Service Manual

Table Of Contents
3/46 2/38 10 up up
3/47 2/39 10 up up
1/36 3/36 10 up up
1/37 3/37 10 up up
1/38 3/38 10 up up
1/39 3/39 10 up up
2/36 3/44 10 up up
2/37 3/45 10 up up
2/38 3/46 10 up up
2/39 3/47 10 up up
stack-2#
Remove Units or Front End Ports from a Stack
To remove units or front end ports from a stack, use the following instructions.
Removing a Unit from a Stack
Removing Front End Port Stacking
Removing a Unit from a Stack
The running-configuration and startup-configuration are synchronized on all stack units. A stack member
that is disconnected from the stack maintains this configuration.
To remove a stack member from the stack, disconnect the stacking cables from the unit. You may do this
at any time, whether the unit is powered or unpowered, online or offline.
NOTE: If you remove a unit in the middle of the daisy chain stack, the stack is split into multiple
parts and each forms a new stack according to the stacking algorithm described throughout this
chapter.
Examples of Removing a Stack Member (Before and After)
The following examples shows removing a stack member (before).
Dell#show system brief
Stack MAC : 00:01:e8:8a:df:e6
Reload Type : normal-reload
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-----------------------------------------------------
0 Management online S4810 S4810 8-3-7-13 64
1 Member online S4810 S4810 8-3-7-13 64
2 Member not present
3 Standby online S4810 S4810 8-3-7-13 64
The following examples shows removing a stack member (after).
Dell#show system brief
Stack MAC : 00:01:e8:8a:df:e6
Reload Type : normal-reload
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-------------------------------------------------------
0 Management online S4810 S4810 8-3-7-13 64
1 Member not present S4810
2 Member not present
958