interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes
at which ACL logs must be generated. The threshold range is from 1 to 10 minutes.
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the trac
that you want to monitor and the ACL in which you are creating the rule is applied
to the monitored interface.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is ve minutes. By default, ow-based monitoring is
not enabled.
Command Modes CONFIGURATION-STANDARD-ACCESS-LIST
Command History
Version Description
9.7(0.0) Introduced on the S6000–ON.
9.4(0.0) Added support for ow-based monitoring on the S4810, S4820T, S6000, and
Z9000 platforms.
9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
Usage Information
When the congured maximum threshold is exceeded, generation of logs is stopped. When the interval at
which ACL logs are congured to be recorded expires, the subsequent, fresh interval timer is started and the
packet count for that new interval commences from zero. If ACL logging was stopped previously because
the congured threshold is exceeded, it is re-enabled for this new interval.
If ACL logging is stopped because the congured threshold is exceeded, it is re-enabled after the logging
interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and
MAC ACLs. You can congure ACL logging only on ACLs that are applied to ingress interfaces; you cannot
enable logging for ACLs that are associated with egress interfaces.
You can activate ow-based monitoring for a monitoring session by entering theflow-based enable
command in the Monitor Session mode. When you enable this capability, trac with particular ows that are
traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in
both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only
specied trac instead all trac on the interface. This feature is particularly useful when looking for
malicious trac. It is available for Layer 2 and Layer 3 ingress and egress trac. You may specify trac using
standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination
port is the monitoring port (MG).
Related Commands
deny — Assigns a IP ACL lter to deny IP packets.
ip access-list standard — Creates a standard ACL.
284