Administrator Guide
Version Description
8.4.2.3 Added support for IPv6 sFlow collectors and agents on the E-series, C-Series, and S-
Series.
8.4.1.1 Added support for IPv6 sFlow collectors and agents on the E-series.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced S-Series Stacking.
8.1.1.0 Introduced on the E-Series.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
6.5.1.0 Expanded the no form of the command to mirror the syntax used to congure.
6.2.1.1 Introduced on the E-Series.
Usage Information
You can congure up to two sFlow collectors (IPv4 or IPv6). If two collectors are congured, trac samples are
sent to both.
The sFlow agent address is carried in a eld in SFlow packets and is used by the collector to identify the sFlow
agent.
In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the collector. It is
usually assigned the address of a loopback interface on the agent, which provides invariance. The agent address is
carried as a eld in the payload of the sFlow packets.
As part of the sFlow-MIB, if the SNMP request originates from a congured collector, Dell Networking OS returns
the corresponding congured agent IP in the MIB requests. Dell Networking OS checks to ensure that two entries
are not congured for the same collector IP with a dierent agent IP. Should that happen, Dell Networking OS
generates the following error: %Error: Different agent-addr attempted for an existing
collector.
Example
Dell(conf)# sflow collector 10.1.1.25 agent-addr 10.1.1.10 vrf management
sow enable (Global)
Enable sFlow globally.
Syntax
sflow enable
To disable sFlow, use the no sflow enable command.
Defaults Disabled.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
sFlow 1483