Service Manual

Power-cycling the unit(s).
Dell#
Example (NvRAM,
single unit)
Dell#restore factory-defaults stack-unit 1nvram
**************************************************************
* Warning - Restoring factory defaults will delete the existing *
* persistent settings (stacking, fanout, etc.) *
* After restoration the unit(s) will be powercycled immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
1 Success
Power-cycling the unit(s).
Dell#
show boot system
Displays information about boot images currently congured on the system.
Syntax
show boot system {stack-unit | all}
Parameters
all Enter the keyword all to display the boot image information for all stack units.
stack-unit Enter the keyword stack-unit followed by a number to display boot image
information for a stack-unit.
The range is from 1 to 6.
Defaults none
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000
8.3.7.0 Introduced on the S4810.
7.7.1.0 Introduced on the C-Series and E-Series.
70
File Management