Setup Guide

26 Dell EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
7.2 Dual switch without VLT
This example uses a four-node VxRail cluster connected to a switch pair without VLT, as shown in Figure 13.
25GbE connections
100GbE LACP connections,
ports 1/1/53-54
Rack 1
S5248F-Leaf1A S5248F-Leaf1B
LACP
1/1/20 19 18 17 1/1/17 18 19 20
VxRail node 1
VxRail node 2
VxRail node 3
VxRail node 4
Note: The jump box/DNS server, not
shown, is connected to port 1/1/9 on
each switch.
Four-node cluster connected to a switch pair without VLT
In this topology, an LACP port channel is used to connect the two switches.
The commands in the following sections are run to complete the configuration of both switches. The port
numbers used in the configuration commands correspond to those shown in Figure 13.
Note: The commands in the tables below should be entered in the order shown. All commands are provided
in the file attachments named S5248F-1A-no-vlt.txt and S5248F-1B-no-vlt.txt.