Users Guide

Version Description
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Usage Information When you use the no logging on command, messages are logged only to the console.
Related Commands
logging — enable logging to the Syslog server.
logging buered — set the logging buered parameters.
logging console — set the logging console parameters.
logging monitor — set the logging parameters for the terminal connections.
logging source-interface
Specify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server.
Syntax
logging source-interface interface
To disable this command and return to the default setting, use the no logging source-interface
command.
Parameters
interface Enter the following keywords and slot/port or number information:
For a 1-GigabitEthernet interface, enter the keyword GigabitEthernet then the
slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port information.
For a Loopback interface, enter the keyword loopback then a number from 0 to
16383.
For the Management interface, enter the keyword ManagementEthernet then the
slot/port information.
For a port-channel interface, enter the keywords port-channel then the port-
channel ID.
For a Null interface, enter the keyword null then the Null interface number.
For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
Defaults Not congured.
Command Modes CONFIGURATION
Simple Network Management Protocol (SNMP) and Syslog 1437