Users Guide

When you are in CONFIGURATION mode, the UP or DOWN arrows keys recall the previously-entered CONFIGURATION mode
commands.
Filtering show Command Outputs
Filter the output of a show command to display specic information by adding | [except | find | grep | no-more | save]
specified_text after the command.
The variable specified_text is the text for which you are ltering and it IS case sensitive unless you use the ignore-case sub-
option.
Starting with Dell Networking OS version 7.8.1.0, the grep command accepts an ignore-case sub-option that forces the search to
case-insensitive. For example, the commands:
show run | grep Ethernet returns a search result with instances containing a capitalized “Ethernet,” such as interface
GigabitEthernet 1/1.
show run | grep ethernet does not return that search result because it only searches for instances containing a non-
capitalized “ethernet.
show run | grep Ethernet ignore-case returns instances containing both “Ethernet” and “ethernet.
The grep command displays only the lines containing specied text. The following example shows this command used in combination with
the show system brief command.
Example of the grep Keyword
Dell(conf)#do show system brief | grep 0
0 not present
NOTE
: Dell Networking OS accepts a space or no space before and after the pipe. To lter a phrase with spaces, underscores, or
ranges, enclose the phrase with double quotation marks.
The except keyword displays text that does not match the specied text. The following example shows this command used in
combination with the
show system brief command.
Example of the except Keyword
Dell#show system brief | except 1
Stack MAC : 4c:76:25:e5:49:40
Reload-Type : normal-reload [Next boot : normal-reload]
The find keyword displays the output of the show command beginning from the rst occurrence of specied text. The following example
shows this command used in combination with the show system brief command.
Example of the find Keyword
Dell#show system brief | find 0
Stack MAC : 00:11:12:13:18:20
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
1 Management online S3048-ON S3048-ON 9-8(0-28) 52
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
38
Conguration Fundamentals