Administrator Guide

snmp-server enable traps
Enable SNMP traps.
Syntax
snmp-server enable traps [notification-type] [notification-option]
To disable traps, use the no snmp-server enable traps [notification-type] [notification-
option] command.
Parameters
notication-type Enter the type of notication from the following list:
notication-option For the envmon notication-type, enter one of the following optional parameters:
cam-utilization
fan
supply
temperature
For the snmp notication-type, enter one of the following optional parameters:
authentication
coldstart
linkdown
linkup
syslog-reachable
syslog-unreachable
Defaults Not enabled.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.12(0.0) Introduced MAC address notication traps on all the Dell Networking OS platforms.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100–ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.8(0.0) Added the following two SNMP notication options: syslog-reachable and
syslog-unreachable.
9.7(0.0) Introduced on the S6000-ON.
1500 Simple Network Management Protocol (SNMP) and Syslog