Service Manual
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
7.5.1.0 Introduced on the C-Series.
Usage Information When you insert or remove a secondary RPM with logical SFM, the system must add or remove the
backplane links to the switch fabric trunk. To avoid trac disruption, use this command when you insert the
secondary RPM. When you execute this command, the logical SFM on the standby RPM is immediately
taken oine and the SFM state is set as “standby”.
NOTE: This command could aect trac when taking the secondary SFM oine.
Example
Dell#show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
--------------------------------------
0 active
1 active
Dell#configure
Dell(conf)#redundancy sfm standby
Taking secondary SFM offline...
!
Dell(conf)#do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
-----------------------------------------
0 active
1 standby
Dell(conf)#no redundancy sfm
Taking secondary SFM online...
!
10Dell(conf)#do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
-------------------------------------------
0 active
1 active
redundancy synchronize
Manually synchronize data once between the Master and Stand-by stack units.
Syntax
redundancy synchronize [full]
570
High Availability (HA)