteg — maps to a community with rw (read-write) permissions. The community-name parameter indexes this command. If you do not configure the snmp-server community command, you cannot query SNMP data. Only Standard IPv4 ACL and IPv6 ACL is supported in the optional access-list-name. The command options ipv6, security-name, and access-list-name are recursive.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command snmp-server enable traps Enable SNMP traps. Syntax snmp-server enable traps [notification-type] [notification-option] To disable traps, use the no snmp-server enable traps [notification-type] [notification-option] command.
• linkdown • linkup • syslog-reachable • syslog-unreachable Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the following two SNMP notification options: syslog-reachable and syslog-unreachable.
Parameters local engineID Enter the keyword local followed by the engine ID number that identifies the copy of the SNMP on the local device. Format (as specified in RFC 3411): 12 octets. • The first four octets are set to the private enterprise number. • The remaining eight octets are the MAC address of the chassis. remote ip-address Enter the keyword remote followed by the IP address that identifies the copy of the SNMP on the remote device.
show running-config snmp — displays the SNMP running configuration. snmp-server group Configure a new SNMP group or a table that maps SNMP users to SNMP views.
access-list-name ipv6 access-listname (Optional) Enter both an IPv4 and IPv6 access list name. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON.
Parameters ip-address Enter the keyword host then the IP address of the host (configurable hosts is limited to 16). ipv6-address Enter the keyword host then the IPv6 address of the host in the x:x:x:x::x format. NOTE: The :: notation specifies successive hexadecimal fields of zero. traps (OPTIONAL) Enter the keyword traps to send trap notifications to the specified host. The default is traps. informs (OPTIONAL) Enter the keyword informs to send inform notifications to the specified host.
• pfc — Enable pfc traps • snmp — Enable SNMP trap • stp — Enable 802.1d state change traps • vlt — Enable VLT traps • vrrp — Enable VRRP state change traps • xstp — Enable 802.1s, 802.1w, and PVST+ state change traps The default is all trap types are sent to host. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The snmp-server host command is used with the snmp-server enable command. Use the snmpserver enable command to specify which SNMP notifications are sent globally. For a host to receive most notifications, at least one snmp-server enable command and the snmp-server host command for that host must be enabled.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command snmp-server packetsize Set the largest SNMP packet size permitted. Wen the SNMP server is receiving a request or generating a reply, use the snmpserver packetsize global configuration command. Syntax snmp-server packetsize byte-count Parameters byte-count Enter one of the following values 8, 16, 24 or 32. Packet sizes are 8000 bytes, 16000 bytes, 32000 bytes, and 64000 bytes.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
Parameters name Enter the name of the user (not to exceed 20 characters), on the host that connects to the agent. group_name Enter a text string (up to 20 characters long) as the name of the group. The following groups are created for mapping to read/write community/security-names (defaults): • v1v2creadu — maps to a community with ro permissions. • 1v2cwriteu — maps to a community rw permissions.
access-list-name ipv6 access-listname (Optional) Enter both an IPv4 and IPv6 access list name. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
3 auth md5 authpasswd Related Commands show snmp user — displays the information configured on each SNMP user name. snmp-server user (for AES128-CFB Encryption) Specify that AES128-CFB encryption algorithm needs to be used for transmission of SNMP information. The Advanced Encryption Standard (AES) Cipher Feedback (CFB) 128-bit encryption algorithm is in compliance with RFC 3826. RFCs for SNMPv3 define two authentication hash algorithms, namely, HMAC-MD5-96 and HMAC-SHA1-96.
previously set up. Otherwise, you must remove the previously configured users before you change the FIPS mode. Example Dell# snmp-server user privuser v3group v3 encrypted auth md5 9fc53d9d908118b2804fe80e3ba8763d priv aes128 d0452401a8c3ce42804fe80e3ba8763d Related Commands show snmp user — Displays the information configured on each SNMP user name. snmp-server view Configure an SNMPv3 view.
Related Commands show running-config snmp — displays the SNMP running configuration. snmp-server vrf Configures an SNMP agent to bind to a specific VRF. Syntax snmp-server vrf vrf-name To undo the SNMP agent configuration, use the no snmp-server vrf vrf-name command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate an SNMP agent with that VRF. Defaults Not Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information If the interface is expected to flap during normal usage, you could disable this command.
Version Description E-Series legacy command Related Commands show logging — displays logging settings and system messages in the internal buffer. clear logging auditlog Clears audit log. Syntax clear logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging buffered — sets the logging buffered parameters. default logging console Return the default settings for messages logged to the console. Syntax default logging console Defaults level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging monitor — sets the logging monitor parameters. terminal monitor — sends system messages to the terminal/monitor.
logging Configure an IP address or host name of a Syslog server where logging messages are sent. Multiple logging servers of both IPv4 and/or IPv6 can be configured. Syntax logging {ip-address | ipv6-address | hostname} {{udp {port}} | {tcp {port}} To disable logging, use the no logging command. Parameters ip-address Enter the IPv4 address in dotted decimal format. ipv6-address Enter the IPv6 address in the x:x:x:x::X format. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Related Commands logging on — enables the logging asynchronously to logging buffer, console, Syslog server, and terminal lines. logging trap — enables logging to the Syslog server based on severity. logging buffered Enable logging and specify which messages are logged to an internal buffer. By default, all messages are logged to the internal buffer. Syntax logging buffered [level] [size] To return to the default values, use the default logging buffered command.
Related Commands clear logging — clears the logging buffer. default logging buffered — returns the logging buffered parameters to the default setting. show logging — displays the logging setting and system messages in the internal buffer. logging console Specify which messages are logged to the console. Syntax logging console [level] To return to the default values, use the default logging console command. To disable logging to the console, use the no logging console command.
logging extended Logs security and audit events to a system log server. Syntax logging extended Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
• local0 (local use) • local1 (local use) • local2 (local use) • local3 (local use) • local4 (local use) • local5 (local use) • local6 (local use) • local7 (local use) • lpr (line printer system) • mail (mail system) • news (USENET news) • sys9 (system use) • sys10 (system use) • sys11 (system use) • sys12 (system use) • sys13 (system use) • sys14 (system use) • syslog (Syslog process) • user (user process) • uucp (Unix to Unix copy process) The default is local7.
logging on — enables logging. logging history Specify which messages are logged to the history table of the switch and the SNMP network management station (if configured). Syntax logging history level To return to the default values, use the no logging history command. Parameters level Indicate a value from 0 to 7 or enter one of the following equivalent words: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 4 or warnings.
Parameters size Indicate a value as the number of messages to be stored. The range is from 0 to 500. The default is 1 message. Defaults 1 message Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Usage Information When you use the no logging on command, messages are logged only to the console. Related Commands logging — enables logging to the Syslog server. logging buffered — sets the logging buffered parameters. logging console — sets the logging console parameters. logging monitor — sets the logging parameters for the terminal connections. logging source-interface Specify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information Syslog messages contain the IP address of the interface used to egress the router. By configuring the logging source-interface command, the Syslog packets contain the IP address of the interface configured.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When you enable logging synchronous, unsolicited messages appear between software prompts and outputs. Only the messages with a severity at or below the set level are sent to the console.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information To block a type of message parameter, set the logging trap level to a lower number. For example, to block severity messages at level 6, set the level to 5. Related Commands logging — enables the logging to another device. logging on — enables logging. logging version Displays syslog messages in a RFC 3164 or RFC 5424 format.
Parameters Command Modes Command History number (OPTIONAL) Enter the number of messages displayed in the output. The range is from 1 to 65535. history (OPTIONAL) Enter the keyword history to view only information in the Syslog history table. reverse (OPTIONAL) Enter the keyword reverse to view the Syslog messages in FIFO (first in, first out) order. summary (OPTIONAL) Enter the keyword summary to view a table showing the number of messages per type and per slot. Slots *7* and *8* represent RPMs.
Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: 1.1.10.2 (Hold time expired) Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Oct 8 09:26:25: %RPM1:RP1 %BGP-5-ADJCHANGE: 1.1.11.2 closed. Neighbor recycled Oct 8 09:26:25: %RPM1:RP1 %BGP-5-ADJCHANGE: 1.1.14.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands 1398 logging monitor — sets the logging parameters on the monitor/terminal.
53 SNMP Traps This chapter lists the traps sent by the Dell Networking operating software. Each trap is listed by the fields Message ID, Trap Type, and Trap Option. Message ID Trap Type Trap Option COLD_START SNMP COLDSTART WARM_START SNMP WARMSTART COPY_CONFIG_COMPLETE SNMP NONE SNMP LINKDOWN SNMP LINKUP SNMP AUTH EGP_NEIGHBOR_LOSS SNMP NONE OSTATE_DOWN SNMP LINKDOWN SNMP LINKUP SNMP NONE SNMP NONE SNMP NONE SNMP NONE %SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.
Message ID Trap Type Trap Option SNMP NONE SNMP NONE SNMP NONE NONE NONE ENVMON NONE ENVMON NONE ENVMON NONE CHM_CARD_PROBLEM ENVMON NONE CHM_ALARM_CUTOFF ENVMON NONE CHM_SFM_UP ENVMON NONE CHM_SFM_DOWN ENVMON NONE CHM_RPM_UP ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE %RPM0-P:CP %SNMP-4-RMON_HC_FALLING_THRESHOLD: RMON highcapacity falling threshold alarm from SNMP OID BER_ERR %IFMGR-5-BER_ERR: High Ber detected on interface : %s BER_ERR_CLR %IFMGR-5-BER_ERR_C
Message ID Trap Type Trap Option CHM_SFM_REMOVE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON FAN %TSM-5-SFM_REMOVE: Removed SFM 1 CHM_MAJ_SFM_DOWN %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down CHM_MAJ_SFM_DOWN_CLR %CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up CHM_MIN_SFM_DOWN %CHMGR-2-MINOR_SFM: MIn
Message ID Trap Type Trap Option ENVMON FAN ENVMON FAN ENVMON FAN ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is missing or down %CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan tray %d are down.
Message ID Trap Type Trap Option ENVMON NONE ENVMON NONE ENVMON NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE %MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d PORT_TEMP_MAJOR %CHMGR-1-PORT_TEMP_MAJOR: Major Alarm Interface %s shut due to high temperature PORT_TEMP_MINOR %CHMGR-1-PORT_TEMP_MINOR: Minor Alarm Interface %s temperature exceeds threshold PORT_TEMP_MAJOR_CLR %CHMGR-1-PORT_TEMP_MAJOR_CLR: Major Alarm cleared for Interface %s port tem
54 Stacking All commands in this chapter are specific to the Dell Networking operating software. You can use the commands to pre-configure a switch, so that the configuration settings are invoked when the switch is attached to other S-Series units. For information about using the S-Series stacking feature, refer to the “Stacking S-Series Switches” chapter in the Dell Networking OS Configuration Guide. CAUTION: You cannot enable stacking simultaneously with virtual link trunking (VLT).
Version Description 8.3.1.0 Added the members option. Usage Information Enabling this command keeps the failed switch in the Failed state. The switch does not reboot until it is manually rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the running-config. Related Commands show redundancy — displays the current redundancy status. redundancy force-failover stack-unit Force the standby unit in the stack to become the management unit.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Added the members option.
Example Related Commands Dell#reset stack-unit 4 Dell#00:15:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNIT_RESET: stack-unit 4 being reset 00:15:01: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 4 down - reset 00:15:01: %STKUNIT1-M:CP %IFMGR-1-DEL_PORT: Removed port: Gi 4/1-4/48, Te 4/51-4/52, 00:15:01: %STKUNIT2-S:CP %IFMGR-1-DEL_PORT: Removed port: Gi 4/1-4/48, Te 4/51-4/52, Dell#00:15:08: %S3048-ON:1 %IFAGT-5-STACK_PORT_LINK_DOWN: Changed stack port state to down: 1/49 00:15:08: %STKUNIT1-M:CP %CHMGR-2-STA
Mgmt ID: 0 Stack-unit ID: 0 Stack-unit Redundancy Role: Primary Stack-unit State: Active Stack-unit SW Version: 1-0(0-3563) Link to Peer: Down Peer Stack-unit: not present -- Stack-unit Redundancy Configuration ------------------------------------------------Primary Stack-unit: mgmt-id 0 Auto Data Sync: Full Failover Type: Hot Failover Auto reboot Stack-unit: Disabled Auto failover limit: 3 times in 60 minutes -- Stack-unit Failover Record ------------------------------------------------Failover Count: 0 La
Usage Information Version Description 9.8(0.0) Introduced on the S3048–ON and S4048–ON. 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. The following describes the show system stack-ports command shown in the following example. Field Description Topology Lists the topology of stack ports connected: Ring, Daisy chain, or Standalone. Interface The unit/port ID of the connected stack port on this unit.
3/27/1 3/28/1 Example (Topology) Related Commands 10 10 up up down down Dell#show system stack-port topology Topology: Daisy chain Interface Connection --------------------1/25 3/25 1/26 1/27 1/28 3/25 1/25 3/26 3/27 3/28 • reset stack-unit – resets the designated stack member. • show hardware stack-unit – displays the data plane or management plane input and output statistics of the designated component of the designated stack member.
Related Commands • reload – reboots Dell Networking OS. stack-unit provision Preconfigure a logical stacking ID of a switch that joins the stack. This is an optional command that is executed on the management unit. Syntax Parameters stack-unit [stack-number] provision {S4810|S4820T|S6000|Z9000} stack-unit Enter a stack member identifier of the switch that you want to add to the stack. S4810|S4820T| S6000|Z9000 Enter the model identifier of the switch to be added as a stack member.
stack-group-id Enter the stack group ID. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S3048–ON. 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8.(0.0) Introduced on the S3048-ON and S3048–ON. 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
55 Storm Control The Dell Networking operating software storm control feature allows you to limit or suppress traffic during a traffic storm (Broadcast/Unknown Unicast Rate Limiting or Multicast on the C-Series and S-Series). Storm control is supported on Dell Networking OS. Important Points to Remember • Interface commands can only be applied on physical interfaces (virtual local area networks [VLANs] and link aggregation group [LAG] interfaces are not supported).
Defaults Command Modes Command History • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. storm-control multicast (Configuration) Configure the packets per second (pps) of multicast traffic allowed into the C-Series and S-Series networks only.
storm-control multicast (Interface) Configure the percentage of multicast traffic allowed on an C-Series or S-Series interface (ingress only) network only. Syntax storm-control multicast packets_per_second in To disable multicast storm control on the interface, use the no storm-control multicast packets_per_second in command. Parameters packets_per_secon d in Enter the packets per second of broadcast traffic allowed into the network. The range is from 0 to 33554368.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 1422 Storm Control Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
56 Spanning Tree Protocol (STP) The commands in this chapter configure and monitor the IEEE 802.1d spanning tree protocol (STP) and are supported on the Dell Networking switch/routing platform. bridge-priority Set the bridge priority of the switch in an IEEE 802.1D spanning tree. Syntax bridge-priority {priority-value | primary | secondary} To return to the default value, use the no bridge-priority command. Parameters priority-value Enter a number as the bridge priority value.
bpdu-destination-mac-address Use the Provider Bridge Group address in Spanning Tree or GVRP PDUs. Syntax bpdu-destination-mac-address [stp | gvrp] provider-bridge-group Parameters xstp Force STP, RSTP, and MSTP to use the Provider Bridge Group address as the destination MAC address in its BPDUs. gvrp Forces GVRP to use the Provider Bridge GVRP Address as the destination MAC address in its PDUs. Defaults The destination MAC address for BPDUs is the Bridge Group Address.
root (OPTIONAL) Enter the keyword root to debug STP root transactions. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced protocol spanning-tree — enters SPANNING TREE mode on the switch. disable Disable the spanning tree protocol globally on the switch. Syntax disable To enable Spanning Tree Protocol, use the no disable command.
forward-delay The amount of time the interface waits in the Listening state and the Learning state before transitioning to the Forwarding state. Syntax forward-delay seconds To return to the default setting, use the no forward-delay command. Parameters seconds Enter the number of seconds the Dell Networking OS waits before transitioning STP to the Forwarding state. The range is from 4 to 30. The default is 15 seconds.
Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state. hello-time — changes the time interval between BPDUs. protocol spanning-tree To enable and configure the spanning tree group, enter SPANNING TREE mode.
Example Dell(conf)#protocol spanning-tree 0 Dell(config-stp)# Related Commands disable — disables spanning tree group 0. To enable spanning tree group 0, use the no disable command. show config Display the current configuration for the mode. Only non-default values display. Syntax show config Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
brief (OPTIONAL) Enter the keyword brief to display a synopsis of the spanning tree group configuration information. guard (OPTIONAL) Enter the keyword guard to display the type of guard enabled on an STP interface and the current port state. interface interface (OPTIONAL) Enter the keyword interface and the type slot/port of the interface you want displayed. Type slot/port options are the following: • For a Port Channel interface, enter the keywords port-channel then a number.
Example Field Description “We are...” States whether this bridge is the root bridge for the STG. “Current root...” Lists the bridge priority and MAC address for the root bridge. “Topology flag...” States whether the topology flag and the detected flag were set. “Number of...” Displays the number of topology changes, the time of the last topology change, and on what interface the topology change occurred.
Port 28 (GigabitEthernet 1/3) is Forwarding Port path cost 4, Port priority 8, Port Identifier 8.28 Designated root has priority 32768, address 0001.e800.0a56 Designated bridge has priority 32768, address 0001.e800.0a56 Designated port id is 8.
Parameters stp-id Enter the STP instance ID. The range is 0. cost cost Enter the keyword cost then a number as the cost. The range is from 1 to 65535. The defaults are: • 1-Gigabit Ethernet interface = 4. • 10-Gigabit Ethernet interface = 2. • Port Channel interface with 100 Mb/s Ethernet = 18. • Port Channel interface with 1 Gigabit Ethernet = 3. • Port Channel interface with 10 Gigabit Ethernet = 1.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. If you enable portfast bpduguard on an interface and the interface receives a BPDU, the software disables the interface and sends a message stating that fact. The port is in ERR_DISABLE mode, yet appears in the show interface commands as enabled. If you do not enable shutdown-onviolation, BPDUs are still sent to the RPM CPU.
57 System Time and Date The commands in this chapter configure time values on the system, either using the Dell Networking operating software, or the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the “Network Time Protocol” section of the Management chapter in the Dell Networking OS Configuration Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
start-day Enter the name of the day that you want daylight saving time to begin. Use English three letter abbreviations; for example, Sun, Sat, Mon, and so on. The range is from Sun to Sat. start-month Enter the name of one of the 12 months in English. start-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm.
Related Commands clock summer-time date — sets a date (and time zone) on which to convert the switch to daylight saving time on a one-time basis. show clock — displays the current clock settings. clock timezone Configure a timezone for the switch. Syntax clock timezone timezone-name offset To delete a timezone configuration, use the no clock timezone command. Parameters timezone-name Enter the name of the timezone. You cannot use spaces.
debug ntp Display network time protocol (NTP) transactions and protocol messages for troubleshooting. Syntax debug ntp {adjust | all | authentication | events | loopfilter | packets | select | sync} To disable debugging of NTP transactions, use the no debug ntp {adjust | all | authentication | events | loopfilter | packets | select | sync} command. Parameters adjust Enter the keyword adjust to display information on NTP clock adjustments.
ntp authenticate Enable authentication of NTP traffic between the switch and the NTP time serving hosts. Syntax ntp authenticate To disable NTP authentication, use the no ntp authentication command. Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Defaults NTP authentication is not configured by default. If you do not specify the option [0 | 7], 0 is selected by default. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.
ntp multicast client To receive NTP information from the network via multicast, configure the switch. Syntax ntp multicast client [multicast-address] To disable multicast reception, use the no ntp multicast client [multicast-address] command. Parameters multicast-address (OPTIONAL) Enter a multicast address. Enter either an IPv4 address in dotted decimal format or an IPv6 address in X:X:X:X::X format. If you do not enter a multicast address, the address: • 224.0.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Introduced on the S4810, S4820T, S5000, S6000, Z9000, and Z9500. ntp server Configure an NTP time-serving host.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added IPv6 support. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. You can configure multiple time-serving hosts . From these time-serving hosts, the Dell Networking OS chooses one NTP host with which to synchronize. To determine which server was selected, use the show ntp associations command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. ntp trusted-key Set a key to authenticate the system to which NTP synchronizes. Syntax ntp trusted-key number To delete the key, use the no ntp trusted-key number command. Parameters number Enter a number as the trusted key ID.
show clock Display the current clock settings. Syntax show clock [detail] Parameters Command Modes Command History detail • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword detail to view the source information of the clock. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Example Dell#show ntp associations remote ref clock st when poll reach delay offset disp ============================================================= 10.10.120.5 0.0.0.0 16 - 256 0 0.00 0.000 16000.0 *172.16.1.33 127.127.1.0 11 6 16 377 -0.08 -1499.9 104.16 172.31.1.33 0.0.0.0 16 - 256 0 0.00 0.000 16000.0 192.200.0.2 0.0.0.0 16 - 256 0 0.00 0.000 16000.0 * master (synced), # master (unsynced), + selected, - candidate Dell# Related Commands show ntp status — displays the current NTP status.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
58 Tunneling Tunneling is supported on Dell Networking OS. ip unnumbered Configure a tunnel interface to operate without a unique IPv4 address and select the interface from which the tunnel borrows its address. Syntax ip unnumbered {interface-type slot/port} To set the tunnel back to default logical address use the no ip unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv6 address.
ipv6 unnumbered Configure a tunnel interface to operate without a unique IPv6 address and select the interface from which the tunnel borrows its address. Syntax ipv6 unnumbered {interface-type interface-number} To set the tunnel back to default logical address use the no ipv6 unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv4 address. Parameters interface-type interface-number Defaults None.
ipv6–address Enter the source IPv6 address in X:X:X:X::X format. mask (OPTIONAL) Enter a network mask in /prefix format (/x) or A.B.C.D to match a range of remote addresses. The default mask is /32 for IPv4 addresses and /128 for IPv6 addresses, which match only the specified address. Defaults If you do not configure tunnel allow remote , all traffic which is destined to tunnel source address is decapsulated. Command Modes INTERFACE TUNNEL Command History Usage Information Version Description 9.
Usage Information The tunnel interface is inoperable without a valid tunnel destination address for the configured Tunnel mode. To establish a logical tunnel to the particular destination address, use the destination address of the outer tunnel header. If you configure a tunnel interface or source address, the tunnel destination must be compatible. tunnel dscp Configure the method to set the DSCP in the outer tunnel header.
tunnel flow-label Configure the method to set the IPv6 flow label value in the outer tunnel header. Syntax tunnel flow-label value To return to the default value of 0, use the no tunnel flow-label value command. Parameters value Enter a value to set the IPv6 flow label value in the tunnel header. The range is from 0 to 1048575. The default value is 0.
tunnel keepalive Configure the tunnel keepalive target, interval and attempts. Syntax tunnel keepalive {ip-address | ipv6-address}[interval {seconds}] [attempts {count | unlimited}] To disable the tunnel keepalive probes use the no tunnel keepalive command. Parameters ip-address ipv6 address Enter the IPv4 or IPv6 address of the peer to which the keepalive probes will be sent.
Syntax tunnel mode {ipip | ipv6 | ipv6ip}[decapsulate-any] To disable an active tunnel interface, use the no tunnel mode command. Parameters ipip Enable tunnel in RFC 2003 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv4 tunnel. ipv6 Enable tunnel in RFC 2473 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv6 tunnel. ipv6ip Enable tunnel in RFC 4213 mode and encapsulate IPv6 datagrams inside an IPv4 tunnel.
interface-typenumber anylocal • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
59 Uplink Failure Detection (UFD) Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if you use this with NIC teaming, automatic recovery from a failed link. clear ufd-disable Re-enable one or more downstream interfaces on the switch/router that are in a UFD-Disabled Error state so that an interface can send and receive traffic.
Related Commands • downstream — assigns a port or port-channel to the uplink-state group as a downstream interface. • uplink-state-group — creates an uplink-state group and enables the tracking of upstream links. debug uplink-state-group Enable debug messages for events related to a specified uplink-state group or all groups. S3048–ON Syntax debug uplink-state-group [group-id] To turn off debugging event messages, enter the no debug uplink-state-group [group-id] command.
Defaults none Command Modes UPLINK-STATE-GROUP Version 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux (PMUX) mode only. Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50. • downstream — assigns a port or port-channel to the uplink-state group as a downstream interface. • uplink-state-group — creates an uplink-state group and enables the tracking of upstream links. downstream disable links Configure the number of downstream links in the uplink-state group that are disabled if one upstream link in an uplink-state group goes down.
enable Enable uplink state group tracking for a specific UFD group. Syntax enable To disable upstream-link tracking without deleting the uplink-state group, use the no enable command. Defaults Upstream-link tracking is automatically enabled in an uplink-state group. Command Modes UPLINK-STATE-GROUP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50.
Parameters group-id Enter the ID number of an uplink-state group. The range is from 1 to 16. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(0.
To delete an uplink-state group, use the no upstream interface command.
60 VLAN Stacking With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can “stack” VLANs into one tunnel and switch them through the network transparently. The Dell Networking operating software supports this feature on Dell Networking OS. For more information about basic VLAN commands, refer to the Virtual LAN (VLAN) Commands section in the Layer 2 chapter.
• Red: Lowest priority packets that are always dropped (regardless of congestion status). Defaults Disabled; Packets with an unmapped DEI value are colored green. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the C-Series and S-Series. You must first enable DEI for this configuration to take effect. member Assign a stackable VLAN access or trunk port to a VLAN.
Usage Information You must enable the stackable VLAN (using the vlan-stack compatible command) on the VLAN prior to adding a member to the VLAN. Related Commands vlan-stack compatible — enables stackable VLAN on a VLAN. stack-unit stack-group Configure a stacking group specified by an ID. Syntax Parameters [no] stack-unit unit-id stack-group stack-group-id unit-id Enter the stack unit ID. stack-group-id Enter the stack group ID. The range is from 0 to 16.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series. E-Series original Command Usage Information Prior to disabling the stackable VLAN feature, remove the members. To view the stackable VLANs, use the show vlan command in EXEC Privilege mode. Stackable VLANs contain members, designated by the M in the Q column of the command output.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.1.
Version Description E-Series original Command Usage Information For specific interoperability limitations regarding the S-Tag TPID, refer to the Dell Networking OS Configuration Guide. The four characters you enter in the CLI for number are interpreted, as shown in the following table. Related Commands Number Resulting TPID 1 0x0001 10 0x0010 81 0x0081 8100 0x8100 portmode hybrid — sets a port (physical ports only) to accept both tagged and untagged frames.
Version Description 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 7.8.1.0 Functionality augmented for C-Series and S-Series to enable multi-purpose use of the port. 7.7.1.0 Functionality augmented for E-Series to enable multi-purpose use of the port. 7.6.1.0 Introduced on the C-Series and S-Series.
G - GVRP tagged, M - Vlan-stack NUM Status Description * 1 Inactive 20 Active 100 Active Dell(conf-if-vl-20)# Example 2 Q Ports T Gi 1/42 M Gi 1/42 Dell(config)#vlan-stack protocol-type 88A8 Dell(config)#interface gigabitethernet 3/10 Dell(conf-if-gi-3/10)#no shutdown Dell(conf-if-gi-3/10)#switchport Dell(conf-if-gi-3/10)#vlan-stack access Dell(conf-if-gi-3/10)#exit Dell(config)#interface Gigabitethernet 5/1 Dell(conf-if-gi-5/1)#no shutdown Dell(conf-if-gi-5/1)#portmode hybrid Dell(conf-if-gi-5/1)#switchp
61 Virtual Routing and Forwarding (VRF) Virtual Routing and Forwarding (VRF) allows multiple instances of a routing table to co-exist on the same router at the same time. ip vrf Creates a customer VRF. Syntax ip vrf {vrf-name | management} [vrf_id] To delete a customer VRF, use the no ip vrf {vrf-name | management} [vrf_id] command. Parameters vrf-name Enter the name of the VRF that you want to create. management Use this keyword when you want to create the management VRF.
ip http vrf Configures an HTTP client with a VRF that is used to connect to the HTTP server. Syntax ip http vrf {management | vrf-name} To undo the HTTP client configuration, use the ip http vrf command. Parameters management Enter the keyword management for configuring the management VRF that uses an HTTP client. vrf-name Enter the name of the VRF for configuring a nondefault that uses an HTTP client.
Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series. Use this command to specify a descriptive name for a VRF. ip vrf forwarding Enables you to attach an interface to a VRF. Syntax ip vrf forwarding {vrf-name | management} To delete an interface associated with a configured VRF, use the no ip vrf forwarding {vrf-name | management} command.
Example Dell#configure terminal Dell(conf)#ip vrf red Dell(conf-vrf)#description "Red Network" Dell(conf-vrf)#show config ! ip vrf red 4 description "Red Network" Dell(conf-vrf)# Dell(conf-if-gi-1/45)#int gi 1/46 Dell(conf-if-gi-1/46)#no shut Dell(conf-if-gi-1/46)#ip vrf forwarding red Dell(conf-if-gi-1/46)#ip add 100.1.1.1/24 Dell(conf-if-gi-1/46)# Dell(conf-if-gi-1/46)# Dell(conf-if-gi-1/46)# Dell(conf-if-gi-1/46)#show config ! interface GigabitEthernet 1/46 ip vrf forwarding red ip address 100.1.1.
configure at most one route-export per VRF as only one set of routes can be exposed for leaking. However, you can configure multiple route-import targets because a VRF can accept routes from multiple VRFs. You can expose a unique set of routes from the Source VRF for Leaking to other VRFs. When two VRFs leak or export routes, there is no option to discretely filter leaked routes from each source VRF. Meaning, you cannot import one set of routes from one VRF and another set of routes from another VRF.
ipv6 route-export Enables route leaking between VRFs. Exports or shares IPv6 routes corresponding to one VRF with other non-default VRFs. Syntax Parameters Defaults ipv6 route-export tag [route-map-name] route-export Enter the keyword route-export to leak or share routes between VRFs. tag Enter a tag (ASN number) as the export route target to expose routes to other VRFs. This tag acts as an identifier for exported routes.
Parameters route-import Enter the keyword route-import to import IPv6 routes into the VRF. tag Enter a tag (ASN number) to specify an import route target for importing routes from another VRF. To import leaked routes from another VRF, you must use the same ASN number that is specified as the export route target at the source VRF. route-map-name Enter the name of the route-map to filter the imported routes. NOTE: You must use the route-map attribute while importing routes from the global RTM.
Command History Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, and Z9500. You can specify the matching criteria only after defining a route-map. Before using this command, you must enter the route map mode using the route-map route-map-name command. The match criteria that you specify is associated with the route-map that you define.
To delete the association between a management port and a management VRF, use the no interface management command. Defaults None. Command Modes VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON and Z9500. 9.4(0.0) Introduced on the S–Series. If the maximum route limit is not specified for a VRF, then it has unlimited space that extends to the maximum number of entries allowed for the system. This command is not applicable to the default and management VRFs.
management 64 FTOS#show ip vrf test1 VRF-Name VRF-ID Interfaces test1 1 Gi 1/14,16-17 show run vrf Displays configuration information corresponding to all the VRFs in the system. Syntax show run vrf vrf-name Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege Enter the keyword vrf and then the name of the VRF.. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
62 VLT Proxy Gateway The Virtual link trucking (VLT) proxy gateway feature allows a VLT domain to locally terminate and route L3 packets that are destined to a Layer 3 (L3) end point in another VLT domain. Enable the VLT proxy gateway using the link layer discover protocol (LLDP) method or the static configuration. For more information, refer to Dell Networking OS Command Line Reference Guide. proxy-gateway lldp Enables the proxy-gateway feature using LLDP protocol.
Command History Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000. Usage Information When proxy-gateway static configuration is added, the setting is saved in the Layer 2 module. When you remove the static proxy gateway configuration, each proxy-gateway static mac configured is deleted from the Layer 2 module.
Dell(conf-vlt-domain-proxy-gw-static)#remote-mac-address 00:01:e8:06:95:ac exclude-vlan 3 peer-domain-link port-channel exclude-vlan Configure the VLT port channel, which is connected to remote VLT domain for Proxy Gateway and configure the VLANs that needs to be excluded from VLT Proxy Gateway. S3048–ON Syntax Parameters [no] peer-domain-link port-channel interface-identifier exclude-vlan vlanrange port-channel Configure the proxy-gateway interface port-channel. Port channel range is from 1 to 128.
proxy-gateway peer-timeout Enables the VLT node to timeout the transmission of peer’s mac address, when the VLT peer is down. S3048–ON Syntax [no] peer-timeout value Parameters Command Modes Command History value Enter the timeout value in seconds. The range is from 1 to 65535. VLT DOMAIN PROXY GW LLDP Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Removed the default value on the S-Series and Z-Series. 9.4(0.
show vlt-proxy-gateway Display the VLT proxy gateway configuration. S3048–ON Syntax Parameters Command Modes show vlt-proxy-gateway [info] {lldp | static} lldp Display details about the LLDP VLT proxy gateway configuration static Display details about the static VLT proxy gateway configuration EXEC EXEC Privilege Command History Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.4(0.
Po 55 00:01:e8:8b:1c:c0 3,7-8 1496 VLT Proxy Gateway
63 Virtual Link Trunking (VLT) Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network core. VLT eliminates the requirement for Spanning Tree protocols by allowing link aggregation group (LAG) terminations on two separate distribution or core switches, and by supporting a loop-free topology.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Added multicast and ndp parameters. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
Usage Information Related Commands Version Description 8.3.19.0 Introduced on the S8420T. 8.3.12.0 Introduced on the S4810. To delay the system from bringing up the VLT port for a brief period to allow IGMP Snooping and Layer 3 routing protocols to converge, use the delay-restore parameter. Use this feature: • after a VLT device is reloaded. • if the Peer VLT device was up at the time the VLTi link failed to the time when it was restored.
vlt Force all VLT LACP members to become switchports. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
To restore the default value, use the no multicast peer-routing timeout command. Parameters value Enter the timeout value in seconds. The range is from 1 to 1200. The default is 150. Command Modes VLT DOMAIN (conf-vlt-domain) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support for the peer-down-vlan parameter. 8.3.8.0 Introduced on the S4810. To configure the VLAN from where the VLT peer forwards packets received over the VLTi from an adjacent VLT peer that is down, use the peer-down-vlan parameter.
To restore the default value, use the no peer-routing-timeout command. Parameters value Enter the timeout value in seconds. The range is from 1 to 65535. The default value is infinity. Command Modes VLT DOMAIN (conf-vlt-domain) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. After you configure the VLT domain on each peer switch on both sides of the interconnect trunk, by default, the Dell Networking OS software elects a primary and secondary VLT peer device.
Remote System MAC address Remote system version Delay-Restore timer : 00:01:e8:8a:e9:76 : 6(3) : 90 seconds Delay-Restore Abort Threshold Peer-Routing Peer-Routing-Timeout timer Multicast peer-routing timeout Dell# : 60 seconds : Disabled : 0 seconds : 150 seconds show vlt backup-link Displays information on the backup link operation. Syntax show vlt backup-link Default Not configured. Command Modes EXEC Command History This guide is platform-specific.
show vlt counters Displays the counter information. Syntax Parameters show vlt counters [arp| igmp-snoop | interface | mac | ndp] arp Enter the keyword arp to display the ARP counter information for the VLT. igmp-snoop Enter the keywords igmp-snoop to display the igmp-snooping counter information for the VLT. interface Enter the keyword interface to display the interface counter information for the VLT. mac Enter the keyword mac to display the MAC address counter information for the VLT.
IGMP MRouter Vlans count : 0 IGMP Mcast Groups count : 5 Dell# show vlt counter igmp-snoop interface port-channel 100 VLT Port-ID: 100 IGMP Counter ----------------------IGMP MRouter Vlans count : 1 IGMP Mcast Groups count : 0 Ve Example (NDP and Non-VLT ARP) Dell#show vlt counters Total VLT Counters ------------------L2 Total MAC-Address Count: Total Arp Entries Learnt : Total Arp Entries Synced : Total Non-VLT Arp entries Learnt: Total Non-VLT Arp Entries Synced IGMP MRouter Vlans count : IGMP Mcast Grou
show vlt inconsistency Display run-time inconsistencies in the incoming interface (IIF) for spanned multicast routes. Syntax show vlt inconsistency ip mroute Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.
Example Version Description 9.5(0.1) Introduced on the Z9500. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000.
0x4100 0x8100 VLT-VLAN config --------------Local Lag --------128 Peer Lag -------128 Local VLANs ----------4094 Peer VLANs ---------100 Dell# show vlt role Displays the VLT peer status, role of the local VLT switch, VLT system MAC address and system priority, and the MAC address and priority of the local VLT device. Syntax show vlt role Default Not configured. Command Modes EXEC Command History This guide is platform-specific.
show vlt statistics Displays statistics on VLT operations. Syntax show vlt statistics [arp | domain | igmp-snoop | mac | multicast | ndp] Parameters domain Display the VLT statistics for the domain. multicast Display the VLT statistics for multicast. mac Display the VLT statistics for the MAC address. arp Display the VLT statistics for ARP. igmp-snoop Display the VLT statistics for IGMP snooping. ndp Display the VLT statistics for NDP. Default Not configured.
L2 L2 L2 L2 L2 Info Pkts Rcvd:3, L2 Mac-sync Pkts Rcvd:2 Reg Request sent:1 Reg Request rcvd:2 Reg Response sent:1 Reg Response rcvd:1 VLT Igmp-Snooping Statistics ------------------------------IGMP Info Pkts sent: 4 IGMP Info Pkts Rcvd: 1 IGMP Reg Request sent: 1 IGMP Reg Request rcvd: 2 IGMP Reg Response sent: 1 IGMP Reg Response rcvd: 1 IGMP PDU Tunnel Pkt sent: 5 IGMP PDU Tunnel Pkt rcvd: 10 IGMP Tunnel PDUs sent: 10 IGMP Tunnel PDUs rcvd: 19 VLT Multicast Statistics ------------------------------Info
Example Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
To reconfigure the default MAC address for the domain by entering a new MAC address in the format nn:nn:nn:nn:nn:nn, use the system-mac command. You must also reconfigure the same MAC address on the VLT peer switch. unit-id Explicitly configure the default unit ID of a VLT peer switch. Syntax Parameters unit-id [0 | 1] 0|1 Configure the default unit ID of a VLT peer switch. Enter 0 for the first peer or enter 1 for the second peer.
vlt domain Enable VLT on a switch, configure a VLT domain, and enter VLT-domain configuration mode. Syntax vlt domain domain-id Parameters domain-id Enter the Domain ID number. Configure the same domain ID on the peer switch. The range of domain IDs is from 1 to 1000. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. show vlt private-vlan Display the private VLAN (PVLAN) associated with the VLT LAG for VLT peer nodes.
64 Virtual Router Redundancy Protocol (VRRP) Virtual router redundancy protocol (VRRP) is supported by the Dell Networking operating system on Dell Networking OS. IPv4 VRRP Commands The following are IPv4 VRRP commands. advertise-interval Set the time interval between VRRP advertisements. Syntax advertise-interval {seconds | centisecs centisecs } To return to the default settings, use the no advertise-interval command. Parameters seconds Enter a number of seconds. The range is from 1 to 255.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. Dell Networking recommends keeping the default setting for this command. If you do change the time interval between VRRP advertisements on one router, change it on all routers. authentication-type Enable authentication of VRRP data exchanges. Syntax authentication-type simple [encryption-type] password To delete an authentication type and password, use the no authentication-type command.
clear counters vrrp Clear the counters maintained on VRRP operations. Syntax clear counters vrrp [vrrp-id] [ipv6] [vrf vrf-name] Parameters vrrp-id (OPTIONAL) Enter the number of the VRRP group ID. The range is from 1 to 255. ipv6 (OPTIONAL) Enter the keyword ipv6 to clear counters from the IPv6 VRRP group. vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear counters that are maintained on the VRRP operations corresponding to that VRF.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094. vrrp-id (OPTIONAL) Enter a number from 1 to 255 as the VRRP group ID. all Enter the keyword all to enable debugging of all VRRP groups. bfd Enter the keyword bfd to enable debugging of VRRP BFD interactions. database Enter the keyword database to enable debugging of configuration changes.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.
hold-time Specify a delay (in seconds) before a switch becomes the MASTER virtual router. By delaying the initialization of the VRRP MASTER, the new switch can stabilize its routing tables. Syntax hold-time {seconds | centisecs centisecs} To return to the default value, use the no hold-time command. Parameters seconds Enter the number of seconds. The range is from 0 to 65535. The default is zero (0) seconds.
Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. To guarantee that a VRRP group becomes MASTER, configure the VRRP group’s virtual address with same IP address as the interface’s primary IP address and change the priority of the VRRP group to 255. If you set the priority command to 255 and the virtual-address is not equal to the interface’s primary IP address, an error message appears. show config View the non-default VRRP configuration.
show vrrp View the VRRP groups that are active. If no VRRP groups are active, the Dell Networking OS returns No Active VRRP group. Syntax show vrrp [vrrp-id] [vrf vrf-name] [interface] [brief][ipv6] Parameters Command Modes Command History vrrp-id (OPTIONAL) Enter the Virtual Router Identifier for the VRRP group to view only that group. The range is from 1 to 255. vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view active VRRP groups corresponding to that VRF.
Item Description Interface Lists the interface type, slot and port on which the VRRP group is configured. Grp Displays the VRRP group ID. Pri Displays the priority value assigned to the interface. If the track command is configured to track that interface and the interface is disabled, the cost is subtracted from the priority value assigned to the interface. Pre States whether preempt is enabled on the interface. State • Y = Preempt is enabled. • N = Preempt is not enabled.
Item Example Description • Adv rcvd displays the number of VRRP advertisements received on the interface. • Adv sent displays the number of VRRP advertisements sent on the interface. • Gratuitous ARP sent displays the number of gratuitous ARPs sent. Virtual MAC address Displays the virtual MAC address of the VRRP group. Virtual IP address Displays the virtual IP address of the VRRP router to which the interface is connected. Authentication:...
priority-cost Defaults priority cost = 10 Command Modes VRRP Command History Usage Information • For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For Port Channel interface types, enter the keywords port-channel then a number.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
Usage Information Related Command Version Description 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. This command applies to a single interface. When used with the vrrp delay reload CLI, the later timer rules the VRRP enabling. For example, if vrrp delay reload is 600 and the vrrp delay minimum is 300: • When the system reloads, VRRP waits 600 seconds (10 minutes) to bring up VRRP on all interfaces that are up and configured for VRRP.
Save the configuration and reload the system for the delay timers to take effect. Related Command vrrp delay minimum — sets the delay time for VRRP initialization after a line card reboot. vrrp-group Assign a VRRP ID to an interface. You can configure up to 12 VRRP groups per interface. Syntax vrrp-group vrrp-id Parameters vrrp-id Enter a number as the group ID. The range is from 1 to 255. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
both Enter the both keyword for in-service migration from VRRP version 2 to VRRP version 3. Defaults 2 Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000-ON.
• preempt • priority • show config • virtual-address clear counters vrrp ipv6 Clear the counters recorded for IPv6 VRRP groups. Syntax clear counters vrrp ipv6 [vrid | vrf vrf-name] Parameters vrid (OPTIONAL) Enter the number of an IPv6 VRRP group. The range is from 1 to 255. vrf vrf-name (OPTIONAL) Enter the name of a VRF instance (32 characters maximum) to clear the counters of all IPv6 VRRP groups in the specified VRF.
bfd Enter the keyword bfd to enable debugging of all VFFP BFD interactions. database Enter the keyword database to display changes related to group, prefix, and interface entries in the VRRP table. packets Enter the keyword packets to enable debugging of VRRP control packets. state Enter the keyword state to enable debugging of VRRP state changes timer Enter the keyword timer to enable debugging of the VRRP timer. Command Modes EXEC Privilege Command History This guide is platform-specific.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S3048-ON and S4048-ON. 9.2(1.0) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.3.2.
Example Line Beginning with Description Tracking states... Displays information on the tracked interfaces or objects configured for a VRRP group (track command), including: • UP or DOWN state of the tracked interface or object (Up or Dn). • Interface type and slot/port or object number, description, and time since the last change in the state of the tracked object. • Cost to be subtracted from the VRRP group priority if the state of the tracked interface/object goes DOWN.
Usage Information The VRRP group only becomes active and sends VRRP packets when a link-local virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets. • When VRF microcode is not loaded in CAM, the VRID for a VRRP group is the same as the VRID number configured with the vrrp-group or vrrp-ipv6-group command.