Concept Guide
Uncompressed Compressed
interface Vlan 100
no ip address
no shutdown
!
interface Vlan 1000
ip address 1.1.1.1/16
no shutdown
Uncompressed cong size – 52 lines
write memory compressed
The write memory compressed CLI will write the operating conguration to the startup-cong le in the compressed mode. In stacking
scenario, it will also take care of syncing it to all the standby and member units.
The following is the sample output:
DellEMC#write memory compressed
!
Jul 30 08:50:26: %STKUNIT0-M:CP %FILEMGR-5-FILESAVED: Copied running-config to startup-config
in flash by default
copy compressed-cong
Copy one le, after optimizing and reducing the size of the conguration le, to another location. Dell EMC Networking OS supports IPv4
and IPv6 addressing for FTP, TFTP, and SCP (in the hostip eld).
Managing the File System
The Dell EMC Networking system can use the internal Flash, external Flash, or remote devices to store les.
The system stores les on the internal Flash by default but can be congured to store les elsewhere.
To view le system information, use the following command.
• View information about each le system.
EXEC Privilege mode
show file-systems
The output of the show file-systems command in the following example shows the total capacity, amount of free memory, le
structure, media type, read/write privileges for each storage device in use.
DellEMC#show file-systems
Size(b) Free(b) Feature Type Flags Prefixes
520962048 213778432 dosFs2.0 USERFLASH rw flash:
127772672 21936128 dosFs2.0 USERFLASH rw slot0:
- - - network rw ftp:
- - - network rw tftp:
- - - network rw scp:
You can change the default le system so that le management commands apply to a particular device or memory.
To change the default directory, use the following command.
Getting Started