Administrator Guide
copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port
is the monitored port (MD) and the destination port is the monitoring port (MG).
deny tcp (for IPv6 ACLs)
Congure a lter that drops TCP packets that match the lter criteria.
Syntax
deny tcp {source address mask | any | host ipv6-address} [operator port [port]]
{destination address | any | host ipv6-address} [bit] [operator port [port]]
[count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor]
To remove this lter, you have two choices:
• Use the no seq sequence-number command syntax if you know the lter’s sequence number
•
Use the no deny tcp {source address mask | any | host ipv6-address}
{destination address | any | host ipv6-address} command
Parameters
source address
mask
Enter a network mask in /prex format (/x).
any Enter the keyword any to specify that all routes are subject to the lter.
host ipv6-address Enter the keyword host then the IP address to specify a host IP address.
destination address Enter the IPv6 address of the network or host to which the packets are sent.
bit Enter a ag or combination of bits:
• ack: acknowledgement eld
• fin: nish (no more data from the user)
• psh: push function
• rst: reset the connection
• syn: synchronize sequence numbers
• urg: urgent eld
operator (OPTIONAL) Enter one of the following logical operand:
• eq = equal to
• neq = not equal to
• gt = greater than
• lt = less than
• range = inclusive range of ports (you must specify two ports for the port parameter)
port port Enter the application layer port number. Enter two port numbers if you are using the
range logical operand. The range is from 0 to 65535.
The following list includes some common TCP port numbers:
• 23 = Telnet
• 20 and 21 = FTP
• 25 = SMTP
• 169 = SNMP
310 Access Control Lists (ACL)