Service Manual

Each boot path variable (primary_boot, secondary_boot, and default_boot) is further split into the following
three independent variables:
primary_server, primary_le, and primary_type
secondary_server, secondary_le, and secondary_type
default_server, default_le, and default_type
NOTE: For information on the default values that these variables take, refer to the Restoring
Factory Default Environment Variables
section in the
Dell Networking OS Conguration guide.
Example (all stack
units)
Dell#restore factory-defaults stack-unit all clear-all
**************************************************************
* Warning - Restoring factory defaults will delete the existing *
* startup-config and all persistent settings (stacking, fanout, etc.)*
* All the units in the stack will be split into standalone units. *
* After restoration the unit(s) will be powercycled immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
0 Success Success
1 Success Success
2 Success Success
3 Not present
4 Not present
5 Not present
Power-cycling the unit(s).
Dell#
Example (single
stack)
Dell#restore factory-defaults stack-unit 0 clear-all
**************************************************************
* Warning - Restoring factory defaults will delete the existing *
* startup-config and all persistent settings (stacking, fanout, etc.)*
* After restoration the unit(s) will be powercycled immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
0 Success Success
Power-cycling the unit(s).
Dell#
Example (NvRAM all
stack units)
Dell#restore factory-defaults stack-unit all nvram
**************************************************************
* Warning - Restoring factory defaults will delete the existing *
* persistent settings (stacking, fanout, etc.) *
* All the units in the stack will be split into standalone units. *
* After restoration the unit(s) will be powercycled immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
0 Success
1 Success
2 Success
3 Not present
4 Not present
5 Not present
File Management