Administrator Guide

Example of a Syslog
In the above example, stack unit 1 is the master management unit, stack unit 2 is the standby unit. The cables are connected to each unit.
Congure the stack groups on the units in the following order:
Congure the rst stack group on unit 1: stack-unit 1 stack-group 1
Congure the stack groups on unit 2: stack-unit 2 stack-group 0 and stack-unit 2 stack-group 1
Congure the stack groups on unit 3: stack-unit 3 stack-group 0 and stack-unit 3 stack-group 1
Congure the stack groups on unit 4: stack-unit 4 stack-group 1 and stack-unit 4 stack-group 1
Congure the nal stack-group on unit 1 to complete the stack: stack-unit 1 stack-group 0
When the stack-group conguration is complete, the system prints a syslog for reload.
Dell#configure
Dell(conf)#stack-unit 4 stack-group 0
Dell(conf)#02:39:12: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Te 4/49 have been
configured as
stacking ports. Please save and reload for config to take effect
Dell(conf)#stack-unit 4 stack-group 1
Dell(conf)#02:39:15: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 4/50 have been
configured as
stacking ports. Please save and reload for config to take effect
Dell(conf)#
Dell#02:39:18: %STKUNIT4-M:CP %SYS-5-CONFIG_I: Configured from console
Reload each unit in the stack. After the reload is complete, the four units come up as a stack with unit 1 as the management unit, unit 2 as
the standby unit, and the remaining units as stack-members. All units in the stack can be accessed from the management unit.
NOTE
: Before executing show commands, you must wait for 10 to 15 seconds for the download-agent process to start.
To view the stack unit information after the reload, use the show system brief command.
Dell#show system brief
Stack MAC : 00:01:e8:8c:53:32
Reload Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-----------------------------------------------------------------------
1 Standby online S3048-ON S3048-ON 9.8(0.0P2) 52
2 Management online S3048-ON S3048-ON 9.8(0.0P2) 52
3 Member online S3048-ON S3048-ON 9.8(0.0P2) 52
4 Member online S3048-ON S3048-ON 9.8(0.0P2) 52
5 Member not present
6 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------
1 1 up AC up 8000
1 2 absent absent 0
2 1 up AC up 8160
2 2 absent absent 0
3 1 up AC up 8000
3 2 absent absent 0
4 1 up AC up 8160
4 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed
-----------------------------------------
1 1 up up 7200
1 2 up up 7200
1 3 up up 7200
2 1 up up 7200
808