Administrator Guide

"NOT_REACHABLE: Syslog server
10.11.226.121 (port: 9140) is not reachable" SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 =
INTEGER: 2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 00:46:13: dv-fedgov-s4810-6: %EVL-6-NOT_REACHABLE:Syslog server 10.11.226.121 (port:
9140) is not reachable
Following example shows the SNMP trap that is sent when connectivity to the syslog server is resumed:
DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (10230) 0:01:42.30 SNMPv2-MIB::snmpTrapOID.
0 = OID: SNMPv2-
SMI::enterprises.6027.3.30.1.1.2 SNMPv2-SMI::enterprises.6027.3.30.1.1 = STRING:
"REACHABLE: Syslog server
10.11.226.121 (port: 9140) is reachable"SNMPv2-SMI::enterprises.6027.3.6.1.1.2.0 = INTEGER: 2
Following is the sample audit log message that other syslog servers that are reachable receive:
Oct 21 05:26:04: dv-fedgov-s4810-6: %EVL-6-REACHABLE:Syslog server 10.11.226.121 (port: 9140)
is reachable
Troubleshooting SNMP Operation
When you use SNMP to retrieve management data from an SNMP agent on a Dell Networking router, take into account the following
behavior.
When you query an IPv4 icmpMsgStatsInPkts object in the ICMP table by using the snmpwalk command, the output for echo replies
may be incorrectly displayed. To correctly display this information under ICMP statistics, use the
show ip traffic command.
When you query an icmpStatsInErrors object in the icmpStats table by using the snmpget or snmpwalk command, the output for
IPv4 addresses may be incorrectly displayed. To correctly display this information under IP and ICMP statistics, use the show ip
traffic
command.
When you query an IPv4 icmpMsgStatsInPkts object in the ICMP table by using the snmpwalk command, the echo response output
may not be displayed. To correctly display ICMP statistics, such as echo response, use the
show ip traffic command.
Transceiver Monitoring
To retrieve and display the transceiver related parameters you can perform a snmpwalk transceiver table OID to retrieve transceiver details
as per the MIB. This enables transceiver monitoring and identication of potential issues related to the transceivers on a switch.
Ensure that SNMP is enabled on the device before running a query to retrieve the transceiver information.
Value 0.0 would be returned in case of Tx/Rx power not being supported on the optics.
Empty string would be displayed if optics are not inserted in a port.
Example of SNMP Output for Transceiver Monitoring
Dell $ snmpwalk -v1 -c public 10.16.150.210 1.3.6.1.4.1.6027.3.11.1.3.1.1 | grep 2106373
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.1.2106373 = STRING: "Stack-Unit-1 OptionalModule-3
Port-5"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.2.2106373 = STRING: "Fo 1/3/5"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.3.2106373 = STRING: "40GBASE-SR4"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.4.2106373 = STRING: "AVAGO"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.5.2106373 = STRING: "AFBR-79E4Z-D-FT1"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.6.2106373 = STRING: "750382760048"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.7.2106373 = STRING: "0.0"
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.8.2106373 = STRING: "-2.273117"
Table 104. SNMP OIDs for Transceiver Monitoring
Field (OID) Description
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.1 Device Name
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.2 Port
890 Simple Network Management Protocol (SNMP)