Administrator Guide
Example of the redundancy force-failover stack-unit Command
Dell#redundancy force-failover stack-unit
System configuration has been modified. Save? [yes/no]: yes
Proceed with Stack-unit hot failover [confirm yes/no]:yes
Dell#
Specifying an Auto-Failover Limit
When a non-recoverable fatal error is detected, an automatic failover occurs.
However, Dell Networking OS is congured to auto-failover only three times within any 60 minute period. You may specify a dierent auto-
failover count.
To re-enable the auto-failover-limit with its default parameters, use the redundancy auto-failover-limit command without
parameters.
• Set a dierent auto-failover count.
CONFIGURATION mode
redundancy auto-failover-limit
• Re-Enable the auto-failover-limit with its default parameters.
CONFIGURATION mode
redundancy auto-failover-limit
(no parameters)
Disabling Auto-Reboot
To disable auto-reboot, use the following command.
• Prevent a failed stack unit from rebooting after a failover.
CONFIGURATION mode
redundancy disable-auto-reboot
Manually Synchronizing Management and Standby Units
To manually synchronize Management and Standby units at any time, use the following command.
• Manually synchronize Management and Standby units.
EXEC Privilege mode
redundancy synchronize full
Pre-Conguring a Stack Unit Slot
You may also pre-congure an empty stack unit slot with a logical stack unit.
To pre-congure an empty stack unit slot, use the following command.
• Pre-congure an empty stack unit slot with a logical stack unit.
CONFIGURATION mode
stack-unit unit_id provisionS4048–ON
362
High Availability (HA)