Setup Guide

DellEMC#show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
1 Gi 1/5 remote-vlan 10 rx Port N/A N/A
2 Vl 100 remote-vlan 20 rx Flow N/A N/A
3 Po 10 remote-vlan 30 both Port N/A N/A
DellEMC#
Conguring the sample Source Remote Port Mirroring
DellEMC(conf)#inte gi 1/1
DellEMC(conf-if-gi-1/1)#switchport
DellEMC(conf-if-gi-1/1)#no shutdown
DellEMC(conf-if-gi-1/1)#exit
DellEMC(conf)#interface gi 1/2
DellEMC(conf-if-gi-1/2)#switchport
DellEMC(conf-if-gi-1/2)#no shutdown
DellEMC(conf-if-gi-1/2)#exit
DellEMC(conf)#interface gi 1/3
DellEMC(conf-if-gi-1/3)#switchport
DellEMC(conf-if-gi-1/3)#no shutdown
DellEMC(conf-if-gi-1/3)#exit
DellEMC(conf)#inte vlan 10
DellEMC(conf-if-vl-10)#mode remote-port-mirroring
DellEMC(conf-if-vl-10)#tagged gi 1/1
DellEMC(conf-if-vl-10)#exit
DellEMC(conf)#inte vlan 20
DellEMC(conf-if-vl-20)#mode remote-port-mirroring
DellEMC(conf-if-vl-20)#tagged gi 1/2
DellEMC(conf-if-vl-20)#exit
DellEMC(conf)#interface vlan 30
DellEMC(conf-if-vl-30)#mode remote-port-mirroring
DellEMC(conf-if-vl-30)#tagged gi 1/3
DellEMC(conf-if-vl-30)#exit
DellEMC(conf)#monitor session 1 type rpm
DellEMC(conf-mon-sess-1)#source remote-vlan 10 dest gi 1/4
DellEMC(conf-mon-sess-1)#exit
DellEMC(conf)#monitor session 2 type rpm
DellEMC(conf-mon-sess-2)#source remote-vlan 20 destination gi 1/5
DellEMC(conf-mon-sess-2)#tagged destination gi 0/4
DellEMC(conf-mon-sess-2)#exit
DellEMC(conf)#monitor session 3 type rpm
DellEMC(conf-mon-sess-3)#source remote-vlan 30 destination gi 1/6
DellEMC(conf-mon-sess-3)#tagged destination gi 1/6
DellEMC(conf-mon-sess-3)#end
DellEMC#
DellEMC#show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
1 remote-vlan 10 gi 1/4 N/A N/A N/A N/A
2 remote-vlan 20 gi 1/5 N/A N/A N/A N/A
3 remote-vlan 30 gi 1/6 N/A N/A N/A N/A
DellEMC#
Conguring RSPAN Source Sessions to Avoid BPD Issues
When ever you congure an RPM source session, you must ensure the following to avoid BPDU issues:
616
Port Monitoring