Users Guide

Table Of Contents
Example
OS10# show alarms
Sq No Severity Name
Timestamp Source
----- -------- ------------------------------
--------------------------- ------
7563 critical EQM_MORE_PSU_FAULT Fri Jul 26
19:26:16 2019 /pus/1
7566 warning EQM_TML_MINOR_CROSSED Fri Jul 26
19:30:22 2019 /pus/1
7569 information L2_SERV_LACP_CMS_CPS_SEND_FAIL Fri Jul 26
19:55:40 2019 /pus/1
Supported
Releases
10.2.0E or later
show alarms acknowledged
Displays all acknowledged alarms.
Syntax
show alarms acknowledged
Parameters None
Default None
Command Mode EXEC
Usage
Information
None
Example
show alarms acknowledged
Sq No Severity Name
Timestamp Source
----- -------- ------------------------------
--------------------------- --------------
100071 warning EQM_FAN_FAULT_MINOR Tue Jul 23 13:53:47
2019 /psu/1/fan/1
100072 critical EQM_FAN_FAULT_MAJOR Tue Jul 23 13:53:47
2019 /psu/1
Supported
Releases
10.2.0E or later
show alarms details
Displays details about active alarms.
Syntax
show alarms details
Parameters None
Default None
Command Mode EXEC
Usage
Information
The output of the show alarms details command indicates if an alarm is acknowledged or not. If an
alarm is not acknowledged, the Acknowledged field is set to false and the Ack-time value is empty.
If an alarm is acknowledged, the Acknowledged field is set to true and the system displays the time
the alarm was acknowledged.
Example
Alarm is not acknowledged:
OS10# show alarms details
Troubleshoot Dell EMC SmartFabric OS10 1581