Administrator Guide

copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port
is the monitored port (MD) and the destination port is the monitoring port (MG).
deny tcp (for IPv6 ACLs)
Congure a lter that drops TCP packets that match the lter criteria.
Syntax
deny tcp {source address mask | any | host ipv6-address} [operator port [port]]
{destination address | any | host ipv6-address} [bit] [operator port [port]]
[count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor]
To remove this lter, you have two choices:
Use the no seq sequence-number command syntax if you know the lter’s sequence number
Use the no deny tcp {source address mask | any | host ipv6-address}
{destination address | any | host ipv6-address} command
Parameters
source address
mask
Enter a network mask in /prex format (/x).
any Enter the keyword any to specify that all routes are subject to the lter.
host ipv6-address Enter the keyword host then the IP address to specify a host IP address.
destination address Enter the IPv6 address of the network or host to which the packets are sent.
bit Enter a ag or combination of bits:
ack: acknowledgement eld
fin: nish (no more data from the user)
psh: push function
rst: reset the connection
syn: synchronize sequence numbers
urg: urgent eld
operator (OPTIONAL) Enter one of the following logical operand:
eq = equal to
neq = not equal to
gt = greater than
lt = less than
range = inclusive range of ports (you must specify two ports for the port parameter)
port port Enter the application layer port number. Enter two port numbers if you are using the
range logical operand. The range is from 0 to 65535.
The following list includes some common TCP port numbers:
23 = Telnet
20 and 21 = FTP
25 = SMTP
169 = SNMP
310 Access Control Lists (ACL)