Service Manual

Version Description
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
6.2.1.1 Introduced on the E-Series.
Usage Information sFlow is disabled by default. In addition to this command, sFlow needs to be enable on individual interfaces
where sFlow sampling is desired.
Related Commands sow enable (Interface) — enables sFlow on interfaces.
sow ingress-enable
Enable sFlow ingress on interfaces.
Syntax
sflow ingress-enable
To disable sFlow, use the no sflow ingress enable command.
Defaults Disabled.
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.7(0.0) Introduced on the S-Series, Z-Series, and MXL switch.
Usage Information When you enable ingress sFlow on an interface, ow sampling is done on any incoming trac.
NOTE: After a physical port is a member of a LAG, it inherits the sFlow conguration from the LAG
port.
Related Commands sow enable (Global) — turns sFlow globally.
sow extended-switch enable
Enable packing information on a switch only.
Syntax
sflow extended-switch enable
To disable packing information, use the no sflow extended-switch [enable] command.
Parameters
enable Enter the keyword enable to enable global extended information.
sFlow