Users Guide

-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------
0 0 down UNKNOWN down 0
0 1 up AC up 6504
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
--------------------------------------------------
* 0 online 36C ok 1
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
-------------------------------------------------------------------
0 40 36 37 37 31 31 46
Dell# show environment fan
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------
0 0 up up 7021 up 7021
0 1 up up 6971 up 7072
0 2 up up 7021 up 6971
Speed in RPM
Dell#show environment pem
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
------------------------------------------------------------
0 0 down UNKNOWN down 0
0 1 up AC up 6504
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
-------------------------------------------------------------------
0 39 36 37 37 31 31 46
show inventory
Display the switch type, components (including media), and Dell Networking Operating System (OS), including hardware identication
numbers and congured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member for which
you want to display pluggable media inventory.
NOTE: This parameter is available but not supported in Dell Networking
Operating System version 8.3.11.4. Because stacking is not supported, if you
use this parameter, the output displays “Media not present or accessible”
(refer to the
Usage Information
section).
Defaults none
Command Modes CONFIGURATION
Control and Monitoring 127