Service Manual

Version Description
9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-
Mux (PMUX) mode only.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.4.2.3 Introduced on the S-Series S50.
Example
Dell#show running-config uplink-state-group
!
no enable
uplink state track 1
downstream GigabitEthernet 1/2,4,6,11-19
upstream TengigabitEthernet 1/49, 50
upstream PortChannel 1
!
uplink state track 2
downstream GigabitEthernet 1/1,3,5,7-10
upstream TengigabitEthernet 1/51,52
Related Commands
show uplink-state-group — displays the status information on a specied uplink-state group or all
groups.
uplink-state-group — creates an uplink-state group and enables the tracking of upstream links.
show uplink-state-group
Display status information on a specied uplink-state group or all groups.
Syntax
show uplink-state-group [group-id] [detail]
Parameters
group-id Displays status information on a specied uplink-state group or all groups. The valid
group-id values are from 1 to 16.
detail Displays additional status information on the upstream and downstream interfaces
in each group
Defaults none
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-
Mux (PMUX) mode only.
1466