Administrator Guide
snmp-server enable traps
Enable SNMP traps.
Syntax
snmp-server enable traps [notification-type] [notification-option]
To disable traps, use the no snmp-server enable traps [notification-type] [notification-
option] command.
Parameters
notication-type Enter the type of notication from the following list:
notication-option For the envmon notication-type, enter one of the following optional parameters:
• cam-utilization
• fan
• supply
• temperature
For the snmp notication-type, enter one of the following optional parameters:
• authentication
• coldstart
• linkdown
• linkup
• syslog-reachable
• syslog-unreachable
Defaults Not enabled.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.12(0.0) Introduced MAC address notication traps on all the Dell Networking OS platforms.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100–ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.8(0.0) Added the following two SNMP notication options: syslog-reachable and
syslog-unreachable.
9.7(0.0) Introduced on the S6000-ON.
1500 Simple Network Management Protocol (SNMP) and Syslog