Administrator Guide

Version Description
9.1(0.0) Updated Management Ethernet output to include two global IPv6 addresses on S4810
and Z9000 and added output example showing OpenFlow instance ID.
8.3.12.1 Updated command output to support multiple IPv6 addresses on S4810.
8.3.11.4 Output expanded to support eSR4 optics in Z9000.
8.3.11.1 Introduced on the Z9000.
8.5.1.0 Added support for 4-port 40G line cards on the E-Series.
8.3.7.0 Introduced on the S4810.
8.2.1.2 Included SFP and SFP+ optics power detail in the E-Series and C-Series output.
8.2.1.0 Added support for 4093 VLANs on the E-Series. Prior releases supported 2094.
8.1.1.0 Introduced on the E-Series.
7.8.1.0 Output expanded to include SFP+ media on the C-Series.
7.6.1.0 Introduced on the S Series.
7.5.1.0 Introduced on the C-Series.
6.4.1.0 Changed the organization of the display output.
6.3.1.0 Added the Pluggable Media Type eld in the E-Series output.
Usage Information
Use the show interfaces command for details on a specic interface.
NOTE: In the CLI output, the power value is rounded to a 3-digit value. For receive/transmit power that
is less than 0.000, an snmp query returns the corresponding dbm value even though the CLI displays
as 0.000.
NOTE: After the counters are cleared, the line-rate continues to increase until it reaches the maximum
line rate. When the maximum line rate is reached, there is no change in the line-rate.
User Information
The following table describes the show interfaces command shown in the 10G example.
Line Description
TenGigabitEthernet
1/1...
Interface type and administrative and line protocol status.
Hardware is... Interface hardware information, assigned MAC address, and current address.
Pluggable media
present...
Present pluggable media wavelength, type, and rate. The error scenarios are:
Wavelength, unknown — Unable to determine the optics type
Unknown — If the wavelength is reading an error
Dell Networking allows unsupported SFP and XFP transceivers to be used, but Dell
Networking OS might not be able to retrieve some data about them. In that case, typically
when the output of this eld is “Pluggable media present, Media type is unknown, the
Medium and the XFP/SFP receive power reading data might not be present in the output.
Interface index... Displays the interface index number the SNMP uses to identify the interface.
Internet address... States whether an IP address is assigned to the interface. If an IP address is assigned,
that address is displayed.
Interfaces 675