55 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
S4048-ON Leaf 3
S4048-ON Leaf 4
interface port-channel1
description Isilon Node 4
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 1
spanning-tree rstp edge-port
interface port-channel3
description Isilon Node 5
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 3
spanning-tree rstp edge-port
interface port-channel5
description Isilon Node 6
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 5
spanning-tree rstp edge-port
interface port-channel101
description Server 3
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 101
spanning-tree rstp edge-port
interface port-channel102
description Server 4
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 102
spanning-tree rstp edge-port
interface port-channel1
description Isilon Node 4
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 1
spanning-tree rstp edge-port
interface port-channel3
description Isilon Node 5
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 3
spanning-tree rstp edge-port
interface port-channel5
description Isilon Node 6
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 5
spanning-tree rstp edge-port
interface port-channel101
description Server 3
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 101
spanning-tree rstp edge-port
interface port-channel102
description Server 4
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 102
spanning-tree rstp edge-port