Service Manual
Each boot path variable (primary_boot, secondary_boot, and default_boot) is further split into the following
three independent variables:
• primary_server, primary_le, and primary_type
• secondary_server, secondary_le, and secondary_type
• default_server, default_le, and default_type
NOTE: For information on the default values that these variables take, refer to the Restoring
Factory Default Environment Variables
section in the
Dell Networking OS Conguration guide.
Example (all stack
units)
Dell#restore factory-defaults stack-unit all clear-all
**************************************************************
* Warning - Restoring factory defaults will delete the existing *
* startup-config and all persistent settings (stacking, fanout, etc.)*
* All the units in the stack will be split into standalone units. *
* After restoration the unit(s) will be powercycled immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
0 Success Success
1 Success Success
2 Success Success
3 Not present
4 Not present
5 Not present
Power-cycling the unit(s).
Dell#
Example (single
stack)
Dell#restore factory-defaults stack-unit 0 clear-all
**************************************************************
* Warning - Restoring factory defaults will delete the existing *
* startup-config and all persistent settings (stacking, fanout, etc.)*
* After restoration the unit(s) will be powercycled immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
0 Success Success
Power-cycling the unit(s).
Dell#
Example (NvRAM all
stack units)
Dell#restore factory-defaults stack-unit all nvram
**************************************************************
* Warning - Restoring factory defaults will delete the existing *
* persistent settings (stacking, fanout, etc.) *
* All the units in the stack will be split into standalone units. *
* After restoration the unit(s) will be powercycled immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
0 Success
1 Success
2 Success
3 Not present
4 Not present
5 Not present
File Management