Service Manual

Table Of Contents
View the details of the FP Devices and Hi gig ports on the stack-unit.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-1} details
Execute a specified bShell command from the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-1} execute-shell-cmd {command}
View the Multicast IPMC replication table from the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-1} ipmc-replication
View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-1} port-stats [detail]
View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-1} register
View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-11} unit {0-1} table-dump {table name}
Enabling Environmental Monitoring
The device components use environmental monitoring hardware to detect transmit power readings,
receive power readings, and temperature updates.
To receive periodic power updates, you must enable the following command.
Enable environmental monitoring.
enable optic-info-update interval
Example of the show interfaces transceiver Command
Dell#show interfaces transceiver
-- RPM Environment Status --
Slot Status Temp Voltage
------------------------------
0 active 33C ok
1 not present
Recognize an Overtemperature Condition
An overtemperature condition occurs, for one of two reasons: the card genuinely is too hot or a sensor
has malfunctioned.
Inspect cards adjacent to the one reporting the condition to discover the cause.
If directly adjacent cards are not normal temperature, suspect a genuine overheating condition.
If directly adjacent cards are normal temperature, suspect a faulty sensor.
Debugging and Diagnostics
1155